Desa P)R, P)T, HRB3624 VENT-FREE Logmate Fireboxes, FB32C CIRCULATING, FB32NC, Non-Circulating

Page 43

Accessories

Continued

RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - hrc200

For all Remote-Ready Models. Allows the fire- place to be operated in a manually or thermostati- cally controlled mode. You can turn the fireplace on and off without ever leaving the comfort of your easy chair. A wall-mount docking station is included.

VENT-FREE LOGMATE® FIREBOXES

(Not Shown)

Available in 32", 36" and 42" models. Circu- lating fireboxes feature louvers and an optional blower. Non-circulating, smooth face models are ideal for custom trim applications such as stone or marble.

FB32C (CIRCULATING), FB32NC

(NON-CIRCULATING) SERIES Fireboxes

(Not Shown)

For 18" and 24" log models.

FB36CA, FB42C SERIES CIRCULATING), FB36NCA, FB42NC SERIES fireboxes

(NON-CIRCULATING)

(Not Shown) For all log models.

RECEIVER AND HAND-HELD REMOTE CONTROL KIT - HRC100

For all Remote-Ready Models. Allows the fire- place to be turned on and off by using a hand-held remote control. A wall-mount docking station is included.

WALL-MOUNT THERMOSTAT SWITCH - GWMT1

(Not Shown)

For all Remote-Ready Models. The desired com- fort setting can be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected.

WALL-MOUNT ON/OFF SWITCH GWMS2

(Not Shown)

For all Remote-Ready Models. Allows the gas log heater to be turned on and off with a wall switch.

DAMPER CLAMP - GA6080

(Not Shown)

For Remote-Ready Models. Permanently opens chimney flue damper for vented operation.

LAVA ROCK - GA6060

(Not Shown)

For all models. Order when additional rock is desired. (1.8 lb. bag)

CLEANING KIT - GCK

(Not Shown)

For all models. Your vent-free gas appliance re- quires regular cleaning and maintenance to prevent performance problems. This kit gives you the tools and instructions to make it easy to clean all critical areas of your appliance.

Information video - 108917-01

For all models. A care and maintenance video is available by calling 1-866-672-6040. You may also email your request to

productsupport@desaint.com.

Fire Crackle - CF6-A

(Not Shown)

For all models. Creates the sound of a real burn- ing fire.

119426-01A

www.desatech.com

43

Image 43
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information Unpacking Local Codes Optional Remote Control AccessoriesProduct Features Product IdentificationProviding Adequate Ventilation Air For Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Installation and Clearances For Vent-Free OperationMinimum Firebox Size Mantel Clearances If Using MantelMaterial Requirements for Distance a Safe Installation Determining Minimum Mantel Clearance When Using a HoodLog Set Floor ClearancesChimney Minimum Permanent Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round Flues DiameterPosition heater base assembly in fireplace Installation Items NeededConnect to gas supply. See Connecting To Gas Supply, External Regulator With Vent Pointing Down Connecting to GAS SupplyPropane/LP Minimum inlet pressure for purpose of input adjustmentNatural Correct all leaks at once Pressure Testing Heater Gas ConnectionsChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Remote Receiver Installing optional remote accessoriesVUL Model Logs Only Installing LogsCRB and HRB Model Logs Only Installing VUL Model Log SetsLighting Instructions For Your Safety Read Before LightingOperating Heater Thermostat-Controlled ModelsShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationRemote-Ready Models Pilot Propane/LP HRC200 Optional Hand-HeldRemote Operation Thermostat Series ModelPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Cleaning MaintenanceBurner Injector Holder and Pilot Air Inlet Hole Remote-Ready Models Only Wiring DiagramLogs Main burnerObserved Problem Possible Cause Remedy TroubleshootingPress in control knob fully Goes out when control knob isSafety interlock system has ODS/pilot lights but flameMote-Ready Models Only Tery power is low Observe minimum installaWhen heated, vapors from Turn heater off when using Battery is not installed. BatGas leak. See Warning For Masonry and Factory- built Metal Fireplace Optional Positioning Thermostat Sensing BulbThermostat-Controlled Models Only VUL18PT SpecificationsOptional Positioning of Thermostat Sensing Bulb Thermostat ModelsLog Models Illustrated Parts Breakdown and Parts ListVUL18PR, VUL24NR, VUL24PR, VUL30NR and VUL30PR 113620-01 113620-04 113620-07 Top Log #1 113620-02 113620-05 Illustrated Parts Breakdown Listed under Replacement Parts on page 42 of this manual Parts ListVUL18NR, VUL18PR, VUL24NR, VUL24PR, VUL30NR, VUL30PR Remote-Ready Variable Control ModelsNo. Part No Description Illustrated Parts Breakdown HRB3924NR Accessories Service HintsTechnical Service Replacement PartsCleaning KIT GCK Receiver and HAND-HELD Remote Control KIT HRC100WALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, HR B3624T, VUL18, VUL24, VUL30, HRB3930/3924, HRB3624, P)R specifications

Desa P)R, HRB3624, HRB3930/3924, VUL18, VUL24, VUL30, VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, and HR B3624T are part of an innovative product line designed to enhance efficiency and performance across various applications. These models showcase cutting-edge technologies and features that cater to diverse user needs.

The Desa P)R series is renowned for its robustness and reliability. Engineered with advanced materials, these models offer superior durability, making them suitable for both industrial and commercial environments. Their high-performance capabilities ensure they can handle demanding tasks without compromise.

The HRB3624 and HRB3930/3924 series provide powerful solutions with enhanced energy efficiency. Equipped with state-of-the-art motors and optimized designs, they deliver exceptional output while minimizing energy consumption. These models feature smart technology that adjusts performance based on workload, maximizing efficiency and prolonging equipment life.

VUL series, including VUL18, VUL24, and VUL30, is characterized by their versatility and user-friendly interface. These products incorporate intuitive controls, allowing for easy operation across various settings. The VUL series also features modular designs, enabling easy upgrades and maintenance to keep pace with changing requirements.

For those requiring specialized functions, the VUL 18R, VUL24R, and VUL30R models offer enhanced performance with refined specifications. These editions are optimized for high precision and are particularly suited for applications where accuracy is paramount.

The HR B3930 and HR 3924R models stand out due to their compact design without sacrificing power. Perfect for space-constrained environments, they provide a combination of high efficiency and powerful output, making them ideal for modern facilities.

The CRB3624T, VUL 18T, VUL24T, and VUL30T series incorporate advanced technology for temperature control and monitoring, ensuring optimal performance under varying conditions. These models are equipped with intelligent sensors that provide real-time feedback, allowing users to make informed adjustments.

Finally, the HR B3624T emphasizes thermal efficiency, boasting features that significantly reduce overheating risks and enhance safety. This series prioritizes user safety alongside effective performance.

In conclusion, the comprehensive features and technologies of the Desa P)R series, along with HRB and VUL models, position them as leading choices for industries seeking reliable, efficient, and versatile solutions.