Desa VS24NR VS30NR, CFS18NR, VS18NR Troubleshooting, Observed Problem Possible Cause Remedy

Page 19

OWNER’S MANUAL

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to igni-

1.

Reconnect ignitor cable

spark at ODS/pilot

 

tor cable

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

base panel.

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode positioned wrong

6.

Replace ignitor

 

7.

Ignitor electrode broken

7.

Replace ignitor

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or manual shutoff

1.

Turn on gas supply or open manual

spark at ODS/pilot but no ignition

 

valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in PI-

3.

Press in control knob while in PILOT

 

 

LOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob. Re-

 

 

 

 

peat igniting operation until air is removed

 

5.

ODS/pilot is clogged

5.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 18) or replace ODS/

 

 

 

 

pilot assembly

 

6.

Gas control setting is not correct

6.

Replace gas control

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

knob pressed in 30 seconds

 

3.

Manual shutoff valve not fully open

3.

Fully open manual shut-off valve

 

4.

Pilot flame not touching thermocouple,

4.

A) Contact local propane gas company

 

 

which allows thermocouple to cool,

 

B) Clean ODS/pilot (see Cleaning and

 

 

causing pilot flame to go out. This prob-

 

Maintenance, page 18) or replace ODS/

 

 

lem could be caused by one or both of

 

pilot assembly

 

 

the following:

 

 

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten 1/4

 

 

trol valve

 

turn more

 

6.

Thermocouple damaged

6.

Replace thermocouple

 

7.

Gas control damaged

7.

Replace gas control

www.desatech.com

Continued

103449

19

Image 19
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualDesa International Unvented Natural GAS LOG Heater Safety InformationLocal Codes Product FeaturesRemote Control Accessories Product IdentificationConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingMinimum Fireplace Clearance to Combustible Materials InstallationInstallation Clearances Check GAS TypeOperation, If Using MantelIf Not Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesChimney Minimum Permanent Height ft Flue Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig Pressure Testing Heater Gas ConnectionsPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Front Logs #1L and #1R Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS to Appliance Manual Lighting ProcedureOptional Remote Operation Shows Temperature Setting Pilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingSee Wiring Diagram, Above Gas leak. See Warning statementTechnical Service SpecificationsWiring Diagram Replacement Parts Service HintsAccessories Variable Control CFS18NR VS18NR VS24NR VS30NR Illustrated Parts BreakdownCFS18NR VS18NR VS24NR VS30NR Parts ListInternational Warranty Information