PRODUCT IDENTIFICATION
Top
Shell
Thermocouple
Ignitor
Electrode
Burner Tube
Piezo Ignitor Button
OFF |
|
LO | HI |
MED |
|
Valve Inlet | Control Knob | Base |
|
|
Hose/Regulator
Assembly
Figure 1 - Product Identification
UNPACKING
1.Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to valve inlet and hose/regulator assembly) for storage.
2.Remove all items from carton.
3.Check all items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
THEORY OF OPERATION
The Fuel System: The hose/regulator assembly attaches to the propane gas supply. This provides fuel to the heater.
The Ignition System: The piezo ignitor lights main burner.
The Automatic Control System: This system causes the heater to shut down if the flame goes out.
PRODUCT IDENTIFICATION | 3 |
UNPACKING | |
THEORY OF OPERATION |
|
PROPANE SUPPLY |
|
VENTILATION |
|
|
|
PROPANE SUPPLY
You must provide propane gas and propane tank(s).
Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA B149.2. Your local library or fire department will have this booklet.
This heater will operate with a
The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount.
1.The amount of propane gas in tank(s)
2.The temperature of tank(s)
The chart below shows the minimum number of
Average Temperature (°F) | Number |
At Tank Location | Of Tanks |
60° | 1 |
40° | 1 |
32° | 1 |
20° | 1 |
10° | 2 |
0° | 2 |
Less gas is vaporized at lower temperatures. Your local propane gas dealer will help you select the proper supply system.
VENTILATION
WARNING: Provide at least a 2.5 square foot opening of fresh, outside air while running heater. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.
For more information, visit www.desatech.com