Desa REM30LP owner manual Assembly, Propane Supply, Installation

Page 4

4

ASSEMBLY PROPANE SUPPLY INSTALLATION

ASSEMBLY

1.Remove screw from top of fan guard. Discard screw.

2.Insert nut clip (provided with handle) with flat side facing up through slot in top of shell. Align holes in nut clip with screw hole behind slot in top of shell. (see Figure 4).

3.Place handle over hole and clip. Insert two screws (provided with handle) through handle and tighten into shell. Make sure rear screw goes through shell and into fan guard. Tighten screws firmly.

Remove

Screw

Figure 3 - Removing Screw from Top of Fan Guard

Flat Side Facing Up

Nut Clip

Shell

Slot

Figure 4 - Installing Nut Clip

Screws

Handle

Nut Clip

Rear of

Heater

Figure 5 - Attaching Handle

PROPANE SUPPLY

Propane gas and propane tank(s) are to be furnished by the user.

Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA B149.2. Your local library or fire department will have this booklet.

The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount:

1.The amount of propane gas in tank(s)

2.The temperature of tank(s)

This heater is designed to operate with a minimum 20-pound propane tank. You may need two or more tanks or one larger tank in colder weather. Use a 100-pound tank for longer operation or in very cold weather. Less gas is vaporized at lower temperatures. Your local propane gas dealer will help you select the proper supply system. The minimum surrounding air temperature rating for each heater is -20°F (-29°C).

Average Temp (°F)

No. Of Tanks

At Tank Location

(100-pound)

40°

1

32°

1

20°

1

10°

1

1

-10°

2

-20°

2

INSTALLATION

WARNING: Review and understand the warnings in the Safety Information section, page 2. They are needed to safely operate this heater. Follow all local codes when using this heater.

WARNING: Test all gas piping and connections for leaks after installation or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

1.Provide propane supply system (see Propane Supply).

2.Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL fitting counterclockwise into threads on tank. Tighten firmly using wrench. IMPORTANT: Position regula- tor so that hose leaving the regulator is in a horizontal position (see Figure 6, page 5). This places the regulator vent in the proper position to protect it from the weather.

For morevisit www..com

104163-01H

Image 4
Contents Table of Contents BLP30 REM30LPSafety Information Unpacking Product IdentificationFundamentals Operation Installation AssemblyPropane Supply Ventilation To Start HeaterMaintenance SpecificationsStorage To Stop HeaterTroubleshooting Observed Fault Possible Cause RemedyService Procedures Electrical SystemMotor FANRemoving Ignitor Wire from Piezo Ignitor IgnitorIllustrated Parts Breakdown Models BLP30 and REM30LPParts List KEY Part Number Description QTYReplacement Parts AccessoriesTechnical Service Owners Registration Form Postage Required PROPANE/LP Forced AIR Heaters PROPANE/LP Convection Heaters GAS ChimeneasWarranty and Repair Service

REM30LP specifications

Desa REM30LP is a cutting-edge, energy-efficient heating solution designed for residential and commercial spaces. Characterized by its advanced technology, the REM30LP delivers optimal performance while ensuring a comfortable environment. This unit operates on LP (liquid propane) gas, making it a practical choice for homes and businesses seeking an effective heating alternative.

One of the main features of the Desa REM30LP is its impressive heating capacity. It can provide warmth for areas up to 1,000 square feet, making it suitable for large living rooms, workshops, or commercial settings. The unit utilizes a forced air heating system that rapidly circulates warm air, ensuring that every corner of the space is heated uniformly.

Another key characteristic of the REM30LP is its compact design. Unlike traditional heaters, which can be bulky and difficult to position, the REM30LP's sleek profile allows it to fit neatly in various locations without occupying significant floor space. This makes it an attractive option for users with limited room or those looking to maintain an uncluttered aesthetic.

The Desa REM30LP integrates several advanced technologies to enhance its performance and energy efficiency. One notable feature is its electronic ignition system, which eliminates the need for matches or lighter fluid. This not only improves safety but also ensures reliable starts every time the heater is activated. Additionally, the unit boasts safety features such as automatic shut-off systems and tip-over protection, providing peace of mind for homeowners.

Efficiency is further maximized by the heater's adjustable thermostat. Users can easily set their preferred temperature, and the REM30LP will automatically adjust its output to maintain consistent heating levels. This precision helps to save on energy costs while ensuring comfort.

In terms of installation, the Desa REM30LP offers versatility. It can be vented directly outdoors, allowing for a more flexible installation process in various spaces. This feature is particularly beneficial in homes where interior venting may not be feasible.

In conclusion, the Desa REM30LP is a compact, efficient, and effective heating solution that is perfect for a range of environments. With its advanced technologies, versatile installation options, and robust safety features, it stands out as a reliable choice for those in need of high-quality heating.