Desa SMA24VNA AIR for Combustion Ventilation Installation, Ventilation Air From Outdoors

Page 8

AIR FOR COMBUSTION

AND VENTILATION

Continued

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your

Ventilation

 

Grills

 

Into Adjoining

Or

Room,

Remove

Option 1

Door into

 

 

Adjoining

 

Room,

 

Option

 

3

12"

Ventilation Grills

Into Adjoining Room,

Option 2

primary heating system. Do not installthisheaterasyourprimary heating source. If you have a central heating system, you may run system's circulating blower while using heater. This will help circulate the heat throughout the house. In event of a power out-

12"

Figure 2 - Ventilation Air from Inside

Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat- controlled power vent. Heated air entering the attic will activate the power vent.

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

age, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

NOTICE:Stateorlocalcodesmay only allow operation of this appli- ance in a vented configuration. Check your state or local codes.

WARNING: Make sure the selector switch is in the OFF po- sition before installing heater.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creo- sote, ashes and loose paint by a qualified chimney cleaner. Creo- sote will ignite if highly heated. A dirtychimneyfluemaycreateand distribute soot within the house. Inspectchimneyfluefordamage. If damaged, repair flue damper before operating appliance.

8

www.desatech.com

114744-01B

Image 8
Contents SBJ18VNA, SBJ18VPA SMA18VNA, SMA18VPA SBJ24VNA, SBJ24VPASMA24VNA, SMA24VPA Table of Contents Safety Information Provide adequate clearances around air openings Unpacking Product IdentificationLocal Codes Determining FRESH-AIR Flow for Appliance Location AIR for Combustion VentilationProviding Adequate Ventilation Ventilation AIR Ventilation Air From Inside BuildingAIR for Combustion Ventilation Installation Ventilation Air From OutdoorsInstallation and Clearances for VENT-FREE Operation Check GAS TypeInstallation Minimum Noncombustible Material ClearancesMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Remote Control Accessory BracketArea of Various Standard Round FluesInstallation Items Needed Installing Heater AssemblyConnecting to GAS Supply To Gas Control Valve Propane/LP FromTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa For Your Safety Read Before Lighting Operating HeaterLighting Instructions Control Knob and Ignitor Button Location, Manual ControlledManual Lighting Procedure To Turn OFF GASTo Appliance Optional HAND-HELD Remote OperationManual Mode Auto Shutoff FeatureAuto Thermostatic Mode Thermostat Series Model GhrctbWiring Diagram When Using RemoteInspecting Burner Pilot Flame PatternNatural Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyODS/pilot lights but flame goes Maintenance, Gas leak. See Warning Specifications Replacement PartsService Hints Technical ServiceAccessories Illustrated Parts Breakdown Parts List SMA24VNA Shown, SMA24VPA Parts Available Not Shown Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

SMA24VNA, SBJ18VPA, SBJ24VNA, SMA18VPA, SBJ24VNA, SBJ24VPA, SMA24VNA, SMA24VPA, SBJ18VNA, SBJ18VPA, SMA18VNA, SMA18VPA specifications

Desa SMA18VPA, SMA24VNA, SBJ24VNA, SBJ24VPA, SMA24VNA, SMA24VPA, SBJ18VNA, SBJ18VPA, SMA18VNA, and SMA18VPA represent a series of advanced technologies in the field of energy production and consumption. These models are integral to the development of sustainable energy solutions and stand out for their innovative features.

One of the main features shared by all these models is their ability to optimize energy efficiency. They are designed with smart energy management systems that monitor and control energy distribution effectively. This ensures that energy consumption is minimized while maximizing output, making them ideal for both residential and commercial applications.

SMA18VPA and SMA24VNA are both characterized by high-performance inverters that convert DC electricity from solar panels into AC electricity. These models utilize cutting-edge inverter technology which increases energy yield even in partial shading conditions. Similarly, SBJ series, including SBJ24VNA and SBJ18VNA, emphasize modularity and flexibility, allowing users to expand their systems according to changing energy needs.

In terms of connectivity, these models are equipped with advanced communication protocols. This includes Wi-Fi and Ethernet options, which facilitate real-time monitoring and remote management through user-friendly mobile applications. Users can seamlessly track their energy production, consumption, and savings on their smartphones or tablets.

Another notable characteristic is the emphasis on durability and reliability. The materials used in these constructions are often weather-resistant, ensuring longevity and reducing maintenance costs over time. For instance, SMA24VPA utilizes robust casing that protects internal components from environmental damage.

Furthermore, these systems are designed to be environmentally friendly. Many of the models boast certifications that confirm their compliance with international environmental standards, promoting a sustainable approach to energy consumption.

In terms of scalability, the Desa series stands out. Users can start with a smaller setup and gradually expand as their energy needs grow. This adaptability makes these models suitable for a wide range of applications from small homes to larger industrial installations.

In conclusion, Desa SMA18VPA, SMA24VNA, SBJ24VNA, SBJ24VPA, SMA24VNA, SMA24VPA, SBJ18VNA, SBJ18VPA, SMA18VNA, and SMA18VPA are at the forefront of energy technology. With their energy efficiency, advanced connectivity features, durability, environmental responsibility, and scalability, they offer optimal solutions for modern energy demands, paving the way for a more sustainable future.