Desa KEROSENE HIGH PRESSURE PORTABLE FORCED AIR HEATERS Preventative Maintenance Schedule

Page 6

OPERATION WITH PORTABLE GENERATOR

WARNING: Before operating heater or any appliance from a portable generator, verify that generatorhasbeenproperlycon- nectedtoearthground.Improper grounding or failure to ground generator can result in electro- cution if a ground fault occurs. Refertoowner’smanualsupplied by generator manufacturer for proper grounding procedures.

The operating voltage range of the heater is 108 to 132 Volts (120 Volts +/- 10%). Prior to plugging heater into generator the output voltage should be verified (if generator is equipped with the au- tomatic idle feature, the output voltage should be measured with the generator running at full speed).

If the voltage does not measure in this range the

heater should not be plugged into the generator.

Refer to Operation, page 4, for starting, stopping

and resetting heater procedures.

 

Alternator

Copper

or Brass

 

 

Grounding

 

Point

Ground

Ground Wire

Lug

(#10 AWG -

 

 

Stranded-Copper)

Figure 5 - Typical Generator Grounding Method (Generator construction may vary from that shown)

PREVENTATIVE MAINTENANCE SCHEDULE

WARNING: Never service heater while it is plugged in, operating

or hot. Severe burns and electrical shock can occur.

Item

How Often

How To

Fuel tank

Flushevery150-200hoursofoperation

See Storing,

 

or as needed

, page 5

Filler neck screen

Check for particles in fuel when filling

Lift out of fuel tank and rinse with

 

fuel tank. Clean when dirty

clean kerosene

Fuel filter assembly (Fuel

Clean twice a heating season or replace

See Fuel Filters, page 12

tank)

as needed

 

Fuel filter lines

Check and tighten loose connections

See Fuel Lines, Page 12

 

occasionally

 

Fuel filter (In pump or ex-

Clean fuel filter element every 250

See Fuel Filters, page 12

ternal canister)

hours

 

Spark plug

Clean and regap every 300 hours of

See Spark Plug, page 10

 

operation or replace as needed

 

Fan blades and air

Clean each season or as needed

See Fan Blades and Air Deflec-

deflectors

 

tors, page 10

Air passages around burner

Check each season for dirt and

Remove debris and trash with a

head

debris

clean, soft cloth

Motor

Not required, permanently lubricated

 

6

www.desatech.com

110098-01F

Image 6
Contents Table of Contents Fueling Safety InformationFollow all local ordinances and codes when using heater Top 4 FtProduct Identification UnpackingOperation Ventilation Follow all ventilation and safety informationFuels To Start HeaterTo Restart Heater STORING, Transporting of ShippingTo Stop Heater Unplug extension cord from outletPreventative Maintenance Schedule Troubleshooting Observed Problem Possible Cause RemedyDamaged electronic ignitor Tank Wrong pump pressure Adjust pump pressure see Can be seenFill with clean fuel Wrong fuel Remove fuel see StoringFAN Blades and AIR Deflectors Service ProceduresUpper Shell Removal Spark PlugRemove pressure gauge plug from fuel pump port marked Gauge GaugeFuel Lines Remove upper shell see Upper Shell Re- moval,Fuel Filters Illustrated Parts Breakdown Models B350D, SB350D and R350AParts List NTC-4CModels B600D, SB600D and R600A NTC-4C Burner Head Assembly 350,000 and 600,000 BTU/HR Illustrated Parts Breakdown and Part ListNPF-5C Motor and Pump Assembly 350,000 and 600,000 BTU/HR Part ListSpecifications Wiring DiagramOutput Rating Btu/Hr 350,000 600,000 Fuel Accessory Maintenance KitsTechnical Service Replacement Parts110098-01F Warranty and Repair Services Limited Warranty

KEROSENE HIGH PRESSURE PORTABLE FORCED AIR HEATERS specifications

Desa Kerosene High Pressure Portable Forced Air Heaters are engineered to deliver efficient and effective heating solutions for a variety of applications. These heaters stand out for their portability, high heating capacity, and adaptability to different environments, making them ideal for construction sites, warehouses, livestock facilities, and other outdoor settings.

One of the standout features of Desa heaters is their high-pressure design. This technology allows for rapid heating by forcing hot air into the surrounding area at a higher velocity compared to traditional heaters. This means that larger spaces can be heated more quickly and efficiently. With adjustable outlets, users can direct heat where it is needed most, further optimizing energy use and comfort.

These heaters utilize high-quality kerosene fuel, which offers a robust heating output while maintaining a clean burn. Kerosene is widely available and often more cost-effective than other heating fuels. The heaters are designed to efficiently burn kerosene, ensuring minimal emissions and environmental impact. This makes them suitable for both indoor and outdoor use when proper ventilation is provided.

Safety is a primary focus in the design of Desa high-pressure heaters. They are equipped with multiple safety features, including automatic shut-off mechanisms, which activate in the event of overheating or abnormal operation conditions. Additionally, robust construction ensures durability, allowing these heaters to withstand tough working conditions while providing reliable performance over time.

Ease of operation is another key characteristic of Desa heaters. Many models come with user-friendly controls that allow for straightforward adjustments of temperature settings and fan speeds. Portability is enhanced through built-in handles and lightweight designs, allowing users to transport the heaters with ease.

In conclusion, Desa Kerosene High Pressure Portable Forced Air Heaters offer effective heating solutions that combine high performance, safety, and convenience. With their advanced features, durability, and efficiency, they stand as a reliable choice for anyone needing substantial heat output in challenging environments. Whether for commercial, industrial, or agricultural use, these heaters provide an essential service by delivering warmth whenever and wherever it is most required.