TECHNICAL

 

You may have further questions about installation, operation, or troubleshooting.

 

 

 

 

 

 

SERVICE

 

If so, contact DESA International’s Technical Service Department at

 

 

1-800-DESA LOG (1-800-337-2564).

 

 

 

 

 

SPECIFICATIONS

 

 

Standard

Standard

Premium

 

 

 

 

Oak

Oak

Oak and Birch

 

 

 

 

18" Variable

24" Variable

24" Variable

 

 

 

 

Manually-

Manually-

Manually-

 

 

 

 

Controlled

Controlled

Controlled

 

 

 

Btu (Variable)

16,000/27,000

16,000/31,500

20,000/39,000

 

 

 

 

 

Type Gas

Propane Only

Propane Only

Propane Only

 

 

 

Ignition

Piezo

Piezo

Piezo

 

 

 

Pressure Manifold

8.0" W.C.

8.0" W.C.

8.0" W.C.

 

 

 

Inlet Gas

 

 

 

 

 

 

 

 

Pressure (in. of water)

 

 

 

 

 

 

 

 

Maximum

14"

14"

14"

 

 

 

 

 

Minimum*

11"

11"

11"

 

 

 

 

 

* For input adjustment

 

 

 

 

 

 

 

 

Shipping Weight

27 lbs.

29 lbs.

30 lbs.

 

SERVICE

 

When gas pressure is too low

 

 

 

 

 

 

• pilot will not stay lit

 

 

 

 

 

HINTS

 

 

 

 

 

 

 

• burners will have delayed ignition

 

 

 

 

 

 

 

• heater will not produce specified heat

 

 

 

 

 

 

 

• propane/LP gas supply may be low

 

 

 

 

 

 

 

When gas quality is bad

 

 

 

 

 

 

 

• pilot will not stay lit

 

 

 

 

 

 

 

• burners will produce flames and soot

 

 

 

 

 

 

 

• heater will backfire when lit

 

 

 

 

 

 

 

You may feel your gas pressure is too low or gas quality is bad. If so, contact your

 

REPLACEMENT

 

local propane/LP gas supplier.

 

 

 

 

 

 

Note: Use only original replacement parts. This will protect your warranty cover-

 

 

 

 

PARTS

 

age for parts replaced under warranty.

 

 

 

 

 

 

Parts Under Warranty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact authorized dealers of this product. If they can’t supply original replace-

 

 

 

ment part(s), call DESA International’s Technical Service Department at

 

 

 

1-800-323-5190. When calling DESA International, have ready

 

 

 

• your name and address

 

 

 

 

 

 

 

• model number of your heater

 

 

 

 

 

 

 

• how heater was malfunctioning

 

 

 

 

 

 

 

• type of gas used (propane or natural gas)

 

 

 

 

 

 

• purchase date

 

 

 

 

 

 

 

 

Usually, we will ask you to return the defective part to the factory.

 

 

 

Parts Not Under Warranty

 

 

 

 

 

 

 

Contact authorized dealers of this product. If they can’t supply original replace-

 

 

 

ment part(s), call DESA International’s Parts Department at 1-800-972-7879 for

 

 

 

referral information. When calling DESA International, have ready

 

 

 

• model number of your heater

 

 

 

 

 

 

 

• the replacement part number

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

103310

Image 29
Contents FLAME-MAX OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Log DesignContents Safety Information With this heater Product Identification Local Codes FeaturesUnpacking ProductProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR forDetermining AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallingMinimum Wall and Ceiling Clearances see Figure Minimum Fireplace Clearance To Combustible MaterialsLOG Sizing Requirements Minimum Non Combustible Material Clearances If Using Mantel Installing Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed InstallingInstallation Items Needed Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing Gas Supply Piping SystemManual Shutoff Valve Pressure Testing Heater Gas ConnectionsFor Standard Oak Model Installing LogsFor Premium Models Installing Premium One-Piece Log SetOperating Heater For Your Safety Read Before LightingVariable Control Operation Pilot Flame Pattern Operating Heater Inspecting BurnersQualified service person should service and repair heater Trouble ShootingODS/PILOT and Burner LogsTROUBLE- Shooting Maintenance,Refer to Air for Com Gas leak. See Warning Replacement ServiceTechnical HintsIllustrated Parts Breakdown KEY Part Number for VYS18P VYS24P Description QTY Parts ListBirch Log Models VYD24P and VYBD24P KEY Part Number for VYD24P VYBD24P Description QTY Valve GA5010 AccessoriesHood GA6050 Hood GA6052103310 Keep this Warranty Warranty Information