Desa CGD3018P installation manual If Using Mantel

Page 11

INSTALLING

Continued

Minimum Non Combustible Material Clearances

If Using Mantel

You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non combustible material behind it. Non combustible material must extend at least 8 inches up (for all models). If non combustible material is less than 12", you must install the fireplace hood acces- sory (24" and 30" models only). Even if non combustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See chart below and Figures 6 and 7 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Acces- sory for Vented Operation, page 13.

Non-Combustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Non combustible material okay.

Between 8" and 12"

24" or 30" Models: Install fireplace hood acessory

 

(GA6050 or GA6052, see Accessories, page 29).

 

18" Model: Non combustable material okay.

Less than 8"

Non combustible material must be extended to at

 

least 8". See Between 8" and 12", above. If you

 

cannot extend material, you must operate heater

 

with flue damper open.

 

 

Mantel Clearances

If you meet minimum clearance between mantel shelf and top of fireplace open- ing, a hood is not required (see Figure 6).

Mantel Shelf

10"

Underside of

 

8"

 

 

 

 

 

Mantel Shelf

 

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 1/2"

 

 

 

 

 

All minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

distances are

Minimum Non-

 

 

(A)

 

 

 

 

 

in inches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustible

 

 

 

 

 

 

 

Log Set

 

 

 

 

 

 

 

 

Material

 

 

 

 

 

 

 

 

 

 

12"

20"

241/2"

271/2"

30"

 

24"/30" Models

 

 

 

 

 

 

 

8"

14"

163/4"

181/2"

20"

 

18" Model

 

 

 

 

 

 

 

 

 

 

 

 

Top of Fireplace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opening

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

If above minimum clearances are not met, you must have a hood. Follow

minimum clearances shown in Figure 7 when using hood.

Continued

11

 

 

 

102987

Image 11
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information 001 Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device OperationUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building High traffic areas Windy or drafty areas InstallingCheck GAS Type Minimum Wall and Ceiling Clearances see Figure Minimum Fireplace ClearanceLOG Sizing Requirements Minimum Non Combustible Material Clearances If Using Mantel Floor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyAttaching Base Assembly to Fireplace Floor Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemTest Pressures Equal To or Less Than 1/2 Psig Installing Back Log #1 Installing LogsOperating Heater Variable Control Operation Operating HeaterPilot Flame Pattern Operating Heater Inspecting BurnersLogs Cleaning and Maintenance Trouble ShootingTurn off heater and let cool before cleaning ODS/PILOT and BurnerTROUBLE- Shooting Cleaning and MainteRefer to Air for Com Statement at top Trouble ShootingModel Technical ServiceService Hints Parts Central Parts Under WarrantyParts Not Under Warranty Hood GA6052 AccessoriesValve GA5010 Hood GA6050Illustrated Parts Breakdown CGD3018P CGD3924P CGD3930P Parts ListKeep this Warranty Warranty Information

CGD3018P specifications

The Desa CGD3018P is an innovative gas-fired heater designed to enhance comfort and efficiency in your home. This model combines advanced technologies with user-friendly features to deliver a reliable heating solution ideal for various spaces, including living rooms, basements, and workshops.

One of the standout features of the CGD3018P is its powerful heating capacity. With an output of up to 30,000 BTU per hour, this heater can quickly warm up a sizable area, making it perfect for those colder months when temperatures drop significantly. Its efficient heating design ensures that energy consumption remains manageable while providing heartwarming comfort.

This unit employs a modern, design-friendly aesthetic that complements a range of interior styles. The contemporary appearance is often characterized by clean lines and a sleek finish, making it an attractive addition to any room. The heater is also equipped with a built-in fan, enhancing air circulation and ensuring even heat distribution throughout the area.

The Desa CGD3018P features a thermocouple safety mechanism, which automatically shuts off the gas supply if the pilot light goes out, ensuring that safety is a top priority. Moreover, the piezo ignition system allows for quick and easy start-up, eliminating the need for matches or external ignition sources.

Adaptability is another key characteristic of this model. It can be operated using an LPG (liquefied petroleum gas) or natural gas source, making it suitable for diverse applications and user preferences. This versatility provides homeowners with the flexibility to choose their gas type based on availability and convenience.

Additionally, the heater includes adjustable heat settings, allowing users to customize their comfort levels. Whether you prefer a gentle warmth or robust heat output, the Desa CGD3018P can accommodate a range of heating needs.

Finally, the ease of installation sets this model apart. With straightforward assembly and minimal maintenance requirements, it provides hassle-free operation for homeowners looking to enhance their heating solutions. The Desa CGD3018P is undoubtedly an excellent enhancement for any space, offering both style and functionality with modern proactive safety technologies, ensuring peace of mind while keeping you warm.