Desa REM50C, B50H Storing, Preventative Maintenance Schedule, TRANSPORTING, or Shipping

Page 6

STORING,

TRANSPORTING, OR SHIPPING

PREVENTATIVE MAINTENANCE SCHEDULE

6

Note: If shipping, transport companies require fuel tanks to be empty.

1.Drain fuel tank. Drain fuel through fuel cap opening. Be sure all fuel is re- moved.

2.If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir, and drain again. This will prevent excess debris from clogging filters during future use.

3.Replace fuel cap. Properly dispose of old and dirty fuel. Check with local automotive service stations that recycle oil.

4.If storing, store heater in dry place. Make sure storage place is free of dust and corrosive fumes.

IMPORTANT: Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater.

WARNING

Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

Item

How Often

How To

Fuel tank

Flush every 150-200 hours

See Storing, Transporting, or

 

of operation or as needed.

Shipping, above.

Air output and

Replace every 500 hours of

See Air Output, Air Intake,

lint filters

operation or once a year.

and Lint Filters, page 8.

Air intake

Wash and dry with soap and

See Air Output, Air Intake,

filter

water every 500 hours of op-

and Lint Filters, page 8.

 

eration or replace as needed.

 

Fuel filter

Clean twice a heating season

See Fuel Filter, page 9.

 

or replace as needed.

 

Ignitor

No maintenance required.

 

Fan blades

Clean each season or as needed.

See Fan, page 8.

Motor

Not required/permanently lubricated

102553

Image 6
Contents Portable Forced AIR Heater Contents Safety Information Unpacking Theory Operation 50,000 Btu/Hr ModelTo Stop Heater Fuels Ventilation OperationTo Start Heater To Restart HeaterPreventative Maintenance Schedule StoringTRANSPORTING, or Shipping TROUBLE- Shooting Possible CauseFan Service ProceduresUpper Shell Removal Air Output, Air Intake, and Lint FiltersPump Pressure Adjustment Fuel FilterNozzle Pump RotorSpecifications Wiring Diagram Gap Adjusting Screw LocationsTechnical Service Replacement PartsAccessories Illustrated Parts Breakdown Parts List Models B50H and REM50CWarranty and Repair Service International

B50H, REM50C specifications

Desa B50H and REM50C are innovative solutions designed for advanced energy management and efficient operation in various applications. Both models embody a blend of cutting-edge technology and user-centric design, making them ideal for modern energy needs.

The Desa B50H, known for its robust performance, offers a high capacity and efficient energy output. This model is equipped with a powerful engine that ensures reliable operation while keeping fuel consumption at bay. The B50H features advanced thermal management systems that optimize engine temperature, thus extending the lifespan of the unit. Its user-friendly interface allows operators to monitor performance metrics seamlessly, ensuring effortless management of energy resources.

One of the key characteristics of the Desa B50H is its adaptability to different environmental conditions. Whether used in urban settings or remote locations, this model delivers stable performance, highlighting its versatility. Additionally, it incorporates noise reduction technologies, making it suitable for use in residential areas without disturbing the peace. The design prioritizes sustainability, integrating features that minimize emissions and promote eco-friendly usage.

On the other hand, the REM50C stands out with its exceptional connectivity options and smart technology integration. It is built with a focus on smart grid compatibility, allowing seamless communication with other energy systems. This capability enhances its efficiency, enabling real-time data exchange about energy consumption and demand. The REM50C also supports remote monitoring and control applications, allowing users to manage energy use from anywhere.

The REM50C incorporates advanced safety features, including overload protection and automated shutdown mechanisms, ensuring safe operation under various load conditions. Its compact design makes it easy to install, even in space-constrained environments. The model is engineered for durability, constructed with high-quality materials that withstand harsh conditions without compromising performance.

In summary, both the Desa B50H and REM50C represent significant advancements in energy management technology. The B50H is characterized by its robust performance and fuel efficiency, while the REM50C excels in smart technology integration and connectivity. Together, they offer versatile solutions suitable for a range of applications, from residential to industrial, catering to the evolving demands of energy management in today's world.