Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX user manual Pump Pressure Adjustment

Page 8

NEVER LEAVE THE HEATER

 

NEVER LEAVE THE HEATER

 

UNATTENDED WHILE BURNING!

 

UNATTENDED WHILE BURNING!

 

 

 

 

 

H.) FUEL FILTER

10. TROUBLE SHOOTING GUIDE

CLEAN OR REPLACE TWICE A HEATING SEASON OR AS NEED.

-Remove upper shell(See 10 page).

-Remove Fan Blade(See 11 Page).

-Pull Fuel Line off from Fuel Filter Neck.

-Remove Fuel Filter.

-Wash Fuel Filter with clean kerosene and replace in tank.

-Attach Fuel Line to Fuel Filter Neck.

-Replace Fan Blade and Upper Shell.

I.) PUMP PRESSURE ADJUSTMENT

-Start Heater(See Operation, Page 8) and allow motor to reach full speed.

-Adjust Pump Pressure.(Using a Flat blade screwdriver)

Turn Relief Valve clockwise to increase pressure. Turn Relief Valve counter-clockwise to decrease pressure.

Set Pump pressure according to the chart below. -Stop Heater(See Operation, Page 8).

MODEL

PUMP PRESSURE

RMC-KFA65TDLX

3.5 psi

RMC-KFA120TDLX

4.5 psi

RMC-KFA170TDLX

6.5 psi

 

 

Figure 18. Removing Fuel Filter

Figure 19. Adjusting Pump Pressure

NOTE: USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS.

USE OF ALTERNATE OR THIRD PARTY COMPONENTS WILL VOID ANY WARRANTY AND MAY CAUSE UNSAFE OPERATING CONDITION.

13

14

Image 8
Contents USER’S Manual Contents of USER’S Manual FeaturesRisk of Indoor AIR Pollution Risk of BURNS/FIRE/EXPLOSIONUnpacking and Assembly RMC-KFA/65TDLX RMC-KFA120TDLXAssembly Kerosene 1-KOverview of Heaters Design Fueling Your HeaterOperation Ventilation OperationMaintenance Long Term Storage of Your Heater Fuel Tank DrainFuel Tank Upper Shell RemovalFAN Blades NozzleSpark Plug PhotocellPump Pressure Adjustment Clean or Replace Twice a Heating Season or AS NeedModel Pump Pressure RMC-KFA65TDLX RMC-KFA120TDLXWiring Diagram Specifications ModelAccessories Exploded Parts DrawingDescription Partno Bracket Side CoverDescription RMC-KFA120TDLX RMC-KFA170TDLXKEY Description Parts List Wheels and Handle RMC-KFA65TDLX ModelRMC-KFA120T/170TDLX Models