Desa RFN30T installation manual Observed Problem Possible Cause

Page 19

OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, etc. (see IMPORTANT

 

 

statement above)

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Ventilate room. Stop using odor caus- ing products while heater is running

2.Locate and correct all leaks (see Check- ing Gas Connections, page 13)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 16)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 13)

 

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 13)

Moisture/condensation noticed on windows

1. Not enough combustion/ventilation air

1. Refer to Air for Combustion and Venti-

 

 

lation requirements (page 5)

www.desatech.com

104433

19

Image 19
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual15,000 to 30,000 Btu/ Hr with Thermostat 15,000 to 30,000 BTU/HR VENT-FREE Natural GAS Heater Safety InformationLocal Codes Unpacking Product FeaturesSafety Pilot Product IdentificationRemoving Front Panel Of Heater AssemblyInstalling Log Assembling HeaterUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Assembling and Attaching Brass TrimDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Locating Heater InstallationInstallation Items Check GAS TypeThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Placing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Heater on Optional Hearth Base Attaching Mounting Bracket To WallMounting Heater to Optional Hearth Base Securing Hearth Base to FloorSee Instructions Included With Mantel Kit Assembling Mantel Gas Connection Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Heater Lighting InstructionsPilot Flame Pattern Manual Lighting ProcedureInspecting Burner Thermostat Control OperationReplacement Parts Cleaning and MaintenanceService Hints Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Observed Problem Possible Cause Technical Service SpecificationsParts Centrals Accessories RFN30T Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListWarranty Information

RFN30T specifications

The Desa RFN30T is a state-of-the-art heating appliance designed to meet the demands of modern living while ensuring energy efficiency and user convenience. This product showcases the latest advancements in heating technology, making it a popular choice among homeowners seeking reliable warmth during the colder months.

One of the standout features of the Desa RFN30T is its powerful heating capacity. It is equipped with a robust heating element that delivers rapid warmth, effectively heating spaces up to 1,000 square feet. This makes it ideal for both residential and commercial applications, ensuring comfort in larger areas without compromising on performance.

Energy efficiency is a critical aspect of the Desa RFN30T. The appliance utilizes advanced thermal regulation technology that allows for precise temperature control. This feature helps in reducing energy consumption, making it both an eco-friendly choice and a cost-effective solution for home heating. The intelligent thermostat automatically adjusts the heating output based on the room temperature, which further enhances energy savings.

The design of the Desa RFN30T combines functionality with aesthetic appeal. Its sleek and modern look allows it to blend seamlessly into various interior styles. The unit is also lightweight and portable, allowing users to move it from room to room effortlessly. Its compact size does not compromise its heating capabilities, making it suitable for small spaces like apartments, offices, or even workshops.

Safety is a top priority with the Desa RFN30T. The appliance comes equipped with several safety features, including an automatic shutoff mechanism that activates in case of overheating or accidental tipping. This ensures that users can operate the heater with peace of mind, knowing that it meets rigorous safety standards.

Moreover, the Desa RFN30T is designed for ease of use. It features a user-friendly control panel with intuitive settings, making it accessible for individuals of all ages. With its simple installation process, users can quickly set up the heater and enjoy warmth within minutes.

In summary, the Desa RFN30T is a reliable and efficient heating solution that excels in performance, safety, and user convenience. With its powerful heating capacity, energy-saving technologies, stylish design, and safety features, the RFN30T stands out as an excellent choice for anyone in need of effective heating solutions.