INSTALLATION VENTILATION OPERATION

To Start Heater

5

INSTALLATION

Continued

3.Connect hose to valve inlet. Tighten firmly using a wrench. You must use the regulator supplied with heater.

4.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank may stop gas flow. If this happens, close propane supply valve and open again slowly.

5.Check all connections for leaks. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak that must be corrected.

6.Close propane supply valve.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak that must be corrected. Correct all leaks at once.

 

Regulator

Propane

 

Supply

Hose

Valve

 

Propane

Fuel Gas

Tank

 

Fitting

Figure 6 - Regulator Position

 

Knob

Valve Inlet

Hose

Figure 7 - Hose and Inlet Connector

VENTILATION

WARNING: Provide at least a 1.5 square foot opening of fresh, outside air while running heater. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.

OPERATION

WARNING: Review and understand the warnings in the Safety Information section, pages 2 and 3. They are needed to safely operate this heater. Follow all local codes when using this heater.

TO START HEATER

1.Follow all installation, ventilation, and safety information.

2.Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater.

3.Plug power cord of heater into a three-prong, grounded exten- sion cord. Extension cord must be at least six feet long. Exten- sion cord must be UL listed.

Extension Cord Wire Size Requirements

Up to 50 feet long, use 18 AWG rated cord. 51 to 100 feet long, use 16 AWG rated cord. 101 to 200 feet long, use 14 AWG rated cord.

4.Plug extension cord into a 120 volt/60 hertz, 3-hole, grounded outlet. Motor will start. Fan will turn, forcing air out front of heater.

5.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank may stop gas flow. If this happens, close propane supply valve and open again slowly.

WARNING: Be sure motor and fan are running before pushingin automaticcontrol valvebutton. Flames could flash outside heater if motor and fan are not running.

6.Turn control knob to the low position and push in (see Figure 8 and 9, page 6). Hold knob in and push piezo ignitor button. You may need to push piezo ignitor button 3-8 times until the main burner lights. When main burner lights, keep automatic control valve knob pushed in. Release button after 30 seconds.

Note: If main burner fails to light, hose may have air in it. If so, keep control knob pressed and wait 20 seconds. Release control knob and wait 20 seconds for unburned fuel to exit heater. Repeat step 6.

For more information, visit www.desatech.com

105331-01C

Image 5
Contents Propane Construction TM Heater Table of ContentsSafety Information Propane Supply Product IdentificationUnpacking Theory of Operation AssemblyInstallation To Start Heater Ventilation OperationStorage MaintenanceTo Stop Heater To Restart HeaterObserved Fault Possible Cause Remedy TroubleshootingElectrical System Service ProceduresMotor FANRemoving Ignitor Mounting Screw and Ignitor IgnitorModels BLP50VA, REM50PVA RLP50VA, RM50PVA Illustrated Parts BreakdownKEY Part Description QTY Parts ListReplacement Parts SpecificationsAccessories Technical ServiceOwners Registration Form Postage Required GAS Chimeneas PROPANE/LP Forced AIR Heaters PROPANE/LP Convection HeatersWarranty and Repair Service

ROPANE CONSTRUCTION HEATER specifications

Desa Ropane Construction Heater is a powerful solution designed to provide efficient heating for construction sites, workshops, and other commercial environments. With its robust build and advanced technology, it ensures consistent warmth even in the coldest weather conditions.

One of the main features of the Desa Ropane Construction Heater is its high heat output. With various models available, users can choose units that deliver up to 200,000 BTUs, making it suitable for large spaces. This high output ensures that materials set properly and that workers remain comfortable and productive, regardless of the chilly outdoor conditions.

Another notable characteristic is its portability. The heater is designed with rugged wheels and a durable casing, allowing it to be easily maneuvered from one location to another. This feature is especially beneficial for construction sites where the heating needs may change throughout the day or the project.

The heater operates on propane, leveraging the fuel's high efficiency for longer heating durations. Its ability to quickly warm up spaces ensures that downtime is minimized, which is crucial in the fast-paced world of construction. Additionally, propane is readily available and cost-effective, making this heater an economical choice for contractors.

Desa Ropane Construction Heater also features an adjustable heat control system, allowing users to set the desired temperature according to their specific needs. This flexibility is key to optimizing energy consumption and ensuring safety, as it prevents overheating in smaller spaces.

Safety is a top priority in any heating system, and the Desa Ropane heater incorporates several built-in safety features. These include automatic shut-off mechanisms that activate in case of low oxygen levels or if the unit overheats. This provides peace of mind for users while maintaining a safe working environment.

The design of the heater also includes a directional venting system, which allows for more effective heat distribution. This system ensures that areas are warmed evenly, reducing cold spots that can lead to discomfort or inefficiencies.

In summary, the Desa Ropane Construction Heater stands out with its exceptional heat output, portability, adjustable controls, and safety features. This heater is built to cater to the specific requirements of construction and commercial spaces, providing reliable, efficient heating solutions that enhance productivity and comfort. Its combination of technology and practicality makes it a preferred choice for construction professionals across various industries.