Carrier 50PG03-16 installation instructions Fla

Page 10

Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet

 

NOMINAL

VOLTAGE

COMPRESSOR

 

 

 

 

ELECTRIC HEAT

POWER SUPPLY

 

DISCONNECT

 

 

RANGE

 

(EA)

 

 

POWER

 

CRSINGLE

 

SIZE

 

UNIT

POWER

 

OFM

IFM

IFM

 

 

 

 

WIRING

 

 

 

EXHAUST

 

 

 

PART NO.

 

 

50PG

SUPPLY

 

 

 

FLA

FLA

TYPE

CRHEATER

NOMINAL

 

 

 

FIG. NO.

MIN MAX

RLA

LRA

FLA

MOCP{

(Note 3)

FLA

LRA

 

VOLTS−PH−HZ

 

 

 

FLA

MCA

 

 

 

 

 

 

 

 

 

PART NO.

KW*

 

 

 

 

 

50PG03−16

200A00 Low 201A00 202A00 203A00

200A00 High 201A00 202A00

203A00

03 208/230-1-60 187 253 12.8 60 0.9 4.9

200A00 Low 201A00 202A00

203A00

1.4

200A00 High 201A00 202A00 203A00

 

 

21.8/21.8

30/30

 

21/21

73/73

 

10.8/12.5

2.3/

21.8/21.8

30/30

028A00

21/21

73/73

13

17.3/20.0

3.8/

27.8/31.1

30/35

028A00

26/29

73/73

13

26.0/30.0

5.6/

38.6/43.6

40/45

028A00

36/40

73/73

13

34.7/40.0

7.5/10.0

49.5/56.1

50/60

028A00

45/52

73/73

13

 

 

21.8/21.8

30/30

 

21/21

73/73

 

10.8/12.5

2.3/

21.8/21.8

30/30

028A00

21/21

73/73

13

17.3/20.0

3.8/

27.8/31.1

30/35

028A00

26/29

73/73

13

26.0/30.0

5.6/

38.6/43.6

40/45

028A00

36/40

73/73

13

34.7/40.0

7.5/10.0

49.5/56.1

50/60

028A00

45/52

73/73

13

 

 

23.2/23.2

30/30

 

23/23

75/75

 

10.8/12.5

2.3/

23.2/23.5

30/30

028A00

23/23

75/75

13

17.3/20.0

3.8/

29.5/32.9

30/35

028A00

27/30

75/75

13

26.0/30.0

5.6/

40.4/45.4

45/50

028A00

37/42

75/75

13

34.7/40.0

7.5/10.0

51.2/57.9

60/60

028A00

47/53

75/75

13

 

 

23.2/23.2

30/30

 

23/23

75/75

 

10.8/12.5

2.3/

23.2/23.5

30/30

028A00

23/23

75/75

13

17.3/20.0

3.8/

29.5/32.9

30/35

028A00

27/30

75/75

13

26.0/30.0

5.6/

40.4/45.4

45/50

028A00

37/42

75/75

13

34.7/40.0

7.5/10.0

51.2/57.9

60/60

028A00

47/53

75/75

13

 

 

25.0/25.0

30/30

 

24/24

96/96

 

Low

200A00

201A00

202A00

203A00

204A00

200A00

201A00

10.8/12.5

 

25.0/25.0

30/30

028A00

24/24

96/96

13

17.3/20.0

 

27.8/31.1

30/40

028A00

26/29

96/96

13

26.0/30.0

 

38.6/43.6

40/45

028A00

36/40

96/96

13

34.7/40.0

 

49.5/56.1

50/60

028A00

45/52

96/96

13

52.0/60.0

11.3/15.0

71.1/81.1

80/90

029A00

65/75

96/96

14

 

 

25.0/25.0

30/30

 

24/24

96/96

 

10.8/12.5

 

25.0/25.0

30/30

028A00

24/24

96/96

13

17.3/20.0

 

