Desa CGP10TL installation manual Installing Two Mounting Screws, Folding Anchor

Page 11

INSTALLING TO WALL

Continued

Installing Two Mounting Screws

Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater.

Attaching to wall stud method

For attaching mounting screw to wall stud

1.Drill hole at marked location using 9/64" drill bit.

2.Insert mounting screw into wall stud.

3.Tighten screw until 1/16" space (thickness of penny) is between screwhead and wall.

Attaching to wall anchor method

Follow instructions below to attach mounting screws to hollow walls (wall areas between studs) or solid walls (concrete or masonry).

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep.

2.Fold wall anchor (see Figure 6).

Figure 6 - Folding Anchor

3.Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

4.For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 7). IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings.

Thin Walls

(1/4" to 1/2" thick)

Figure 7 - Popping Open Anchor Wings For Thin Walls

5.Tighten two screws until 1/16" space (thickness of penny) is between screwheads and wall (see Figure 8).

1/16" Space

Thin or Thick Wall (thick wall shown)

Solid Wall

ANCHOR

Figure 8 - Tightening Anchors

Continued 11

103575

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Information Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device Product IdentificationConfined and Unconfined Spaces AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsLocating Heater Installation ItemsCheck GAS Type Marking Screw Locations Installing Heater to WallThermostat Sensing Bulb Folding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws External Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing GAS Supply Piping SystemManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingPilot Shutting Off Burner Only pilot stays lit Shutting Off HeaterPilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternAir Passageways Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice CabinetTROUBLE- Shooting See CleaningCleaning and Mainte Top Ing statement atService Hints Technical ServiceBreakdown CGP10T CGP10TL Parts ListValve GA5010 Replacement Parts Service Publications AccessoryParts Under Warranty Parts Not Under WarrantyParts Central 103575 103575 Keep this Warranty Warranty Information