Desa CGP10TL installation manual Ing statement at, Top

Page 24

24

TROUBLE- SHOOTING

Continued

WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

Heater produces a

1.

Metal expanding while

1.

This is common with

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

just after burner is lit

 

while cooling

 

excessive, contact

or shut off

 

 

 

qualified service person

 

 

 

 

 

 

 

Heater produces

1.

Heater burning vapors

1.

Ventilate room. Stop

unwanted odors

 

from paint, hair spray,

 

using odor-causing

 

 

 

glues, etc. See IMPOR-

 

products while heater is

 

 

 

TANT statement above

 

running

 

 

2.

Low fuel supply

2.

Refill supply tank

 

 

3.

Gas leak. See Warn-

3.

Locate and correct all

 

 

 

ing statement at

 

leaks (see Checking Gas

 

 

 

top of page

 

Connections, page 14)

 

 

 

 

 

 

Heater shuts off in

1.

Not enough fresh air is

1.

Open window and/or

use (ODS operates)

 

available

 

door for ventilation

 

 

2.

Low line pressure

2.

Contact local propane/LP

 

 

 

 

 

gas company

 

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

 

nance, page 21)

 

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Locate and correct all

control knob is in

 

ing statement at

 

leaks (see Checking Gas

OFF position

 

top of page

 

Connections, page 14)

 

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during

1.

Foreign matter be-

1.

Take apart gas tubing

combustion

 

tween control valve

 

and remove foreign

 

 

 

and burner

 

matter

 

 

2.

Gas leak. See Warn-

2.

Locate and correct all

 

 

 

ing statement at

 

leaks (see Checking Gas

 

 

 

top of page

 

Connections, page 14)

 

 

 

 

 

 

Moisture/condensation

1.

Not enough combus-

1.

Refer to Air for Com-

noticed on windows

 

tion/ventilation air

 

bustion and Ventilation

 

 

 

 

 

requirements (page 5)

103575

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Local Codes Unpacking Product Features Safety DeviceProduct Identification Piezo Ignition SystemAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpacesDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Ventilation Air from OutdoorsInstallation Items Check GAS TypeLocating Heater Installing Heater to Wall Thermostat Sensing BulbMarking Screw Locations Installing Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing GAS Supply Piping System Checking GAS ConnectionsPressure Testing Heater GAS Connections Manual Shutoff ValveFor Your Safety Read Before Lighting Operating HeaterPilot Shutting Off Heater Shutting Off Burner Only pilot stays litInspecting Burner Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCleaning and Maintenance Trouble Shooting ODS/PILOT and Burner OrificeCabinet Air PassagewaysSee Cleaning TROUBLE- ShootingCleaning and Mainte Ing statement at TopTechnical Service Service HintsBreakdown Parts List CGP10T CGP10TLReplacement Parts Service Publications Accessory Parts Under WarrantyParts Not Under Warranty Valve GA5010Parts Central 103575 103575 Warranty Information Keep this Warranty