SAFETY INFORMATION

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, op- erate or service this log set. Improper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon mon- oxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.

Natural & Propane/LP Gas: Natural & Propane/LP gas are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.

WARNING: Any change to this log set or its controls can be dangerous.

WARNING:Donotuseablow- erinsert,heatexchangerinsertor otheraccessorynotapprovedfor use with this appliance.

WARNING: This appliance is equipped with (natural or pro- pane/LP) gas. Field conversion is not permitted.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not place log scraps or lava rocks on burner

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Heater assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut- down. Allow surface to cool before touching.

Carefully supervise young chil- dren when they are in the room with appliance. When using the hand-held remote accessory, keep selector switch in the OFF position to prevent children from turning on burner with remote.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

114744-01B

www.desatech.com

3

Image 3
Contents SBJ24VNA, SBJ24VPA SMA24VNA, SMA24VPASBJ18VNA, SBJ18VPA SMA18VNA, SMA18VPA Table of Contents Safety Information Provide adequate clearances around air openings Product Identification Local CodesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors AIR for Combustion Ventilation InstallationCheck GAS Type Installation and Clearances for VENT-FREE OperationMinimum Noncombustible Material Clearances InstallationFloor Clearances Mantel ClearancesRound Flues Installing Damper Clamp Accessory for Vented OperationInstalling Remote Control Accessory Bracket Area of Various StandardInstalling Heater Assembly Connecting to GAS SupplyInstallation Items Needed Propane/LP From To Gas Control ValveChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Operating Heater For Your Safety Read Before LightingControl Knob and Ignitor Button Location, Manual Controlled Lighting InstructionsOptional HAND-HELD Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To ApplianceThermostat Series Model Ghrctb Manual ModeAuto Shutoff Feature Auto Thermostatic ModePilot Flame Pattern Wiring DiagramWhen Using Remote Inspecting BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleNatural Observed Problem Possible Cause Remedy TroubleshootingODS/pilot lights but flame goes Maintenance, Gas leak. See Warning Technical Service SpecificationsReplacement Parts Service HintsAccessories Illustrated Parts Breakdown Parts List SMA24VNA Shown, SMA24VPA Parts Available Not Shown Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

SMA24VNA, SBJ18VPA, SBJ24VNA, SMA18VPA, SBJ24VNA, SBJ24VPA, SMA24VNA, SMA24VPA, SBJ18VNA, SBJ18VPA, SMA18VNA, SMA18VPA specifications

Desa SMA18VPA, SMA24VNA, SBJ24VNA, SBJ24VPA, SMA24VNA, SMA24VPA, SBJ18VNA, SBJ18VPA, SMA18VNA, and SMA18VPA represent a series of advanced technologies in the field of energy production and consumption. These models are integral to the development of sustainable energy solutions and stand out for their innovative features.

One of the main features shared by all these models is their ability to optimize energy efficiency. They are designed with smart energy management systems that monitor and control energy distribution effectively. This ensures that energy consumption is minimized while maximizing output, making them ideal for both residential and commercial applications.

SMA18VPA and SMA24VNA are both characterized by high-performance inverters that convert DC electricity from solar panels into AC electricity. These models utilize cutting-edge inverter technology which increases energy yield even in partial shading conditions. Similarly, SBJ series, including SBJ24VNA and SBJ18VNA, emphasize modularity and flexibility, allowing users to expand their systems according to changing energy needs.

In terms of connectivity, these models are equipped with advanced communication protocols. This includes Wi-Fi and Ethernet options, which facilitate real-time monitoring and remote management through user-friendly mobile applications. Users can seamlessly track their energy production, consumption, and savings on their smartphones or tablets.

Another notable characteristic is the emphasis on durability and reliability. The materials used in these constructions are often weather-resistant, ensuring longevity and reducing maintenance costs over time. For instance, SMA24VPA utilizes robust casing that protects internal components from environmental damage.

Furthermore, these systems are designed to be environmentally friendly. Many of the models boast certifications that confirm their compliance with international environmental standards, promoting a sustainable approach to energy consumption.

In terms of scalability, the Desa series stands out. Users can start with a smaller setup and gradually expand as their energy needs grow. This adaptability makes these models suitable for a wide range of applications from small homes to larger industrial installations.

In conclusion, Desa SMA18VPA, SMA24VNA, SBJ24VNA, SBJ24VPA, SMA24VNA, SMA24VPA, SBJ18VNA, SBJ18VPA, SMA18VNA, and SMA18VPA are at the forefront of energy technology. With their energy efficiency, advanced connectivity features, durability, environmental responsibility, and scalability, they offer optimal solutions for modern energy demands, paving the way for a more sustainable future.