Installation Instructions
EXHAUST LENGTH CALCULATION
Table 1: RECOMMENDED MAXIMUM LENGTH
|
|
| ELECTRIC DRYERS |
| |
|
|
|
|
|
|
|
|
| Weather Hood Type |
| |
|
|
|
|
| |
| Recommended | Use only for short run installations | |||
|
|
|
|
|
|
|
| 4”(10.16cm) | 2 1/2”(6.35cm) | ||
No. of 90˚ | Rigid |
| Metallic Flexible* | Rigid | Metallic Flexible* |
elbows |
| ||||
|
|
|
|
| |
0 | 14m(46ft.) |
| 9m(30ft.) | 11m(37ft.) | 7m(24ft.) |
1 | 11m(38ft.) |
| 7.5m(25ft.) | 9m(30ft.) | 6m(20ft.) |
2 | 9m(31ft.) |
| 6m(20ft.) | 6.5m(22ft.) | 4m(14ft.) |
3 | 7m(24ft.) |
| 5m(16ft.) | 4.5m(15ft) | 3m(10ft.) |
* Do not use non metallic flexible duct.
EXHAUST DIRECTIONS
All dryers shipped from the factory are set up for rear exhausting. However exhausting can be on the right or left side of the cabinet or the bottom of the dryer.
• Remove access panel at back of dryer to gain access to internal ducts.
•Disconnect duct exhaust from blower housing.
•Remove desired knockout plate (either right or left side).
•Attach a 90° elbow duct to blower housing and facing desired opening.
•Reinstall rear access panel.
Same as other side
| Frontof dryer |
EXHAUST DUCT LOCATING DIMENSIONS
NOTE:
SPECIAL ACCESSORY
Stacking kit (Model no:SK-2A)
You can obtain the stacking kit from your retailer.
With this kit you can combine your dryer with a Samsung automatic washing machine to a washing and drying column. The appliances are stacked in a