Desa MPF18VNA, MPF18VPA Inspecting Burners, Pilot Flame Pattern, ON/OFF Series Model HRC100

Page 11

OPERATING APPLIANCE

Continued

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 10.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Flip AUTO/OFF/ON switch to AUTO. Slide the selector switch to the REMOTE position (see Figure 13). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

Control Knob

REMOTE

OFF

ON

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

You can view the pilot light through the pilot view- ing hole on the pilot bracket. This is located under the front grate bar on the right side of the log set.

Figure 15 shows a correct pilot flame pattern. Figure 16 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the ther- mocouple. This will cause the thermocouple to cool. When the thermocouple cools, the appliance will shut down.

If pilot flame pattern is incorrect, as shown in Figure 16

turn appliance off (see To Turn Off Gas to Appliance), page 10

see Troubleshooting, page 13

Note: The pilot flame on natural gas units will have a slight curve but flames should be blue and have no yellow or orange color.

Thermocouple

 

 

Flame

Selector Switch in

Piezo

 

REMOTE Position

 

Adjustment

 

 

Ignitor

 

Knob

 

 

 

 

Figure 13 - Setting the Selector Switch,

Control Knob and Flame Adjustment

 

Knob for Remote Operation

ON/OFF SERIES (MODEL HRC100)

Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 14). To Lock press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed. To Unlock press both buttons together on hand- held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button

Turns Burner

On and Off

Figure 14 - On/Off Hand-Held Remote Control Unit (HRC100)

Figure 15 - Correct Pilot Flame Pattern (Your pilot may vary from pilots shown)

Thermocouple

Figure 16 - Incorrect Pilot Flame Pattern (Your pilot may vary from pilots shown)

BURNER FLAME PATTERN Figure 17 shows correct burner flame pattern.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by appliance, causing brief patches of orange flame.

Yellow Flames with Orange Streaks

Figure 17 - Correct Burner Flame Pattern

114925-01C

www.desatech.com

11

Image 11
Contents MPF24VNA, MPF24VPA MPF18VNA and MPF18VPA What to do if YOU Smell GASTable of Contents Safety Information Provide adequate clearances around air openings Local CodesHigh traffic areas Windy or drafty areas Product Identification Product FeaturesInstallation Remove log set assembly from cartonInstallation Installation and ClearancesFlue Opening Specifications Venting Specifications forInstallation Items Needed Installing ApplianceConnecting to GAS Supply Natural From Gas Meter 5 W.C.** to 10.5 W.C. Pressure Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Placement of Loose EmbersPressure Testing Appliance Gas Connections Operating Appliance Check pilot flame pattern and burner flame pat- terns often Inspecting BurnersPilot Flame Pattern ON/OFF Series Model HRC100Replacement Parts Service HintsCleaning Maintenance Technical ServiceObserved Problem Possible Cause Remedy TroubleshootingReplace burner orifice Contact local natural orPilot is lit Burner orifices clogged Propane/LP gas company Replace burner orificesControl valve defective Check manifold pressure Burners are lit Position when burners areCleaners or similar products Gas regulator defectiveGas leak. See Warning statement at top Gas leak. See WarningStatement at top Wiring Diagram SpecificationsAccessories MPF24VNA, MPF24VPA MPF18VNA, MPF18VPA Illustrated Parts BreakdownParts List Limited Warranty Vented GAS LOG Appliances Warranty InformationKeep this Warranty

MPF18VNA, MPF24VPA, MPF18VPA specifications

The Desa MPF24VPA, MPF18VPA, and MPF18VNA are innovative models designed for efficient heating solutions tailored to a variety of residential and commercial applications. These products showcase advanced technology and engineering that cater to diverse consumer needs, making them notable players in the heating equipment market.

One of the defining features of the Desa MPF series is their high heating capacity. The MPF24VPA, for instance, can deliver a robust output suitable for larger spaces, while the MPF18VPA and MPF18VNA offer slightly lower capacities, making them ideal for smaller areas. This range allows consumers to choose models according to the specific requirements of their environments.

Energy efficiency is another hallmark of the Desa MPF series. These models incorporate state-of-the-art combustion technology, ensuring maximum fuel utilization and reduced emissions. With features such as automatic ignition and efficient heat exchangers, users can expect quick heat responses and consistent comfort without wasting energy, contributing to lower utility bills.

Durability and user-friendly operation are also significant characteristics of the MPF24VPA, MPF18VPA, and MPF18VNA. Constructed with high-quality materials and components, these heaters are built to withstand the rigors of regular use. Moreover, the intuitive controls make operation straightforward, allowing users to easily adjust settings to suit their needs.

Safety is always a top priority in any heating appliance, and Desa takes this aspect seriously. The MPF series includes several safety features, such as automatic shut-off in case of overheating, low oxygen sensors, and robust construction that prevents overheating and accidental damage. These precautions ensure that consumers can enjoy their heating solutions confidently.

Additionally, the MPF series features versatile installation options. The models can be configured for vented or vent-free operation, providing flexibility based on local regulations or personal preferences. Their sleek designs are also aesthetically pleasing, allowing them to blend seamlessly into various home or office environments.

In conclusion, the Desa MPF24VPA, MPF18VPA, and MPF18VNA are exemplary heating units that combine efficiency, effectiveness, and safety. With diverse features and options designed to cater to a wide audience, these models stand out as reliable choices for anyone looking for high-quality heating solutions. Whether for a cozy home or a bustling commercial space, the Desa MPF series is engineered to deliver warmth and comfort through innovative design and technology.