Desa FGHS30NGB installation manual Ventilation AIR, Ventilation Air From Inside Building

Page 6

BLUE FLAME NATURAL GAS HEATER

AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also

Ventilation

 

Grills

Or

into Adjoining

Remove

Room,

Door into

Option 1

Adjoining

 

Room,

 

Option 3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING: Rework work- sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

12"

Figure 2 - Ventilation Air from Inside Building

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

6

107340

Image 6
Contents OWNER’S Operation and Installation Manual FGHS30NGB What to do if YOU Smell GASSafety Information Blue Flame Natural GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Locate heater where moving ve- hicle will not hit it InstallationInstallation Items Check GAS TypeInstalling Heater to Wall Installing Thermostat Sensing BulbInstalling Bottom Mounting Screws Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Connecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Turn OFF GAS To Appliance Manual Lighting ProcedureLighting Instructions Thermostat Control OperationCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atSpecifications Parts CentralsODS/Pilot Assembly Illustrated PARTS8 BreakdownThermostat Model FGHS30NGB Parts List KEY Part Number Description QTYTechnical Service Replacement PartsService Hints Service Publications Accessories107340 Warranty Information

FGHS30NGB specifications

The Desa FGHS30NGB is a leading model in the world of portable propane gas heaters, widely renowned for its exceptional performance, advanced features, and versatile applications. Designed to provide efficient heating, this model delivers warmth where it is needed most, perfect for both indoor and outdoor environments.

One of the standout features of the FGHS30NGB is its powerful heating capability, boasting an output of 30,000 BTUs. This makes it ideal for quickly warming up large spaces, whether that be a workshop, garage, or patio. The unit is designed with an adjustable heat setting, allowing users to customize their heating preferences according to their specific needs.

Another significant aspect of the FGHS30NGB is its safety features. The unit is equipped with a built-in automatic shut-off system that activates when the heater is tipped over or does not detect oxygen, ensuring peace of mind during usage. Additionally, the unit is designed with a sturdy and durable construction, making it suitable for outdoor use as well.

The FGHS30NGB incorporates modern technologies that enhance its efficiency. It features an innovative combustion system that allows for optimal fuel utilization, minimizing emissions and maximizing heat output. This not only makes it environmentally friendly but also economical for users, as they can expect reduced operational costs.

Portability is a key characteristic of the FGHS30NGB. It comes with a convenient handle and lightweight design, making it easy to transport from one location to another. Whether you're heading to a construction site or enjoying a weekend camping trip, this portable heater provides the flexibility needed for various situations.

In terms of design, the FGHS30NGB is both functional and aesthetically pleasing. Its compact size ensures it fits comfortably in tight spaces, while its modern look allows it to blend seamlessly with different decor styles.

In summary, the Desa FGHS30NGB propane heater is an excellent choice for anyone seeking reliable, efficient, and portable heating solutions. Its powerful performance, advanced safety features, and user-friendly design make it a top contender in today’s market, offering unmatched versatility for an array of heating needs.