Heath Zenith SL-5514 manual Test and Adjustment, Specifications, Bottom of Sensor, Maximum Range

Page 3
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has about 1 1/2 minutes warm up period before it will detect motion. When first turned on, wait about 1 1/2 minutes.

Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.

ON-TIME

 

SENS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

MIN MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom of Sensor

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (2.4 cm) away from the lamps.

Adjust the SENSITIVITY as needed. Too much sensitivity may increase false triggering

Secure the sensor head’s

aim by tightening the clamp screw. Do not overtighten the

screw.

Set the amount of TIME you

want the lights to stay on after motion is detected (1, 5, or 10 minutes).

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

110°

8ft.

(2.4 m)

60 ft.

(18.3 m)

Maximum Range

Maximum

 

Coverage Angle

The detector is less sensitive to motion directly towards it and more sensitive to across motion.

SPECIFICATIONS

Range

Up to 60 ft.(18.3 m) [varies with

 

surrounding temperature].

Sensing Angle. . . .

Up to 110°

Electrical Load. . . .

300 watt Incandescent [150

 

Max each lamp holder].

Power Requirements. .

120 VAC, 60 Hz

Operating Modes. . .

TEST, AUTO and MANUAL

 

MODE

Time Delay

1, 5, 10 minutes

Replacement lamp. . .

T3 150W halogen maximum

 

120 VAC

HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

MotionMotion

 

Sensor

Least Sensitive

Most Sensitive

595-5730-05

Image 3
Contents Model SL-5514 FeaturesMode Switching Summary OperationBlack to Black White to White InstallationBulb Installation Mount the Light ControlMaximum Range Test and AdjustmentSpecifications Bottom of SensorSymptom Possible Cause Troubleshooting GuideNo Service Parts Available for this Product ONE Year Limited WarrantyRequisitos FuncionamientoModelo SL-5514 CaracterísticasInstale El Control De Luz InstalacionCuidado Para evitar los peligros de incendio Quemazón Instalación De BombillaAlcance Máximo Angulo de Cobertura Máxima Prueba Y AjusteEspecificaciones Parte de abajo del detectorGarantía Limitada a 1 AÑO Guia DE Investigacion DE AveriasServicio Técnico No hay piezas de servicio disponibles para este productoCaractéristiques Résumé du mode de commutationFonctionnement Modèle SL-5514Installation De L’ampoule Montage De La Commande D’ÉclairageNoir / noir Blanc /blanc Portée Angle de Essais ET RéglagesFiche Technique Bas du détecteurGarantie Limitée DE 1 AN Service TechniqueGuide DE Dépannage Aucune pièce de rechange n’est disponible pour ce produit