THERMOSTAT INDICATOR LAMPS

The red lamp marked “EM. HT.” comes on and stays on whenever the system switch is placed in Em. Ht. position. The green lamp marked “Check” will come on if there is any problem that prevents the compressor from running when it is supposed to be.

EMERGENCY HEAT POSITION

The operator of the equipment must manually place the system switch in this position. This is done when there is a known problem with the outdoor section, or when the green “Check” lamp comes on indicating a problem.

TRANSFORMER TAPS

230/208V, 1 phase and 3 phase equipment employ dual primary voltage transformers. All equipment leaves the factory wired on 240V tap. For 208V operation, reconnect from 240V to 208V tap. The acceptable operating voltage range for the 240 and 208V taps are:

TAP

RANGE

240

253 – 216

208

220 – 187

NOTE: The voltage should be measured at the field power connection point in the unit and while the unit is operating at full load (maximum amperage operating condition).

COMPRESSOR CUTOFF THERMOSTAT WIRING (5 and 10 KW)

FIGURE 9

UNIT 24V TERMINAL BOARD

REMOVE FACTORY

JUMPER Y-Y1

MIS-1188

OUTDOOR THERMOSTAT

 

 

USED AS COMPRESSOR CUTOFF

TABLE 8

5 and 10 KW

Model

KW

Volts

Phase

 

 

 

 

PH1224

0, 5, 10

230

1

 

 

 

 

PH1230

0, 5, 10

230

1

 

 

 

 

PH1236

0, 5, 10

230

1

 

 

 

 

COMPRESSOR CUTOFF THERMOSTAT and OUTDOOR THERMOSTAT WIRING

Heat pump compressor operation at outdoor temperatures below 0° F are neither desirable nor advantageous in terms of efficiency. Since most equipment at time of manufacture is not designated for any specific destination of the county and most of the equipment is installed in areas not approaching the lower outdoor temperature range, the compressor cutoffs are not factory installed.

Outdoor thermostats are available to hold off various banks of electric heat until needed as determined by outdoor temperature. The set point of either type of thermostat is variable with geographic region and sizing of the heating equipment to the structure. Utilization of the Heating Application Data and the heat loss calculation of the building are useful in determining the correct set points.

COMPRESSOR CUTOFF THERMOSTAT WIRING (15 KW ONLY)

FIGURE 10

UNIT 24V TERMINAL BOARD

REMOVE FACTORY

JUMPER Y-Y1

MIS-1189

OUTDOOR THERMOSTAT

 

 

USED AS COMPRESSOR CUTOFF

TABLE 9

15 KW ONLY

Model

KW

Volts

Phase

 

 

 

 

PH1230

15

230

1

 

 

 

 

PH1236

15

230

1

 

 

 

 

Manual 2100-344 Page 11

Image 13
Contents Models Installation Instructions Single Package Heat PumpsContents Getting Other Information and Publications Electrical Data Optional FIELD-INSTALLED Electric Heater TableGeneral Instructions Field Installed Heater Packages OptionalShipping Damage GeneralField Fabricated Curbing Air ConditioningRoof Hood Unit Model Typical Installations InstallationLocation Elevated Mounting Platforms Airflow and Service Access ClearancesRoof TOP Application Slab Mounting AT Ground Level Above 32 F Outside TemperatureAIR Filters Condensate Drain TrapMinimum Filter Recommended Model SizeWiring 24V LOW Voltage Control Circuit Wiring Main PowerThermostat Wire Size FLAHeat Pump Thermostats Subbase Description ThermostatsCompressor Cutoff Thermostat Wiring 15 KW only Thermostat Indicator LampsEmergency Heat Position Transformer TapsStart UP and Operation Three Phase Scroll Compressor Start UP InformationSequence of Operation Defrost CycleHeat Pump Control Board Service and Troubleshooting Trouble Shooting Guide Temperature Resistance Temperature Sensor Checking Temperature Sensor Check OUTSuction and Discharge Tube Brazing DiagramBrazing Return Air Model Pressure Tables CoolingPressure 100 105 110 115 HeatingWiring Diagram 4098-123 printed From CAD to get size needed Wiring Diagram 4098-124 printed From CAD to get size needed Wiring Diagram 4098-211 printed From CAD to get size needed

PH1224, PH1236, PH1230 specifications

Bard PH1230, PH1236, and PH1224 are advanced heating and cooling solutions that cater to both residential and commercial spaces. These units are engineered for efficiency, reliability, and comfort, making them ideal choices for any environment. Each model comes equipped with a host of features and technologies that set them apart in the HVAC market.

One of the primary characteristics of the Bard PH series is their compact design. These units are crafted to fit in tight spaces while still delivering powerful performance. This compact nature allows for easier installation, especially in areas where space is a constraint, such as classrooms, offices, and small living areas.

The PH1230, PH1236, and PH1224 all feature a robust and efficient heat pump system. This system allows the units to provide both heating and cooling, making them versatile options throughout the year. The heat pump technology ensures that energy consumption is minimized while maintaining optimal indoor temperatures. This leads to significant savings on energy bills, making these units both environmentally friendly and cost-effective.

Another commendable aspect of the Bard PH series is their advanced filtration system. These units are designed with air quality in mind, featuring high-efficiency filters that capture dust, allergens, and other particles. This not only improves indoor air quality but also enhances the overall comfort of the space. The filters are easily accessible and replaceable, ensuring that maintenance is straightforward and convenient.

Noise reduction technology is another significant feature of the Bard PH units. These models operate quietly, which is particularly beneficial in settings such as classrooms or offices where noise can be disruptive. The innovative design minimizes operational sound levels, creating a more peaceful environment.

Durability is at the forefront of the Bard PH series’ design. Constructed with high-quality materials, these units are built to withstand harsh weather conditions. The exterior casing is resistant to corrosion, ensuring longevity and reliable performance even in the most challenging environments.

In summary, Bard PH1230, PH1236, and PH1224 are exceptional heating and cooling solutions that blend efficiency, versatility, and durability. With features like compact design, advanced heat pump technology, efficient filtration systems, noise reduction capabilities, and robust construction, these units are well-suited for a variety of applications. Whether for residential or commercial use, the Bard PH series stands out as a top choice for anyone looking to enhance comfort and energy efficiency in their space.