Desa RFN30T installation manual OWNER’S Operation and Installation Manual

Page 1

VENT-FREE NATURAL GAS

RADIANT FLAME® HEATER

OWNER’S OPERATION AND INSTALLATION MANUAL

RFN30T

15,000 to 30,000 Btu/ Hr with Thermostat

Shown with

Optional Mantel featuring Built-in Base

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, per- sonal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installa- tion, adjustment, alteration, ser- vice, or maintenance can cause injury or property damage. Re- fer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion must be provided. Refer to Air For Combustion and Ventilation section on page 5 of this manual.

This appliance may be installed in an aftermarket*, permanently located, manufac- tured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual15,000 to 30,000 Btu/ Hr with Thermostat 15,000 to 30,000 BTU/HR VENT-FREE Natural GAS Heater Safety InformationSafety Pilot Product FeaturesProduct Identification Local Codes UnpackingInstalling Log AssemblyAssembling Heater Removing Front Panel Of HeaterProviding Adequate Ventilation AIR for Combustion and VentilationAssembling and Attaching Brass Trim Unusually Tight ConstructionDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Mounting Heater on Optional Hearth Base Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Placing Heater On Mounting BracketMounting Heater to Optional Hearth Base Securing Hearth Base to FloorSee Instructions Included With Mantel Kit Assembling Mantel Gas Connection Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceInspecting Burner Manual Lighting ProcedureThermostat Control Operation Pilot Flame PatternReplacement Parts Cleaning and MaintenanceService Hints Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Observed Problem Possible Cause Technical Service SpecificationsParts Centrals Accessories RFN30T Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListWarranty Information

RFN30T specifications

The Desa RFN30T is a state-of-the-art heating appliance designed to meet the demands of modern living while ensuring energy efficiency and user convenience. This product showcases the latest advancements in heating technology, making it a popular choice among homeowners seeking reliable warmth during the colder months.

One of the standout features of the Desa RFN30T is its powerful heating capacity. It is equipped with a robust heating element that delivers rapid warmth, effectively heating spaces up to 1,000 square feet. This makes it ideal for both residential and commercial applications, ensuring comfort in larger areas without compromising on performance.

Energy efficiency is a critical aspect of the Desa RFN30T. The appliance utilizes advanced thermal regulation technology that allows for precise temperature control. This feature helps in reducing energy consumption, making it both an eco-friendly choice and a cost-effective solution for home heating. The intelligent thermostat automatically adjusts the heating output based on the room temperature, which further enhances energy savings.

The design of the Desa RFN30T combines functionality with aesthetic appeal. Its sleek and modern look allows it to blend seamlessly into various interior styles. The unit is also lightweight and portable, allowing users to move it from room to room effortlessly. Its compact size does not compromise its heating capabilities, making it suitable for small spaces like apartments, offices, or even workshops.

Safety is a top priority with the Desa RFN30T. The appliance comes equipped with several safety features, including an automatic shutoff mechanism that activates in case of overheating or accidental tipping. This ensures that users can operate the heater with peace of mind, knowing that it meets rigorous safety standards.

Moreover, the Desa RFN30T is designed for ease of use. It features a user-friendly control panel with intuitive settings, making it accessible for individuals of all ages. With its simple installation process, users can quickly set up the heater and enjoy warmth within minutes.

In summary, the Desa RFN30T is a reliable and efficient heating solution that excels in performance, safety, and user convenience. With its powerful heating capacity, energy-saving technologies, stylish design, and safety features, the RFN30T stands out as an excellent choice for anyone in need of effective heating solutions.