Desa R 15 E UK Continued, Pump Pressure Adjustment, Fuel Filter, Spark Plug, Service Procedures

Page 8
Continued

®

R 15 E UK

PORTABLE FORCED AIR HEATER

SERVICE

PROCEDURES

Continued

PUMP PRESSURE

ADJUSTMENT

1.Remove pressure gauge plug from filter end cover.

2.Install accessory pressure gauge (part number HA1180).

3.Start heater (see Operation, page 5). Allow motor to reach full speed.

4.Adjust pressure. Turn relief valve to right to increase pressure. Turn relief valve to left to decrease pressure. See specifications below for correct pres- sure for each model.

5.Remove pressure gauge. Replace pres- sure gauge plug in filter end cover.

Pressure

Relief

Gauge

Valve

Plug

 

FUEL FILTER

1.Remove side cover screws using 5/16" nut-driver.

2.Remove side cover.

3.Pull rubber fuel line off fuel filter neck.

4.Carefully pry bushing and fuel filter out of fuel tank.

5.Wash fuel filter with clean fuel and re- place in tank.

6.Attach rubber fuel line to fuel filter neck.

7.Replace side cover.

Fuel Filter

Fuel

Line

Side Cover

Figure 10 - Fuel Filter Removal

SPARK PLUG

1.Remove upper shell, page 7.

2.Remove fan (see page 7).

3.Remove spark plug wire from spark plug.

4.Remove spark plug from burner head using 13/16" open-end wrench.

5.Clean and regap spark plug electrodes as follows: 1.9 mm (.075") gap

6.Install spark plug in burner head.

7.Attach spark plug wire to spark plug.

8.Replace fan (see page 7).

9.Replace fan guard and upper shell.

Burner

Spark Plug

Head

 

Wire

 

Spark

 

Plug

Figure 11 - Spark Plug Removal

Bend Here to Adjust Gap

Figure 8 - Pressure Gauge Plug Removal

 

Pump

 

Pressure
Model
(PSI/Bar)

50,000 Btu/Hr

4.9/0.338

1.9 mm (.075") Gap

Figure 12 - Spark Plug Gap

Pressure

Gauge

Figure 9 - Adjusting Pump Pressure

8

104975

Image 8
Contents PORTABLE FORCED AIR HEATER Heater Size 50,000 Btu/Hr Model R 15 E UKWARNINGS SAFETY INFORMATIONR 15 E UK PORTABLE FORCED AIR HEATER PRODUCT IDENTIFICATION UNPACKINGFUELS THEORY OF OPERATIONVENTILATION R 15 E UK PORTABLE FORCED AIR HEATERMAINTENANCE OPERATIONSTORING, TRANSPORTING, OR SHIPPING PREVENTATIVETROUBLESHOOTING See Pump Pressure Adjustment, pageSee Pump Pressure Adjustment, page R 15 E UK PORTABLE FORCED AIR HEATERAIR OUTPUT, AIR INTAKE, AND LINT FILTERS SERVICE PROCEDURESUPPER SHELL REMOVAL PUMP PRESSURE ADJUSTMENT ContinuedFUEL FILTER SPARK PLUGNOZZLE PUMP ROTORSERVICE PROCEDURES ContinuedILLUSTRATED PARTSBREAKDOWN R 15 E UKPARTS LIST R 15 E UKPART PARTSPECIFICATIONS WIRING DIAGRAMACCESSORIES AIR GAUGE KIT - HA1180EC CONFORMITY DECLARATION WARRANTY AND REPAIR SERVICE EQUIPMENT - LIMITED 1 YEAR WARRANTYWARRANTY SERVICE CERTIFICATE OF GENERAL