PROPANE/LP GAS HEATER

SPECIFICATIONS

 

VP10TA

Btu

10,000

Type Gas

Propane/LP Only

Ignition

Piezo

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Pressure Regulator Setting

8.5" W.C.

Inlet Gas Pressure (inches of water)

 

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

 

Heater

21 1/2 x 13 1/2 x 7

Carton

25 1/4 x 16 3/4 x 7 1/2

Weight (pounds)

 

Heater

14

Shipping

18

TECHNICAL SERVICE

SERVICEPUBLICATIONS

PARTS UNDER WARRANTY

Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call DESA International’s Technical Service De- partment at 1-800-323-5190 for information.

When contacting your dealer or DESA In- ternational, have ready:

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190.

You can also visit DESA International’s technical service web site at www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burner(s) will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

When Gas Quality Is Bad

pilot will not stay lit

burner(s) will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane/LP gas supplier.

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

ACCESSORY

Purchase this heater accessory from your local dealer. If they cannot supply this ac- cessory, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual.

EQUIPMENT SHUTOFF VALVE - GA5010

Equipment shutoff valve with 1/8" NPT tap.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they cannot supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready:

model number of your heater

the replacement part number

18

104083

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information PROPANE/LP GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installing Heater to Wall InstallationInstallation Items Check GAS TypePlacing Heater On Mounting Screws Installing Two Mounting ScrewsInstalling Bottom Mounting Screw Removing Front Panel Of HeaterConnecting to GAS Supply Heater and propane/LP supplyPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterThermostat Control Operation Manual Lighting ProcedureLighting Instructions To Turn OFF GAS To ApplianceCleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyBurner plaques do not light after ODS/pilot is lit Refer to Air for Combustion and Venti Illustrated Parts List VP10TA ODS/PILOTParts List VP10TATechnical Service Servicepublications SpecificationsReplacement Parts Service Hints104083 Warranty Information