Operating Instructions & Parts Manual | 2E510D, 2E511D, 3E218D, and 3E219C |
|
|
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Dayton® Portable
Oil-Fired Heaters
Description
The Dayton models 2E510D, 2E511D, 3E218D, and 3E219C heaters are 30,000 to 150,000 Btu/Hr heaters. These heaters use Kerosene #1 fuel oil for combustion and electricity to run the motor. They are primarily intended for indoor and outdoor temporary heating of buildings under construction, alteration, or repair. They may be used in agricultural, industrial, and commercial environments.
Unpacking
1.Remove all packing items supplied with heater for shipment.
2.Remove all items from carton.
3.Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
Figure 1 – Models 2E510D and 2E511D | ® |
Figure 2 – Models 3E218D and 3E219C |
GENERAL SPECIFICATIONS
| Output |
| Fuel Tank Capacity | Fuel Consumption |
|
Model | Rating Btu | Fuel | (U.S. Gallons) | (U.S. Gallons/Hr.) | Motor RPM |
2E510D | 35,000 | Kerosene or No. 1 fuel oil | 3.0 | 0.3 | 1725 |
2E511D | 55,000 | Kerosene or No. 1 fuel oil | 5.0 | 0.4 | 1725 |
3E218D | 110,000 | Kerosene or No. 1 fuel oil | 9.0 | 0.8 | 3450 |
3E219C | 150,000 | Kerosene or No. 1 fuel oil | 13.5 | 1.1 | 3450 |
| Hot Air | Air Pump | Shipping Weight | Heater Weight | Spark Plug Gap |
Model | Output (CFM) | Pressure (PSI) | (Pounds) | (Pounds - without fuel) | (Inches) |
2E510D | 165 | 3.0 | 38 | 35 | .055 |
2E511D | 175 | 3.4 | 39 | 36 | .075 |
3E218D | 490 | 4.5 | 65 | 55 | .075 |
3E219C | 500 | 5.0 | 65 | 55 | .075 |
Form 5S1792
© 1995 W.W. Grainger, Inc. Printed in U.S.A.
03430
0895/206/VCPVP
®
Version B - For Reduction | G016.J |