Desa FVF24N, and FVF30N, FVF18N installation manual Safety Information

Page 2

FIREPLACE MANUFACTURERS INCORPORATED

UNVENTED NATURAL GAS LOG HEATER

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.This heater shall not be installed in a bedroom or bathroom unless installed as a vented appliance (see Installing Damper Clamp Accessory page 10).

4.Never install the heater

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

5.Before installing in a solid fuel burn- ing fireplace, the chimney flue and fire- box must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.

6.If fireplace has glass doors, never op- erate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace open- ing has vents at the bottom, you must open the vents before operating heater.

7.You must operate this heater with a fire- place screen in place. Make sure fireplace screen is closed before running heater.

8.This log heater is designed to be smoke- less. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufactur- ing residues.

9.To prevent the creation of soot, follow the instructions in Cleaning and Main- tenance, page 20.

10.Do not allow fans to blow directly into the fireplace. Avoid any drafts that al- ter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

11.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

12.Do not use a blower insert, heat ex- changer insert or other accessory not approved for use with this heater.

13.This heater needs fresh, outside air ven- tilation to run properly. This heater has an oxygen depletion sensor (ODS) pi- lot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 4 through 6. If heater keeps shutting off, see Trouble- shooting, pages 17 through 19.

14.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

15.Do not use this heater to cook food or burn paper or other objects.

16.Never place any objects on the heater.

17.Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

18.Carefully supervise young children when they are in the room with heater.

19.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to in- spect the room heater and to replace any part of the control system and any gas control which has been under water.

20.Do not operate heater if any log is bro- ken. Do not operate heater if a log is chipped (dime-sized or larger).

21.Turn heater off and let cool before ser- vicing. Only a qualified service person should service and repair heater.

22.Operating heater above elevations of 4,500 feet could pilot outage.

2

105191

Image 2
Contents Patent Pending OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Safety Information Product Identification Local Codes Unpacking Product FeaturesSafety Pilot OperationUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsCheck GAS Type InstallationInstallation Minimum Wall and Ceiling Clearances see FigureMinimum Noncombustible Material Clearances If Using MantelIf Not Using Mantel Floor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceChimney Minimum Permanent Height ft Flue Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items Needed Attaching Flexible Gas Hose to Heater Gas RegulatorConnecting to GAS Supply Test gauge connection Sediment trap Tee joint Pipe wrenchChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Test Pressures In Excess Of 1/2 PsigInstalling Logs Installing Heat Majic One- Piece Log SetLighting Instructions For Your Safety Read Before LightingOperating Heater Inspecting Burners Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atTechnical Service Cleaning and MaintenanceService Hints Cleaning Burner Injector Holder and Pilot AIR Inlet HoleSpecifications Replacement PartsAccessories ODS Pilot Illustrated Parts BreakdownHeat Majic FVF18N FVF24N FVF30N Parts List KEY Part Number for FVF18N FVF24N FVF30N Description QTYWarranty Information