ASSEMBLY INSTRUCTIONS
Continued
DOME AND EMITTER
Gently lay heater assembly on its side using one of the shipping styrofoam inserts to prop up the top half of heater. Align holes in dome with threaded studs in emitter cover. Secure dome to emitter using three cap nuts. Tighten with an adjustable wrench. Stand heater back to upright position.
Figure 8 - Attaching Dome to Emitter
OPERATING
INSTRUCTIONS
WARNING: If you smell gas:
•Shut off gas to the appli- ance.
•Extinguish any open flames.
•If odor continues, immediately call your gas supplier.
See safety warnings and precau- tions starting on page 1 of this manual for more information.
PREPARING FOR OPERATION
1.Check heater for possible shipping damage. If any is found, immediately notify the factory.
2.Follow all safety information.
3.Check and assure control knob is in the "OFF" position.
4.Place propane/LP gas cylinder inside cylinder base. Securely connect regulator to propane/LP gas cylinder.
5.Turn cylinder valve on. Apply a soap and water solution to connection at regulator and cylinder. Bubbles forming show a leak.
6.In case of any leaks, turn off propane/LP cyl- inder valve, undo leaking connection. Check and clean connection. Reconnect regulator and leak test again.
START
1.Purge gas line leading to pilot assembly. Press and turn control knob to HIGH position, keep- ing it pressed in for 1 to 2 minutes. Note: When a new or refilled gas cylinder is installed, heater will need to be purged again.
2.To light the pilot:
a)Press control knob and turn to the PILOT position.
b)Hold control knob in and press ignition button until the pilot lights.
c)Keep control knob depressed for 30 seconds to heat thermocouple.
d)Release control knob and pilot should remain lit. Note: To visually check igni- tion of pilot, slide viewing hole cover to either side.
e)Once pilot flame stays on, close viewing hole cover.
www.desatech.com | 7 |