Desa VF-24P-BTB, VF-24P-PDG, VF-24N-PDG Troubleshooting, Observed Problem Possible Cause Remedy

Page 19

TROUBLESHOOTING

19

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off and un- plug heater and let cool before servicing.Only a qualified service person should service and repair

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.This can damage ODS/

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to ignitor

1.

Reconnect ignitor cable

spark at ODS/pilot

 

cable

 

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

base panel.

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

6.

Ignitor electrode positioned wrong or

6.

Replace pilot assembly for remote-ready

 

 

broken

 

units; Replace ignitor electrode for vari-

 

 

 

 

able manually controlled units

 

 

 

 

 

 

When ignitor button is pressed, there is spark

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

removed

 

5.

Depleted gas supply (propane/LP

5.

Contact local propane/LP gas company

 

 

only)

6.

Clean ODS/pilot (see Cleaning and

 

6.

ODS/pilot is clogged

 

Maintenance, page 18) or replace

 

 

 

 

ODS/pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

ODS/pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Safety interlock system has been triggered

4.Equipment shutoff valve not fully open

5.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged ODS/ pilot

6.Thermocouple connection loose at con- trol valve

1.Press in control knob fully

2.After ODS/pilot lights, keep control knob pressed in 30 seconds

3.Wait one minute for safety interlock sys- tem to reset. Repeat ignition operation

4.Fully open equipment shutoff valve

5.A) Contact local natural or propane/LP gas company

B) Clean ODS/pilot (see Cleaning and Maintenance, page 18) or replace ODS/ pilot assembly

6.Hand tighten until snug, then tighten 1/4 turn more

7.Replace pilot assembly

8.Replace control valve

For more information, visit www.desatech.com

111826-01

Image 19
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsRemote Ready Models Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features Local CodesConfined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation and Clearances for VENT-FREE Operation InstallationCheck GAS Type Minimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesArea of Various Standard Round Flues Installing Damper Clamp Accessory for Vented OperationInstalling Heater Assembly Installation Items NeededConnecting to GAS Supply Pressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Checking Gas Joints propane/LP only Operating Heater For Your Safety Read Before LightingLighting Instructions Remote Control Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Ghrcta Series Operation Thermostat Control OperationPilot Flame Pattern Inspecting BurnersBurner Flame Pattern Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Observed Problem Possible Cause VF-18N-PDG/VF-18N-BTB SpecificationsReplacement Parts Wiring DiagramService Hints Technical ServiceThis page Intentionally Left Blank Illustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListAccessories Owners Registration Form Postage Required 111826-01 Warranty Information