Desa ROPANE CONSTRUCTION HEATER Storage, Maintenance, To Stop Heater, To Restart Heater

Page 6

6

OPERATION

To Start Heater (Cont.)

 

To Stop Heater

 

To Restart Heater

 

STORAGE

 

MAINTENANCE

 

 

OPERATION

Continued

7.If main burner goes out, repeat step 6, page 5.

8.When main burner remains lit, rotate control knob to the de- sired heat level.

OFF

START/

LOW

MED

HIGH

Figure 8 - Control Knob Positions

STORAGE

CAUTION: Disconnect heater from propane sup- ply tank(s).

1.Store propane tank(s) in safe manner. See Chapter 5 of Stan- dard for Storage and Handling of Liquefied Petroleum Gases, ANSI/NFPA 58. Follow all local codes. Always store propane tanks outdoors.

2.Place plastic cover caps over brass fittings on inlet connector and hose/regulator assembly.

3.Store in dry, clean, and safe place. Do not store hose/regulator assembly inside heater combustion chamber.

4.When taking heater out of storage, always check inside of heater. Insects and small animals may place foreign objects in heater. Remove motor and other internal parts if needed to re- move foreign objects (see Service Procedures, page 8).

Piezo Ignitor

Button

Automatic

Control Valve

Knob

Figure 9 - Automatic Control Valve Button and Piezo Ignitor Button

TO STOP HEATER

1.Tightly close propane supply valve on propane tank(s). Allow heater to burn remaining fuel in hose.

2.Shut off main burner valve. Do this by turning control knob to the OFF position until it stops.

TO RESTART HEATER

1.Wait five minutes after stopping heater.

2.Repeat steps under To Start Heater, page 5.

MAINTENANCE

WARNINGS

Never service heater while it is plugged in, con- nected to propane supply, operating, or hot. Se- vere burns and electrical shock can occur.

Keep heater clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

Do not block the flow of combustion or ventila- tion air.

1.Keep heater clean. Clean heater annually or as needed to re- move dust and debris. If heater is dirty or dusty, clean heater with a damp cloth. Use household cleaners on difficult spots.

2.Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once.

3.Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace.

4.Have heater inspected yearly by a qualified service agency.

5.Keep inside of heater free from combustible and foreign ob- jects. Remove motor and other internal parts if needed to clean inside of heater (see Service Procedures, page 8).

6.Clean fan blades each season or as needed (see Fan, page 8).

For morevisit www..com

105331-01C

Image 6
Contents Table of Contents Propane Construction TM HeaterSafety Information Product Identification UnpackingPropane Supply Assembly InstallationTheory of Operation Ventilation Operation To Start HeaterTo Stop Heater MaintenanceStorage To Restart HeaterTroubleshooting Observed Fault Possible Cause RemedyMotor Service ProceduresElectrical System FANIgnitor Removing Ignitor Mounting Screw and IgnitorIllustrated Parts Breakdown Models BLP50VA, REM50PVA RLP50VA, RM50PVAParts List KEY Part Description QTYAccessories SpecificationsReplacement Parts Technical ServiceOwners Registration Form Postage Required PROPANE/LP Forced AIR Heaters PROPANE/LP Convection Heaters GAS ChimeneasWarranty and Repair Service

ROPANE CONSTRUCTION HEATER specifications

Desa Ropane Construction Heater is a powerful solution designed to provide efficient heating for construction sites, workshops, and other commercial environments. With its robust build and advanced technology, it ensures consistent warmth even in the coldest weather conditions.

One of the main features of the Desa Ropane Construction Heater is its high heat output. With various models available, users can choose units that deliver up to 200,000 BTUs, making it suitable for large spaces. This high output ensures that materials set properly and that workers remain comfortable and productive, regardless of the chilly outdoor conditions.

Another notable characteristic is its portability. The heater is designed with rugged wheels and a durable casing, allowing it to be easily maneuvered from one location to another. This feature is especially beneficial for construction sites where the heating needs may change throughout the day or the project.

The heater operates on propane, leveraging the fuel's high efficiency for longer heating durations. Its ability to quickly warm up spaces ensures that downtime is minimized, which is crucial in the fast-paced world of construction. Additionally, propane is readily available and cost-effective, making this heater an economical choice for contractors.

Desa Ropane Construction Heater also features an adjustable heat control system, allowing users to set the desired temperature according to their specific needs. This flexibility is key to optimizing energy consumption and ensuring safety, as it prevents overheating in smaller spaces.

Safety is a top priority in any heating system, and the Desa Ropane heater incorporates several built-in safety features. These include automatic shut-off mechanisms that activate in case of low oxygen levels or if the unit overheats. This provides peace of mind for users while maintaining a safe working environment.

The design of the heater also includes a directional venting system, which allows for more effective heat distribution. This system ensures that areas are warmed evenly, reducing cold spots that can lead to discomfort or inefficiencies.

In summary, the Desa Ropane Construction Heater stands out with its exceptional heat output, portability, adjustable controls, and safety features. This heater is built to cater to the specific requirements of construction and commercial spaces, providing reliable, efficient heating solutions that enhance productivity and comfort. Its combination of technology and practicality makes it a preferred choice for construction professionals across various industries.