Desa P)R, P)T, HRB3624, HRB3930/3924 CRB and HRB Model Logs Only, Installing VUL Model Log Sets

Page 19

Installation

Continued

6.Place middle left log over front left and bottom logs as show in Figure 26. Be sure hole in middle left log seats over pin in front left log.

Front Left Log

Rear Log

Grate

 

Bottom

Prongs

 

Log

 

Base Assembly

Front Right

 

Log

 

 

Figure 25 - Installing VUL Model Log Sets

Note: Your appliance may vary from model shown but log placement will be the same.

Middle Left Log

Middle

Right

Log

CRB and HRB Model Logs Only

1. Place bottom log in center of the base assem- bly as shown in Figure 27.

2. Rest rear log in back corner sections of base as- sembly as shown in Figure 27. Make sure log is completely vertical and not leaning in toward burner where the flame will touch the log.

3. Position front log as shown in Figure 27, making sure the grooves in the bottom of the log fit over the grate prongs.

Front Log

Bottom

Log

Base

Assembly

Figure 27 - Installing CRB and HRB Model

Log Sets

Note: Your appliance may vary from model shown but log placement will be the same.

Pin on Front

Bottom

Left Log

Log

 

Figure 26 - Installing VUL Model Log Sets

119426-01A

www.desatech.com

19

Image 19
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information Unpacking Local Codes Optional Remote Control AccessoriesProduct Features Product IdentificationProviding Adequate Ventilation Air For Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Installation and Clearances For Vent-Free OperationMinimum Firebox Size Mantel Clearances If Using MantelMaterial Requirements for Distance a Safe Installation Determining Minimum Mantel Clearance When Using a HoodLog Set Floor ClearancesChimney Minimum Permanent Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round Flues DiameterPosition heater base assembly in fireplace Installation Items NeededConnect to gas supply. See Connecting To Gas Supply, External Regulator With Vent Pointing Down Connecting to GAS SupplyPropane/LP Minimum inlet pressure for purpose of input adjustmentNatural Correct all leaks at once Pressure Testing Heater Gas ConnectionsChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Remote Receiver Installing optional remote accessoriesVUL Model Logs Only Installing LogsCRB and HRB Model Logs Only Installing VUL Model Log SetsLighting Instructions For Your Safety Read Before LightingOperating Heater Thermostat-Controlled ModelsShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationRemote-Ready Models Pilot Propane/LP HRC200 Optional Hand-HeldRemote Operation Thermostat Series ModelPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Cleaning MaintenanceBurner Injector Holder and Pilot Air Inlet Hole Remote-Ready Models Only Wiring DiagramLogs Main burnerObserved Problem Possible Cause Remedy TroubleshootingPress in control knob fully Goes out when control knob isSafety interlock system has ODS/pilot lights but flameMote-Ready Models Only Tery power is low Observe minimum installaWhen heated, vapors from Turn heater off when using Battery is not installed. BatGas leak. See Warning For Masonry and Factory- built Metal Fireplace Optional Positioning Thermostat Sensing BulbThermostat-Controlled Models Only VUL18PT SpecificationsOptional Positioning of Thermostat Sensing Bulb Thermostat ModelsLog Models Illustrated Parts Breakdown and Parts ListVUL18PR, VUL24NR, VUL24PR, VUL30NR and VUL30PR 113620-01 113620-04 113620-07 Top Log #1 113620-02 113620-05 Illustrated Parts Breakdown Listed under Replacement Parts on page 42 of this manual Parts ListVUL18NR, VUL18PR, VUL24NR, VUL24PR, VUL30NR, VUL30PR Remote-Ready Variable Control ModelsNo. Part No Description Illustrated Parts Breakdown HRB3924NR Accessories Service HintsTechnical Service Replacement PartsCleaning KIT GCK Receiver and HAND-HELD Remote Control KIT HRC100WALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, HR B3624T, VUL18, VUL24, VUL30, HRB3930/3924, HRB3624, P)R specifications

Desa P)R, HRB3624, HRB3930/3924, VUL18, VUL24, VUL30, VUL 18R, VUL24R, VUL30R, HR B3930, HR 3924R, CRB3624T, VUL 18T, VUL24T, VUL30T, and HR B3624T are part of an innovative product line designed to enhance efficiency and performance across various applications. These models showcase cutting-edge technologies and features that cater to diverse user needs.

The Desa P)R series is renowned for its robustness and reliability. Engineered with advanced materials, these models offer superior durability, making them suitable for both industrial and commercial environments. Their high-performance capabilities ensure they can handle demanding tasks without compromise.

The HRB3624 and HRB3930/3924 series provide powerful solutions with enhanced energy efficiency. Equipped with state-of-the-art motors and optimized designs, they deliver exceptional output while minimizing energy consumption. These models feature smart technology that adjusts performance based on workload, maximizing efficiency and prolonging equipment life.

VUL series, including VUL18, VUL24, and VUL30, is characterized by their versatility and user-friendly interface. These products incorporate intuitive controls, allowing for easy operation across various settings. The VUL series also features modular designs, enabling easy upgrades and maintenance to keep pace with changing requirements.

For those requiring specialized functions, the VUL 18R, VUL24R, and VUL30R models offer enhanced performance with refined specifications. These editions are optimized for high precision and are particularly suited for applications where accuracy is paramount.

The HR B3930 and HR 3924R models stand out due to their compact design without sacrificing power. Perfect for space-constrained environments, they provide a combination of high efficiency and powerful output, making them ideal for modern facilities.

The CRB3624T, VUL 18T, VUL24T, and VUL30T series incorporate advanced technology for temperature control and monitoring, ensuring optimal performance under varying conditions. These models are equipped with intelligent sensors that provide real-time feedback, allowing users to make informed adjustments.

Finally, the HR B3624T emphasizes thermal efficiency, boasting features that significantly reduce overheating risks and enhance safety. This series prioritizes user safety alongside effective performance.

In conclusion, the comprehensive features and technologies of the Desa P)R series, along with HRB and VUL models, position them as leading choices for industries seeking reliable, efficient, and versatile solutions.