Desa VFN24R, VFN30R, VFN18R installation manual Unvented VENT-FREE Natural GAS LOG Heater

Page 1

UNVENTED (VENT-FREE)

NATURAL GAS LOG HEATER

VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIED AS

VENTED DECORATIVE APPLIANCES

OWNER’S OPERATION AND INSTALLATION MANUAL

VFN18R

VFN24R

VFN30R

18", 24", and 30"

Remote-Ready

 

OTO

OL

F

N

I H

O

 

EMBER MASTER

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

Installation and service must be per- formed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, adjust- ment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installa- tion and operational procedures. For as- sistance or additional information con- sult a qualified installer, service agency, or the gas supplier.

WARNING: This appliance is for installa- tion only in a solid-fuel burning masonry or UL127 factory-built fireplace, or in an approved ventless firebox. It is design- certified for these installations in accor- dance with ANS Z21.11.2. Exceptions: Do not install this appliance in a factory-built fireplace that includes instructions stat- ing it has not been tested or should not be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 4 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufac- tured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference

Image 1
Contents What to do if YOU Smell GAS Unvented VENT-FREE Natural GAS LOG HeaterFireplace Manufacturers INC Unvented Natural GAS LOG Heater Safety InformationProduct Identification Local Codes Product FeaturesUnpacking Providing Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsCheck GAS Type InstallationMinimum Noncombustible Material Clearances If Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesGas supply. Follow all local codes Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Installing Front Log #1 Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS to Appliance Manual Lighting ProcedureOptional Remote Operation Pilot Flame Pattern Inspecting BurnersCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceFront Burner Flame Pattern LogsObserved Problem Possible Cause Remedy TroubleshootingSee Wiring Diagram, Gas leak. See Warning statement Wiring Diagram SpecificationsReplacement Parts Service HintsVFN18R VFN24R VFN30R Illustrated Parts BreakdownKEY Part Numbers VFN18R VFN24R VFN30R Description QTY Parts ListAccessories 105072 Warranty Information

VFN24R, VFN18R, VFN30R specifications

Desa VFN18R, VFN24R, and VFN30R are a series of innovative heating solutions designed to meet varying heating needs while offering efficiency and reliability. Each model in the VFN range has unique features tailored to residential and commercial applications, contributing to versatile heating solutions.

One of the main characteristics of the VFN series is their impressive heating capacities. The VFN18R model is designed to deliver up to 18,000 BTU/hour, making it suitable for medium-sized spaces. The VFN24R, with its 24,000 BTU/hour output, is ideal for larger areas where more substantial heating is required. Finally, the VFN30R boasts an output of 30,000 BTU/hour, making it a powerful option for substantial heating demands, whether in warehouses, workshops, or expansive living spaces.

These models incorporate advanced technologies to maximize efficiency and performance. Each unit features a high-efficiency heat exchanger designed to produce a more significant amount of heat with lower fuel consumption. This not only translates into cost savings for the user but also reduces environmental impact by minimizing emissions.

In addition, the VFN series is built with a user-friendly interface, making operation straightforward. The units often include programmable thermostats, allowing users to set desired temperatures and schedules, optimizing energy consumption based on specific heating needs. Some models also come with remote control capabilities, offering added convenience.

Safety is a top priority for the VFN models. They come equipped with safety features such as an automatic shut-off system, which activates in case of overheating or malfunction. This contributes to peace of mind, especially in environments with high activity levels or sensitive materials.

The design of the VFN series also enhances their usability and adaptability. These units are compact and can be easily mounted on walls or placed in corners without taking up excessive space. Their aesthetic design allows them to blend seamlessly into different settings, from modern homes to traditional establishments.

In summary, the Desa VFN18R, VFN24R, and VFN30R are versatile heating solutions combining efficiency, safety, and ease of use. With varied heating capacities tailored for different needs and advanced technologies that enhance performance, these models stand out as reliable options for anyone seeking effective heating solutions. Whether for residential comfort or commercial utility, the VFN series delivers on multiple fronts.