Desa 40, 80, 60 owner manual Maintenance Replacement Parts, Specifications, Parts Under Warranty

Page 6

6

MAINTENANCE SPECIFICATIONS REPLACEMENT PARTS

MAINTENANCE

REPLACEMENT PARTS

WARNING: Never attempt to service heater while it is connected to propane supply, operating, or hot. Severe burns can occur.

1.Keep heater clean.

2.Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak that must be corrected. Correct all leaks at once.

3.Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace.

4.Have heater inspected yearly by a qualified service person.

WARNING: Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replace- ment parts could cause serious or fatal injuries. This will also protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Cen- tral or call DESA International’s Technical Service Department at 1-866-672-6040.

When calling DESA International, have ready

SPECIFICATIONS

 

Rating (Btu/Hr)

 

High

80,000

Medium

60,000

Low

40,000

Fuel

Propane Vapor Only

Fuel Consumption

 

Gallons/Hour

High 0.87, Low 0.44

Pounds/Hour

High 3.71, Low 1.86

Supply Pressure (To Regulator)

 

Maximum

200 psi

Minimum, for input adjustment ...

20 psi

Manifold Pressure (inches of water column)

High

18

Low

23.8

Ignitor Gap

0.195"

Minimum Temperature

-20ºF (-29ºC) Surrounding

 

Air Temperature

Size - L x W x H (Inches)

 

Heater

15 x 16 x 20

Carton

18 x 18.75 x 20.75

Weight (Pounds)

 

Heater

13

Carton

17

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

purchase date

In most cases, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Cen- tral or call DESA International at 1-866-672-6040 for referral information.

When calling DESA International, have ready

model number of your heater

the replacement part number

For morevisit www..com

103385-01F

Image 6
Contents Table of Contents Propane Construction TM Convection HeaterSafety Information Theory of Operation Product IdentificationUnpacking Propane SupplyInstallation OperationTo Start Heater To Stop Heater StorageFlame Patterns To Restart HeaterParts Under Warranty Maintenance Replacement PartsSpecifications Parts not Under WarrantyTroubleshooting AccessoriesIllustrated Parts Breakdown Models TC80V RCP80VParts List KEY Part Description QTY103385-01F Owners Registration Form Postage Required PROPANE/LP Forced AIR Heaters PROPANE/LP Convection Heaters GAS ChimeneasWarranty and Repair Service