Desa B600D, B350D owner manual Safety Information, Fueling

Page 2

HIGH PRESSURE PORTABLE FORCED AIR HEATER 350,000 AND 600,000 BTU/HR

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include preg- nant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.

Fueling

a)Personnel involved with fueling shall be qualified and thoroughly familiar with the manufacturer's instructions and applicable federal, state, and lo- cal regulations regarding the safe

fueling of heating units.

b)Only the type of fuel specified on the heater's data plate shall be used.

c)All flame, including the pilot light, if any, shall be extinguished and the heater allowed to cool, prior to fueling.

d)During fueling, all fuel lines and fuel- line connections shall be inspected for leaks. Any leaks shall be repaired prior to returning the heater to service.

e)At no time shall more than one day's supply of heater fuel be stored in- side a building in the vicinity of the heater. Bulk fuel storage shall be outside the structure.

f)All fuel storage shall be located a minimum of 25 feet from heaters, torches, welding equipment, and similar sources of ignition (excep- tion: the fuel reservoir integral with

the heater unit).

g)Whenever possible, fuel storage shall be confined to areas where floor penetrations do not permit fuel to drip onto or be ignited by a fire at lower elevation.

h)Fuel storage shall be in accordance with the federal, state, or local au- thority having jurisdiction.

Never use heater where gasoline, paint thinner, or other highly flammable va- pors are present.

Follow all local ordinances and codes when using heater.

Heaters used in the vicinity of tarpau- lins, canvas, or similar enclosure ma- terials shall be located a safe distance from such materials. The recommended minimum safe distance is 10 feet. It is further recommended that these enclo- sure materials be of a fire retardant na- ture. These enclosure materials shall be securely fastened to prevent them from igniting or from upsetting the heater due to wind action.

Use only in well vented areas. Before using heater, provide at least a three- square-foot opening of fresh, outside air for each 100,000 Btu/Hr of rating. This heater produces carbon monox- ide, which is listed by the State of Cali- fornia as a reproductive toxin under Proposition 65.

Use only in places free of flammable vapors or high dust content.

Use only with the electrical voltage and frequency specified on model plate.

Use only a three-prong, grounded ex- tension cord.

Minimum heater clearances from combustibles:

Outlet: 8 Ft. Sides: 4 Ft.

Top: 4 Ft. Rear: 4 Ft.

Locate heater on a stable and level surface while hot or running or a fire may occur.

When moving or storing heater, keep heater in a level position or fuel spill- age may occur.

Keep children and animals away from heater.

Unplug heater when not in use.

This heater has a built-in thermostat. Plugged-in heater may start at anytime.

Never use heater in living or sleeping areas.

Never block air inlet (rear) or air outlet (front) of heater.

Never move, handle, refuel, or service a hot, operating, or plugged-in heater.

Never attach duct work to front or rear of heater.

Warning to New York City Residents For Use Only At Construction Sites in accordance with applicable NYC codes under NYC Board of Standards and Appeals calender number 62-59-SA.

2

099507

Image 2
Contents High Pressure Portable Forced AIR Heaters Safety Information FuelingProduct Identification UnpackingOpening Theory Fuelsventilation OperationFresh Air Opening Requirements To Start Heater Extension Cord Wire Size RequirementsStoring TRANSPORTING, or Shipping To Stop HeaterPreventative Maintenance Schedule How OftenTroubleshooting Observed Problem Possible Cause RemedyStoring, Transporting, or Shipping Adjust pump pressure see Pump Pres Spark Plug Service ProceduresUpper Shell Removal NozzlePump Pump Pressure AdjustmentProcedure if Pump is Binding Fuel Filters Procedure for Tightening Fuel LinesFuel Lines Tank Fuel FilterMaintenance Kits SpecificationsWiring Diagram AccessoryIllustrated Parts Breakdown Parts List Description QTY600,000 BTU/HR NPC-1C Δ Burner Head Assembly 350,000 and 600,000 Btu/Hr Motor and Pump Assembly 350,000 and 600,000 Btu/Hr099507 Parts and Repair Service Limited WarrantyParts and Service Under Warranty Corporate Headquarters

B350D, B600D specifications

The Desa B350D and B600D are two cutting-edge heating appliances designed to meet modern demands for efficiency, performance, and user convenience. These models, known for their reliable heating capabilities, incorporate advanced technologies that enhance both functionality and comfort in various environments.

The Desa B350D is a mid-range option that is ideal for smaller spaces. It boasts a compact design that allows it to fit seamlessly into any room, while still delivering substantial heating power. The B350D features an adjustable thermostat, which gives users complete control over their heating needs. With a maximum output of 35,000 BTUs, it can effectively heat areas up to approximately 1,200 square feet. The unit is equipped with an innovative multi-fuel system that allows it to operate on natural gas, propane, or liquid fuel, providing versatility and convenience to users.

On the other hand, the Desa B600D is a more powerful option, designed for larger spaces requiring higher heating capacities. With an output capacity of 60,000 BTUs, it efficiently warms areas up to 2,000 square feet, making it a perfect choice for workshops, garages, or large living spaces. Just like its smaller counterpart, the B600D features a user-friendly adjustable thermostat for personalized comfort.

Both models integrate safety features such as a tilt switch, which automatically shuts off the unit if it is tipped over, ensuring peace of mind when in use. Additionally, these units are designed with a durable exterior that is built to withstand the rigors of frequent usage.

Energy efficiency is a critical consideration in today's eco-conscious market, and the Desa B350D and B600D deliver on this front as well. Both models feature an efficient burner system that maximizes fuel utilization, reducing overall consumption and lowering heating costs.

In terms of maintenance, both models are designed for easy access to components, allowing users to perform routine checks and maintenance without hassle. The user manuals provide clear instructions, ensuring that even those with minimal technical expertise can keep their units in optimal working condition.

In summary, the Desa B350D and B600D stand out in the heating appliance market for their powerful performance, versatile fuel options, and user-friendly features. Whether for residential or commercial applications, these models represent a reliable choice for those seeking efficient and effective heating solutions.