30,000 BTU/Hr
PROPANE CONSTRUCTION HEATER
STORAGE
CAUTION: Disconnect heater from propane supply tank(s).
1.Store propane tank(s) in safe manner. See Chapter 5 of Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58. Follow all lo- cal codes. Always store propane tanks outdoors.
2.Place plastic cover caps over brass fittings on inlet connector and hose/ regulator assembly.
3.Store in dry, clean, and safe place. Do not store hose/regulator assembly in- side heater combustion chamber.
4.When taking heater out of storage, al- ways check inside of heater. Insects and small animals may place foreign ob- jects in heater. Remove motor and other internal parts if needed to remove for- eign objects (see Service Procedures, page 8).
MAINTENANCE
WARNINGS
•Never service heater while it is plugged in, connected to pro- pane supply, operating, or hot. Severe burns and electrical shock can occur.
•Keep heater clear and free from combustible materials, gaso- line, and other flammable va- pors and liquids.
•Do not block the flow of com- bustion or ventilation air.
1.Keep heater clean. Clean heater annu- ally or as needed to remove dust and debris. If heater is dirty or dusty, clean heater with a damp cloth. Use house- hold cleaners on difficult spots.
2.Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once.
3.Inspect hose/regulator assembly be- fore each use. If hose is highly worn or cut, replace with hose specified by manufacturer.
4.Have heater inspected yearly by a quali- fied service agency.
5.Keep inside of heater free from com- bustible and foreign objects. Remove motor and other internal parts if needed to clean inside of heater (see Service Procedures, page 8).
6.Clean fan blades each season or as needed (see Fan, page 9).
SPECIFICATIONS
Output Rating (BTU/Hr) | 30,000 |
Fuel | Propane Vapor Only |
Fuel Consumption |
|
Gallons/Hour | .33 |
Pounds/Hour | 1.4 |
Supply Pressure To Regulator |
|
Minimum (for purposes | 20 psi |
of input adjustment) |
|
Maximum | Tank Pressure or 200 psi |
Regulator Outlet Pressure | 10 PSI |
Manifold Pressure | 10.1 PSI |
Hot Air Output |
|
(CFM Approx) | 175 |
Motor | 3045 RPM |
Electric Input | 120 volt/60 hertz |
Amperage | .6 |
Ignition | Manual, Piezo |
Weight (Pounds) |
|
Heater | 9 |
Shipping | 9.5 |
Size - L x W x H (Inches) |
|
Heater | 18.5 x 7.7 x 12.8 |
Temperature Range for Heater Operation |
*When running heater in temperatures above 85° F, high internal temperatures may cause thermal limit device to shut down heater.
6 | 104163 |