INSTALLING

Continued

14

INSTALLING HEATER BASE ASSEMBLY

WARNING

WARNING ICON

G 001

You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

WARNING

WARNING ICON

G 001

If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against soot- ing. Raise fireplace floor with non-combustible material. Make sure material is secure.

CAUTION

WARNING ICON

G 001

Do not pick up heater base assembly by the burner. This could damage heater. Only handle base assembly by grates.

IMPORTANT: Make sure the heater burner is level. If heater is not level, heater will not work properly.

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose (not provided) (if allowed by local codes)

sealant resistant to propane (LP) gas, not provided

electric drill with 3/16" drill bit

1.Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11).

IMPORTANT: Hold gas regulator with wrench when connecting flexible gas hose.

2.Locate masonary screws in hardware package.

3.Position heater base assembly in fireplace.

4.Mark screw locations through holes in mounting brackets (see Figure 12, page 15). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks.

5.Remove heater base from fireplace.

6.Drill holes at marked locations using 3/16" drill bit.

7.Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 12, page 15).

8.Connect to gas supply. See Connecting To Gas Supply, page 15.

Heater Gas

Regulator

Flexible Gas Hose

Fitting

 

(if allowed by local codes)

 

Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator

102987

Image 14
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASContents Safety Information 001 Operation Local Codes Unpacking Product FeaturesSafety Device Piezo Ignition SystemUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Unconfined SpaceDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building High traffic areas Windy or drafty areas InstallingCheck GAS Type Minimum Wall and Ceiling Clearances see Figure Minimum Fireplace ClearanceLOG Sizing Requirements Minimum Non Combustible Material Clearances If Using Mantel Floor Clearances Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply Attaching Base Assembly to Fireplace FloorExternal Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Checking GAS ConnectionsTest Pressures Equal To or Less Than 1/2 Psig Installing Logs Installing Back Log #1Operating Heater Operating Heater Variable Control OperationOperating Heater Inspecting Burners Pilot Flame PatternODS/PILOT and Burner Cleaning and Maintenance Trouble ShootingTurn off heater and let cool before cleaning LogsCleaning and Mainte TROUBLE- ShootingRefer to Air for Com Trouble Shooting Statement at topModel Technical ServiceService Hints Parts Central Parts Under WarrantyParts Not Under Warranty Hood GA6050 AccessoriesValve GA5010 Hood GA6052Illustrated Parts Breakdown Parts List CGD3018P CGD3924P CGD3930PWarranty Information Keep this Warranty

CGD3018P specifications

The Desa CGD3018P is an innovative gas-fired heater designed to enhance comfort and efficiency in your home. This model combines advanced technologies with user-friendly features to deliver a reliable heating solution ideal for various spaces, including living rooms, basements, and workshops.

One of the standout features of the CGD3018P is its powerful heating capacity. With an output of up to 30,000 BTU per hour, this heater can quickly warm up a sizable area, making it perfect for those colder months when temperatures drop significantly. Its efficient heating design ensures that energy consumption remains manageable while providing heartwarming comfort.

This unit employs a modern, design-friendly aesthetic that complements a range of interior styles. The contemporary appearance is often characterized by clean lines and a sleek finish, making it an attractive addition to any room. The heater is also equipped with a built-in fan, enhancing air circulation and ensuring even heat distribution throughout the area.

The Desa CGD3018P features a thermocouple safety mechanism, which automatically shuts off the gas supply if the pilot light goes out, ensuring that safety is a top priority. Moreover, the piezo ignition system allows for quick and easy start-up, eliminating the need for matches or external ignition sources.

Adaptability is another key characteristic of this model. It can be operated using an LPG (liquefied petroleum gas) or natural gas source, making it suitable for diverse applications and user preferences. This versatility provides homeowners with the flexibility to choose their gas type based on availability and convenience.

Additionally, the heater includes adjustable heat settings, allowing users to customize their comfort levels. Whether you prefer a gentle warmth or robust heat output, the Desa CGD3018P can accommodate a range of heating needs.

Finally, the ease of installation sets this model apart. With straightforward assembly and minimal maintenance requirements, it provides hassle-free operation for homeowners looking to enhance their heating solutions. The Desa CGD3018P is undoubtedly an excellent enhancement for any space, offering both style and functionality with modern proactive safety technologies, ensuring peace of mind while keeping you warm.