Dayton 2E511D, 3E219C, 3E218D specifications Description, Unpacking, General Specifications

Page 1

Operating Instructions & Parts Manual

2E510D, 2E511D, 3E218D, and 3E219C

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Dayton® Portable

Oil-Fired Heaters

Description

The Dayton models 2E510D, 2E511D, 3E218D, and 3E219C heaters are 30,000 to 150,000 Btu/Hr heaters. These heaters use Kerosene #1 fuel oil for combustion and electricity to run the motor. They are primarily intended for indoor and outdoor temporary heating of buildings under construction, alteration, or repair. They may be used in agricultural, industrial, and commercial environments.

Unpacking

1.Remove all packing items supplied with heater for shipment.

2.Remove all items from carton.

3.Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

Figure 1 – Models 2E510D and 2E511D

®

Figure 2 – Models 3E218D and 3E219C

GENERAL SPECIFICATIONS

 

Output

 

Fuel Tank Capacity

Fuel Consumption

 

Model

Rating Btu

Fuel

(U.S. Gallons)

(U.S. Gallons/Hr.)

Motor RPM

2E510D

35,000

Kerosene or No. 1 fuel oil

3.0

0.3

1725

2E511D

55,000

Kerosene or No. 1 fuel oil

5.0

0.4

1725

3E218D

110,000

Kerosene or No. 1 fuel oil

9.0

0.8

3450

3E219C

150,000

Kerosene or No. 1 fuel oil

13.5

1.1

3450

 

Hot Air

Air Pump

Shipping Weight

Heater Weight

Spark Plug Gap

Model

Output (CFM)

Pressure (PSI)

(Pounds)

(Pounds - without fuel)

(Inches)

2E510D

165

3.0

38

35

.055

2E511D

175

3.4

39

36

.075

3E218D

490

4.5

65

55

.075

3E219C

500

5.0

65

55

.075

Form 5S1792

© 1995 W.W. Grainger, Inc. Printed in U.S.A.

03430

0895/206/VCPVP

®

Version B - For Reduction

G016.J

Image 1
Contents Description General SpecificationsUnpacking Product Identification Electrical SpecificationsModels 2E510D, 2E511D, 3E218D, and 3E219C General Safety InformationFuels Theory of OperationOperation AssemblyVentilation To Start HeaterUpper Shell Removal MaintenanceTo Stop Heater To Restart HeaterAIR OUTPUT, AIR INTAKE, and Lint Filters Pump Pressure AdjustmentFuel Filter Fuel Filter Removal, Models 2E510D and 2E511D Spark PlugNozzle Attach spark plu g wire to spark plugRemoving Burner Head, Models 3E218D and 3E219C Pump RotorStoring Transporting, or Shipping Preventative Maintenance ScheduleFor Replacement Parts, call Replacement Parts List 2E510D and 2E511D Models 2E510D and 2E511D Portable Oil-Fired Heaters 3E218D Model 3E218D Portable Oil-Fired Heater 3E219C Model 3E219C Portable Oil-Fired Heater Accessories Maintenance KitsWiring Diagram for Models 2E510D and 2E511D Wiring DiagramsSee Air Output, Air Intake and Lint Troubleshooting ChartDayton Operating Instructions and Parts Manual Not a UPC