Desa VFN30R, VFN24R, VFN18R Checking GAS Connections, Pressure Testing gas Supply Piping system

Page 12

FIREPLACE MANUFACTURERS INC.

UNVENTED NATURAL GAS LOG HEATER

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing gas Supply Piping system

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 14).

2.Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 15). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Open

Equipment

ShutoffClosed

Valve

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Fig- ure 14).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to gas control (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 14 through 16). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 15).

1.Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was con- nected.

3.Pressurize supply piping system by either using compressed air or open- ing main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

Figure 14 - Equipment Shutoff Valve

Equipment Shutoff Valve

Gas Control

Location

 

Gas Meter

Figure 15 - Checking Gas Joints

12

105072

Image 12
Contents Unvented VENT-FREE Natural GAS LOG Heater What to do if YOU Smell GASSafety Information Fireplace Manufacturers INC Unvented Natural GAS LOG HeaterProduct Features Product Identification Local CodesUnpacking AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Check GAS TypeIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Area of Various Standard Round FluesConnecting to GAS Supply Gas supply. Follow all local codesPressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs Installing Front Log #1For Your Safety Read Before Lighting Operating HeaterLighting Instructions Manual Lighting Procedure To Turn OFF GAS to ApplianceOptional Remote Operation Inspecting Burners Pilot Flame PatternCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleFront Burner Flame Pattern LogsTroubleshooting Observed Problem Possible Cause RemedySee Wiring Diagram, Gas leak. See Warning statement Specifications Wiring DiagramReplacement Parts Service HintsIllustrated Parts Breakdown VFN18R VFN24R VFN30RParts List KEY Part Numbers VFN18R VFN24R VFN30R Description QTYAccessories 105072 Warranty Information

VFN24R, VFN18R, VFN30R specifications

Desa VFN18R, VFN24R, and VFN30R are a series of innovative heating solutions designed to meet varying heating needs while offering efficiency and reliability. Each model in the VFN range has unique features tailored to residential and commercial applications, contributing to versatile heating solutions.

One of the main characteristics of the VFN series is their impressive heating capacities. The VFN18R model is designed to deliver up to 18,000 BTU/hour, making it suitable for medium-sized spaces. The VFN24R, with its 24,000 BTU/hour output, is ideal for larger areas where more substantial heating is required. Finally, the VFN30R boasts an output of 30,000 BTU/hour, making it a powerful option for substantial heating demands, whether in warehouses, workshops, or expansive living spaces.

These models incorporate advanced technologies to maximize efficiency and performance. Each unit features a high-efficiency heat exchanger designed to produce a more significant amount of heat with lower fuel consumption. This not only translates into cost savings for the user but also reduces environmental impact by minimizing emissions.

In addition, the VFN series is built with a user-friendly interface, making operation straightforward. The units often include programmable thermostats, allowing users to set desired temperatures and schedules, optimizing energy consumption based on specific heating needs. Some models also come with remote control capabilities, offering added convenience.

Safety is a top priority for the VFN models. They come equipped with safety features such as an automatic shut-off system, which activates in case of overheating or malfunction. This contributes to peace of mind, especially in environments with high activity levels or sensitive materials.

The design of the VFN series also enhances their usability and adaptability. These units are compact and can be easily mounted on walls or placed in corners without taking up excessive space. Their aesthetic design allows them to blend seamlessly into different settings, from modern homes to traditional establishments.

In summary, the Desa VFN18R, VFN24R, and VFN30R are versatile heating solutions combining efficiency, safety, and ease of use. With varied heating capacities tailored for different needs and advanced technologies that enhance performance, these models stand out as reliable options for anyone seeking effective heating solutions. Whether for residential comfort or commercial utility, the VFN series delivers on multiple fronts.