Desa CGN10RL Inspecting Burner, Burner Flame Pattern, Pilot Flame Pattern, Shutting Off Heater

Page 11

OWNER’S MANUAL

OPERATING

HEATER

Continued

Control

KnobsBurners

OFF

PILOT

LOW

OFF

PILOT

HIGH

OFF

4.

Keep control knob pressed in for 10

BURNER FLAME PATTERN

 

seconds after pilot is lit. After 10

Figure 20 shows a correct burner flame

 

seconds, release control knob.

 

pattern. Figure 21 shows an incorrect burner

5.

Replace front panel.

flame pattern.

 

 

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pat- tern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the

thermocouple cools, the heater will shut Figure 20 - Correct Burner Flame Pattern down.

Pilot Burner

Thermocouple

Figure 17 - Burner Patterns

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

1.Turn control knob clockwise to the PILOT position.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 10, page 7).

2.Follow steps 1 through 5 under Lighting Instructions, page 10.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

GOOD PILOT

GRH/OV 009

Figure 18 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

BAD PILOT/LP

GRH/OV 008

Figure 19 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 19

turn heater off (see To Turn Off Gas to Appliance).

see Troubleshooting, pages 12 through 14.

Figure 21 - Incorrect Burner Flame Pat- tern

If burner flame pattern is incorrect, as shown in Figure 21

turn heater off (see To Turn Off Gas to Appliance).

see Troubleshooting, pages 12 through 14.

103549

11

Image 11
Contents What to do if YOU Smell GAS Infrared VENT-FREE Natural GAS HeaterUnpacking Safety InformationProduct Features Local CodesProviding Adequate Ventilation Product IdentificationAIR for Combustion and Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Heater Installing to WallInstallation Items Check GAS TypeInstalling Heater to Wall NPT Plug Tap Connecting to GAS SupplyPsig Pressure Testing Heater GAS ConnectionsPressure Testing GAS Supply Piping System Checking GAS ConnectionsOperating Heater For Your Safety Read Before LightingShutting Off Heater Inspecting BurnerBurner Flame Pattern Pilot Flame PatternObserved Problem Possible Cause SpecificationsAccessory TroubleshootingTurn control knob until it locks at desired When gas pressure is too low When gas quality is bad Technical ServiceService Hints Observed Problem Possible Cause RemedyService Publications Parts Centrals Cleaning and MaintenanceReplacement Parts Illustrated Parts Breakdown CGN10R CGN10RL KEY Part Number Description QTY Parts List CGN10R CGN10RLGAS Residential Heaters 103549 Warranty Information

CGN10RL specifications

Desa CGN10RL is a state-of-the-art gas-powered generator designed for both residential and commercial applications, offering reliability and efficiency. With a robust 10,000-watt peak output and a continuous output of 8,000 watts, this generator ensures that users can power essential appliances and tools with ease, making it an ideal choice for home emergency power, outdoor activities, and job sites.

One of the main features of the Desa CGN10RL is its powerful engine, which is designed for durability and long life. The generator utilizes a 420cc engine that is specifically engineered to provide high performance under various conditions. This engine is equipped with an automatic voltage regulator that ensures stable output, protecting connected devices from voltage fluctuations. The recoil start system provides quick and reliable starting, even in cold weather.

The CGN10RL incorporates advanced noise reduction technologies, allowing for quieter operation compared to standard generators. This is particularly beneficial in residential areas or during nighttime use, where noise levels can be a concern. The design includes a soundproofing casing that minimizes noise output while maintaining excellent ventilation for cooling.

In terms of fuel efficiency, the Desa CGN10RL has a large fuel tank capacity of 7 gallons, which provides extended run times of up to 12 hours at half load. This means less frequent refueling, which is a significant advantage for users who need sustained power for extended periods. The generator is designed to run on standard propane or natural gas, giving users flexibility in fuel choices.

The generator is also equipped with multiple outlets, including 120V and 240V options, enabling users to connect various devices simultaneously. The inclusion of a 12V DC outlet adds versatility, allowing it to charge batteries and small electronics. Furthermore, the CGN10RL features built-in circuit breakers that protect against overloads, enhancing safety for users.

Portability is another key characteristic of the Desa CGN10RL. It comes with heavy-duty wheels and a comfortable handle, making transportation to different locations effortless. Its compact design allows for easy storage when not in use.

In summary, the Desa CGN10RL generator stands out with its powerful engine, advanced noise reduction, impressive fuel efficiency, versatile output options, and portability. These features make it a reliable choice for users looking for a high-quality generator that can handle a variety of applications while maintaining ease of use and safety.