Desa BTU/HR owner manual Wiring Diagrams

Page 17

WIRING DIAGRAMS Continued

Photocell Blue

Assembly

Photocell

Ignitor

Blue Photocell

White

Ignition Control

Motor Return

AC Neutral (L2)

120V (L1)

Motor

Ignitor

White

Green Motor

Red

Black

Green

Power Plug

 

120V/60Hz

Yellow

Black

Thermostat

Yellow Ignitor

(40 Models)

Control Assembly

Photocell

Photocell

Ignitor

Motor Return

AC Neutral (L2)

Blue

Blue

Photocell

 

 

 

 

White

 

 

 

 

 

 

White

 

Green

Power Plug

 

 

 

Black

120V/60Hz

 

Green

Motor

 

 

2

 

 

 

 

 

Ignition

120V (L1)

Motor

Ignitor

Red

Black

Yellow

Yellow

1

 

 

Black

Thermostat

Ignitor

3

ON/OFF Switch

with Light

(50/55/60/70/110/115/155/165/200 Models)

Figure 37 - Wiring Diagram with Thermostat

(40/50/55/60/70/110/115/155/165/200 Models with Ignitor HA1000)

Control Assembly

Photocell

Photocell

Ignitor

Motor Return

AC Neutral (L2)

Blue

Blue

Photocell

 

 

 

 

White

 

 

 

 

 

 

White

 

Green

Power Plug

 

 

 

Black

120V/60Hz

 

Green

Motor

 

 

2

 

 

 

 

 

Ignition

120V (L1)

Motor

Ignitor

Red

Black

Tan

Tan

1

 

 

Black

Thermostat

Ignitor

3

ON/OFF Switch

with Light

Figure 38 - Wiring Diagram with Thermostat (50/55/60 Models with Ignitor 102548-08)

113282-01C

www.desatech.com

17

Image 17
Contents Table of Contents Safety Information Never attach heater to external fuel tank UnpackingProduct Identification Theory of Operation FuelsVentilation Operation AssemblyFor 110/115/155/165/200 Models only To Start HeaterOperation with Portable Generator Wthout ON/OFF SwitchStoring TRANSPORTING, or Shipping To Restart HeaterTroubleshooting Preventative Maintenance ScheduleFault Condition Possible Cause Remedy How Often How ToDirty fuel filter Ment,Obstruction in nozzle Water in fuel tankUpper Shell Removal Service ProceduresAIR OUTPUT, AIR Intake and Lint Filters FANReplace filter end cover Pump Pressure AdjustmentFuel Filter Replace combustion chamber Carefully remove replacement ignitor from packingIgnitor For 40/50/55/60/70/110/115/155/165 Models Only Nozzle AssemblyPlace plastic hex-body into vise and lightly tighten For 200 Model Only Fuel and AIR Line Replacement and Proper RoutingPump Rotor Procedure if Rotor is BindingIgnition Control Assembly SpecificationsModel Size 110/115 155 165 200Ignition Control Assembly Wiring DiagramsWiring Diagrams Standard Model Illustrated Parts BreakdownR40, REM40, PK40, UK40, TK40, N40 Thermostat ModelsModels Parts ListStandard Model NTC-4C 50/55/60/70 ModelsStandard Models WLE-2 110/115/155/165 ModelsRM200BT, B200BT, PK200T, UK200T, TK200T, REM200BT, R200BT R200B, PK200, UK200, TK200See NOZZLE/BURNER Head Assembly for 200 Models Burner Head Assembly for 110/115/155/165 ModelsFHPF3-5C Motor and Pump Assembly for 40/50/55/60/70 ModelsFHPF3-5C Motor and Pump Assembly for 110/115/155/165 ModelsMotor and Pump Assembly for 200 Models Wheels and Handle Parts List Replacement PartsParts Under Warranty Parts not Under WarrantyAccessories Technical ServiceLimited Warranty Warranty and Repair Service

BTU/HR specifications

Desa BTU/HR is an innovative energy solution that emphasizes efficiency and sustainability in thermal energy generation. Designed with the modern consumer in mind, the Desa BTU/HR platform integrates advanced technologies to optimize heating systems for both residential and commercial applications.

At its core, Desa BTU/HR operates on the principle of maximizing thermal energy while minimizing waste. This is achieved through state-of-the-art heat exchangers and combustion technologies that ensure a higher yield of usable heat per unit of fuel consumed. By utilizing a variety of inputs, including biomass, natural gas, and renewable sources, Desa BTU/HR caters to a range of energy requirements, making it versatile for diverse environments.

One distinguishing feature of the Desa BTU/HR system is its intelligent control mechanism. Equipped with smart sensors and an integrated software platform, the system continuously monitors performance and adjusts operations in real-time. This proactive management contributes to enhanced efficiency, reducing energy consumption and operational costs. Furthermore, the system allows for remote access and monitoring, enabling users to make informed decisions about their energy usage without being on-site.

Another key characteristic of the Desa BTU/HR is its modular design. This means that the system can be scaled to meet changing energy requirements without major overhauls or replacements. Businesses can start with a smaller unit and expand as needed, which is not only cost-effective but also environmentally responsible.

Desa BTU/HR prioritizes sustainability in its operations. By integrating renewable energy sources and reducing greenhouse gas emissions, the platform adheres to international standards for environmentally friendly technologies. This focus on eco-friendly practices aligns with the growing global demand for sustainable energy solutions.

In conclusion, Desa BTU/HR sets a new standard in thermal energy generation through its efficient, intelligent, and sustainable design. With features that promote optimal energy use and a commitment to reducing environmental impact, the system serves as a robust solution for heat generation in today's energy-hungry world. As the landscape of energy production continues to evolve, Desa BTU/HR stands out as a forward-thinking choice for future energy needs.