TROUBLE- SHOOTING

Continued

WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Heater produces

1.

Heater burning vapors

unwanted odors

 

from paint, hair spray,

 

 

glues, etc., (see

 

 

IMPORTANT state-

 

 

ment above).

 

2.

Gas leak. See Warn-

 

 

ing statement at

 

 

top of page

1.Ventilate room. Stop using odor-causing products while heater is running

2.Locate and correct all leaks (see Checking Gas Connections, page 14)

Heater shuts off in

1.

Not enough fresh air is

use (ODS operates)

 

available

 

2.

Low line pressure

 

3.

ODS/pilot is partially

 

 

clogged

1.Open window and/or door for ventilation

2.Contact local natural gas company

3.Clean ODS/pilot (see Cleaning and Mainte- nance, page 21)

Gas odor even when

1.

Gas leak. See Warn-

control knob is in

 

ing statement at

OFF position

 

top of page

 

2.

Control valve defec-

 

 

tive

1.Locate and correct all leaks (see Checking Gas Connections, page 14)

2.Replace control valve

Gas odor during

1.

Foreign matter be-

combustion

 

tween control valve

 

 

and burner

 

2.

Gas leak. See Warn-

 

 

ing statement at

 

 

top of page

1.Take apart gas tubing and remove foreign matter

2.Locate and correct all leaks (see Checking Gas Connections, page 14)

24

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

100847

Image 24
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information Safety Information Local Codes Unpacking Product Features Safety DeviceProduct Identification Piezo Ignition SystemFresh AIR for Combustion and Ventilation Producing Adequate VentilationUnusually Tight Construction Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation AIR Ventilation Air From OutdoorsInstallation Items Check GAS TypeLocating Heater Installing Heater to Wall Marking Screw LocationsInstalling Two Mounting Screws Folding AnchorPlacing Heater On Mounting Screws Connecting to GAS Supply Connecting Pressure Testing GAS Supply Piping SystemTo GAS Supply Checking GAS ConnectionsPressure Testing Heater GAS Connections Manual Shutoff ValveFor Your Safety Read Before Lighting Operating HeaterPilot To Select Heating Level Manual Lighting Procedure Operating Heater Inspecting BurnerTo Turn OFF GAS to Appliance Pilot Flame PatternBurner Flame Pattern Correct Burner Flame PatternCleaning and Maintenance Trouble Shooting ODS/PILOT and Burner OrificeCabinet Air PassagewaysSee Cleaning TROUBLE- ShootingMaintenance , Technical Service Ing statement atTop Service Hints Replacement Parts Parts Under WarrantyParts Not Under Warranty Service Publications Accessory Parts CentralsValve GA5010 Parts List CGN12A Illustrated Parts BreakdownWarranty Information Keep this Warranty

CGN12A specifications

Desa CGN12A represents a cutting-edge advancement in the world of generator technology, offering a perfect solution for a variety of applications, from residential use to commercial purposes. This compact and robust generator is designed to cater to users who require reliable power generation in situations where conventional electricity sources are unavailable.

One of the standout features of the Desa CGN12A is its powerful engine. The generator is equipped with a high-efficiency, four-stroke engine that ensures optimal fuel consumption while delivering impressive wattage. This reliable engine provides a maximum output of 12,000 watts, making it suitable for powering large appliances, tools, and even multiple devices at once. The impressive fuel efficiency allows users to enjoy extended operation times without frequent refueling, which is particularly advantageous during emergencies or outdoor activities.

In terms of technology, the Desa CGN12A employs a sophisticated alternator design that enhances performance stability. This ensures that the power supplied is consistent and reduces the risk of damage to sensitive electronic devices. Additionally, the generator features advanced noise-reduction technologies, allowing it to operate with lower sound levels than traditional generators, creating a more pleasant environment for users.

Portability is another key characteristic of the Desa CGN12A. The generator is designed with built-in wheels and a foldable handle, making it easy to transport from one location to another. Whether users need power for construction sites, camping trips, or tailgating events, the easy mobility of the generator makes it a practical choice.

Safety considerations have not been overlooked in the design of the CGN12A. The generator includes integrated safety features such as overload protection, which automatically shuts down the unit in case of excessive power demand. This not only protects the generator itself but also safeguards connected devices, ensuring peace of mind for users.

In conclusion, the Desa CGN12A combines power, efficiency, and portability. With its robust engine, advanced technology, and user-friendly design, it stands out as a reliable choice for anyone in need of dependable power generation. Whether for emergencies, recreational uses, or job sites, the CGN12A exemplifies the best in modern generator capabilities.