27.8/31.1

30/40

028A00

26/29

96/96

13

High

202A00

26.0/30.0

38.6/43.6

40/45

028A00

36/40

96/96

13

208/230-1-60 187 253 15.4 83 0.9 4.9

Low

04

1.4

203A00

204A00

200A00

201A00

202A00

203A00

204A00

200A00

201A00

34.7/40.0

 

49.5/56.1

50/60

028A00

45/52

96/96

13

52.0/60.0

11.3/15.0

71.1/81.1

80/90

029A00

65/75

96/96

14

 

 

26.4/26.4

40/40

 

26/26

98/98

 

10.8/12.5

 

26.4/26.4

40/40

028A00

26/26

98/98

13

17.3/20.0

 

29.5/32.9

40/40

028A00

27/30

98/98

13

26.0/30.0

 

40.4/45.4

45/50

028A00

37/42

98/98

13

34.7/40.0

 

51.2/57.9

60/60

028A00

47/53

98/98

13

52.0/60.0

11.3/15.0

72.9/82.9

80/90

029A00

67/76

98/98

14

 

 

26.4/26.4

40/40

 

26/26

98/98

 

10.8/12.5

 

26.4/26.4

40/40

028A00

26/26

98/98

13

17.3/20.0

 

29.5/32.9

40/40

028A00

27/30

98/98

13

High

202A00

26.0/30.0

40.4/45.4

45/50

028A00

37/42

98/98

13

Low

208/230-3-60 187 253 11.5 77 0.9 4.9

203A00

204A00

207A00

208A00

209A00

210A00

211A00

207A00

208A00

34.7/40.0

 

51.2/57.9

60/60

028A00

47/53

98/98

13

52.0/60.0

11.3/15.0

72.9/82.9

80/90

029A00

67/76

98/98

14

 

 

20.2/20.2

30/30

 

20/20

90/90

 

 

 

20.2/20.2

30/30

030A00

20/20

90/90

15

10.0/11.5

 

20.2/20.6

30/30

030A00

20/20

90/90

15

15.0/17.3

 

24.9/27.8

30/30

030A00

23/26

90/90

15

20.0/23.1

 

31.1/35.0

35/40

030A00

29/32

90/90

15

30.0/34.6

11.3/15.0

43.6/49.4

45/50

030A00

40/45

90/90

15

 

 

20.2/20.2

30/30

 

20/20

90/90

 

 

 

20.2/20.2

30/30

030A00

20/20

90/90

15

10.0/11.5

 

20.2/20.6

30/30

030A00

20/20

90/90

15

High

 

 

LEGEND

FLA

Full Load Amps

HACR −

Heating, Air Conditioning and Refrigeration

IFM

Indoor − Fan Motor

LRA

Locked Rotor Amps

MCA

Minimum Circuit Amps

MOCP −

Maximum Overcurrent Protection

NEC

National Electrical Code

OFM

Outdoor−Fan Motor

RLA

Rated Load Amps

209A00

210A00

211A00

15.0/17.3

 

24.9/27.8

30/30

030A00

23/26

90/90

15

20.0/23.1

 

31.1/35.0

35/40

030A00

29/32

90/90

15

30.0/34.6

11.3/15.0

43.6/49.4

45/50

030A00

40/45

90/90

15

Example: Supply voltage is 460-3-60

 

AB = 224 v

 

BC = 231 v

 

AC = 226 v

224 + 231 + 226

Average Voltage =

3

 

=681

3

=227

Determine maximum deviation from average voltage.

*Heater capacity (kW) is based on heater voltage of 208 v, 240 v, or 480 v. If power distribu- tion voltage to unit varies from rated heater voltage, heater kW will vary accordingly.

Fuse or HACR circuit breaker.

NOTES:

1.In compliance with NEC requirements for multimotor and combination load equip- ment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker.

