Desa B600D, B350D owner manual Burner Head Assembly 350,000 and 600,000 Btu/Hr

Page 18

HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR

Burner Head Assembly 350,000 and 600,000 Btu/Hr

 

3

REF

 

 

 

 

 

NO.

PART NO.

DESCRIPTION

QTY.

 

 

1

M10908-2

Screw, #6-32 x 3/8"

 

4

1

 

 

(350,000 Btu/Hr Only)

2

 

2

099229-01

Photocell bracket

 

5

 

 

 

(350,000 Btu/Hr Only)

1

2

 

 

6

3

HA3012

Spark plug

1

 

 

 

4

M50112

Nozzle (350,000 Btu/Hr)

1

 

 

 

M30765

Nozzle (600,000 Btu/Hr)

1

7

 

5

M51170-01

Plug

1

 

 

6

M50924-02

Burner head body

1

 

8

7

69246

Straight nipple

1

 

 

9

8

M50077

Solenoid valve

1

Figure 18 - Burner Head Assembly

 

9

M50297

Compression elbow

1

 

 

 

Motor and Pump Assembly 350,000 and 600,000 Btu/Hr

REF.

 

 

 

NO.

PART NO.

DESCRIPTION

QTY.

1

097495-02AA

Wiring cover

1

2

HF5-5C

Screw, 5/16-24 x 5/16"

4

3

WLE-5

External lockwasher, 5/16"

4

4

M11084-26

Screw, #10-16 x 3/8"

3

5

099562-01

Motor (350,000 Btu/Hr)

1

 

099562-02

Motor (600,000 Btu/Hr)

1

6

M50116

Flange clamp

 

 

 

(holds pump to motor)

1

7

099520-01AA

Motor support

 

 

 

(350,000 Btu/Hr)

1

 

101552-01

Motor support

 

 

 

(600,000 Btu/Hr)

1

8

57413

Street elbow

2

9

M17499-2

Pipe nipple

1

10

098102-01

Fuel filter assembly

1

 

098103-01

Filter element

 

 

 

(inside fuel filter

 

 

 

assembly, includes

 

 

 

rubber gaskets)

1

11

M50114-02

90˚ Male elbow

1

12

M50297

Compression elbow

1

13

M50113-02

Straight fitting

1

14

098560-01

Fuel pump

1

15

**

Lockwasher, 5/16"

4

16

NPF-5C

Hex nut, 5/16-24"

4

17

HA3003

Flame-out control

1

18

097491-01

Power relay

1

19

101547-01

Snap bushing

3

20

M10908-2

Screw, #6-32 x 3/8"

2

21

101504-01

Strain relief bushing

1

22

M10908-14

Screw, #8-32 x 3/8"

1

23

099125-05

Terminal board

1

24

099125-04

Terminal board

1

25

099157-01

Rivet

2

 

 

 

 

 

1

 

 

4

 

2

 

 

3

 

 

 

5

11

 

10

 

 

 

6

9

 

 

8

 

 

14

 

12

13

 

 

20

 

8

19

 

(3)

22

 

18

 

 

 

17

21

 

 

 

7

24

15

 

23

16

 

 

 

25

(2)

Figure 19 - Motor And Pump Assembly

** Standard hardware item

18

099507

Image 18
Contents High Pressure Portable Forced AIR Heaters Safety Information FuelingProduct Identification UnpackingTheory Fuelsventilation Operation Fresh Air Opening RequirementsOpening To Start Heater Extension Cord Wire Size RequirementsStoring TRANSPORTING, or Shipping To Stop HeaterPreventative Maintenance Schedule How OftenTroubleshooting Observed Problem Possible Cause RemedyStoring, Transporting, or Shipping Adjust pump pressure see Pump Pres Spark Plug Service ProceduresUpper Shell Removal NozzlePump Pressure Adjustment Procedure if Pump is BindingPump Fuel Filters Procedure for Tightening Fuel LinesFuel Lines Tank Fuel FilterMaintenance Kits SpecificationsWiring Diagram AccessoryIllustrated Parts Breakdown Parts List Description QTY600,000 BTU/HR NPC-1C Δ Burner Head Assembly 350,000 and 600,000 Btu/Hr Motor and Pump Assembly 350,000 and 600,000 Btu/Hr099507 Parts and Repair Service Limited WarrantyParts and Service Under Warranty Corporate Headquarters

B350D, B600D specifications

The Desa B350D and B600D are two cutting-edge heating appliances designed to meet modern demands for efficiency, performance, and user convenience. These models, known for their reliable heating capabilities, incorporate advanced technologies that enhance both functionality and comfort in various environments.

The Desa B350D is a mid-range option that is ideal for smaller spaces. It boasts a compact design that allows it to fit seamlessly into any room, while still delivering substantial heating power. The B350D features an adjustable thermostat, which gives users complete control over their heating needs. With a maximum output of 35,000 BTUs, it can effectively heat areas up to approximately 1,200 square feet. The unit is equipped with an innovative multi-fuel system that allows it to operate on natural gas, propane, or liquid fuel, providing versatility and convenience to users.

On the other hand, the Desa B600D is a more powerful option, designed for larger spaces requiring higher heating capacities. With an output capacity of 60,000 BTUs, it efficiently warms areas up to 2,000 square feet, making it a perfect choice for workshops, garages, or large living spaces. Just like its smaller counterpart, the B600D features a user-friendly adjustable thermostat for personalized comfort.

Both models integrate safety features such as a tilt switch, which automatically shuts off the unit if it is tipped over, ensuring peace of mind when in use. Additionally, these units are designed with a durable exterior that is built to withstand the rigors of frequent usage.

Energy efficiency is a critical consideration in today's eco-conscious market, and the Desa B350D and B600D deliver on this front as well. Both models feature an efficient burner system that maximizes fuel utilization, reducing overall consumption and lowering heating costs.

In terms of maintenance, both models are designed for easy access to components, allowing users to perform routine checks and maintenance without hassle. The user manuals provide clear instructions, ensuring that even those with minimal technical expertise can keep their units in optimal working condition.

In summary, the Desa B350D and B600D stand out in the heating appliance market for their powerful performance, versatile fuel options, and user-friendly features. Whether for residential or commercial applications, these models represent a reliable choice for those seeking efficient and effective heating solutions.