2.Unbalanced 3-Phase Supply Voltage

Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percentage of voltage imbalance.

max voltage deviation from average voltage

% Voltage Imbalance

= 100 x

average voltage

Maximum deviation is 4 v.

Determine percent of voltage imbalance.

4

% Voltage Imbalance

= 100 x

227

= 1.76%

This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately.

3.Single point kits CRSINGLE028A00 and CRSINGLE030A00 are not required if field−supplied pressure connectors are used.

10

Image 10
Contents Installation Instructions 50PG03−16 − Block−Off Plate − Electric Heater Wire Routing CRSINGLE028A00, CRSINGLE030A00 − Single Point Box CRSINGLE033A00 − Single Point Box CRSINGLE036A00 − Heater Wiring CRSINGLE030A00 − Heater Wiring CRSINGLE035A00 FLA 221A00 10.0 14.1 030A00 222A00 13.9 15.0 20.0 Low 15.9 21.8 MIN MAX RLA LRA FLA MOCP† VOLTS−PH−HZ MCA VOLTS-PH-HZ MIN MAX RLA LRA FLA Type MCA MOCP† − Rated Load Amps Nominal Voltage Compressor Unit Range OFM Ifmf Power Supply Type Crheater Nominal Nominal Voltage Compressor OFM IFM Unit Range Power Supply FLA Type Crheater Nominal Nominal Voltage Compressor Unit Range OFM IFM Power Supply 208/230-3-60 575-3-60 VOLTS-PH-HZ RLA LRA FLA MOCP† MIN MCA MIN MAX RLA LRA FLA MCA MOCP† VOLTS-PH-HZ MIN MAX RLA LRA FLA MOCP† MCA VOLTS-PH-HZ MIN MAX RLA LRA Rated Load Amps VOLTS-PH-HZ MIN MAX RLA FLA FLA LRA Type 50PG03−16 Nominal Voltage Compressor Power Range Unit OFM IFM MIN MAX RLA LRA FLA MOCP† VOLTS-PH-HZ MCA See legend pg Compr Power OFM Catalog No50PG−16SI

50PG03-16 specifications

The Carrier 50PG03-16 is a notable air conditioning unit designed for residential and light commercial applications. This model stands out due to its combination of efficiency, durability, and innovative technology, making it a popular choice among homeowners and businesses looking for reliable cooling solutions.

One of the primary features of the Carrier 50PG03-16 is its high energy efficiency ratio (EER). This model meets or exceeds the latest environmental standards, which is essential for users looking to reduce their energy consumption and lower utility bills. The unit's efficient refrigerant cycle maximizes cooling output while minimizing energy use.

Carrier's commitment to using advanced technology is evident in the design of the 50PG03-16. The unit is equipped with a highly reliable scroll compressor, which not only operates quietly but also enhances the overall performance and longevity of the system. This type of compressor offers improvements in energy efficiency and reduces maintenance needs, providing peace of mind to the end user.

Another significant characteristic of the Carrier 50PG03-16 is its robust construction. The cabinet is fabricated from high-quality galvanized steel, ensuring durability and resistance to corrosion. This enhances the unit's lifespan and protects it from various environmental factors, which is particularly beneficial in regions with harsh weather conditions.

The ease of installation is another plus with this model. Designed with installers in mind, the Carrier 50PG03-16 simplifies the setup process, allowing for quick and efficient installation. This feature reduces overall labor costs while ensuring that the unit operates optimally from the start.

Furthermore, the Carrier 50PG03-16 offers compatibility with a variety of controls and accessories, allowing homeowners to tailor their system for maximum comfort. Users can integrate smart thermostats and zoning options, promoting enhanced control over indoor climates.

In conclusion, the Carrier 50PG03-16 air conditioning unit is a leading choice for those seeking an efficient, reliable, and durable cooling solution. With its innovative compressor technology, robust construction, and flexible installation features, it is designed to meet the demands of both residential and light commercial applications, ensuring a comfortable environment year-round.