Quadra-Fire FG21SP-LP owner manual Shock Risk Explosion Risk

Page 11

D. Gas Pressure

Proper input pressures are required for optimum appliance performance. Gas line sizing requirements need to be made following NFPA51.

WARNING

Fire Risk

Explosion Risk

High pressure will damage valve.

Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

WARNING

CHECK FOR GAS LEAKS

Fire Risk

Explosion Risk

Asphyxiation Risk

Check all fittings and connections.

Do not use open flame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially available, non-corrosive leak check solution. Be sure to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

WARNING

Fire Risk

Explosion Risk

Do NOT change the valve settings.

This valve has been preset at the factory.

Changing valve settings may result in fire hazard or bodily injury.

Gas Supply Pressure: Minimum inlet gas supply pressure must be 4.5 in. W.C. for natural gas or 11 in. W.C. for LP gas for the purpose of input adjustment. Maximum inlet gas pressure must not exceed 7.0 in. W.C. for natural gas or 13 in. W.C. for LP gas. The gas line supplying the appliance must be sufficient size to furnish the appropriate supply pressure to the appliance while operating in the “High” setting. (Minimum line ID of 1/2 in. required if the line is longer than 20 ft.

Gas Line Pressure Test: Perform pressure test according to state and local code (if pressure exceeds 1/2 in. psi [3.5 kPa]) before appliance is connected. Be sure to release air pressure from the gas line before connection is made to the appliance. Excessive pressure will damage the gas control and may cause a gas leak.

Gas Leak Test: Make sure the gas connections are tight. Turn on the gas and coat each joint with a non-corrosive gas leak check solution. Air bubbles will form indicating any leaks. DO NOT USE A FLAME OR ANY TYPE OF IGNITION SOURCE TO CHECK FOR LEAKS. All leaks must be corrected before proceeding with installation.

WARNING

Shock Risk

Explosion Risk

Do NOT wire 110V to valve.

11

Quadra-Fire • Fogata Grande

Image 11
Contents What to do if you smell gas FG21SP-LPListing Label Information/Location CongratulationsTable of Contents Appliance Certification BTU SpecificationsListing and Code Approvals Asphyxiation Risk Design and Installation ConsiderationsGetting Started Tools and Supplies NeededInspect the Appliance and Components Valve Control Box AssemblyFire Risk Framing and ClearancesSelect Appliance Location ClearancesAppliance Set Up Quadra-Fire Fogata Grande Gas Connection Gas InformationFuel Gas PressureShock Risk Explosion Risk High Altitude Installations Valve Control Knob Piezo On/Off SwitchOperating Instructions Before Lighting ApplianceFor Your Safety Read Before Lighting After the Appliance is Lit Fire Risk High TemperaturesTroubleshooting TroubleshootingCheck Maintenance and Service TasksMaintaining and Servicing the Appliance Risk of injury or property damage Before servicing# Description of Part Part Number Qty Service Parts ListReference Materials Part Number Qty LogLogs # Description of PartLogs To obtain service under this warranty, you must
Related manuals
Manual 20 pages 34.69 Kb

FG21SP-LP specifications

The Quadra-Fire FG21SP-LP and FG21SP-NG are innovative gas stoves designed to enhance heating efficiency while providing an aesthetic charm to any living space. These models epitomize the ideal blend of contemporary design, quality engineering, and reliable performance, making them popular choices among homeowners seeking an effective heating solution.

One of the main features of the FG21SP series is its versatile fuel options. The FG21SP-LP operates on propane, while the FG21SP-NG is designed for natural gas. This flexibility allows users to select the fuel type that best suits their preferences and needs, ensuring a seamless integration into existing home systems.

Both models are equipped with a powerful 21,000 BTU capacity, providing ample heat for medium to large spaces. This heating output ensures that rooms maintain a comfortable temperature efficiently, especially during the colder months. The adjustable flame height allows users to customize the ambiance and heat output easily.

The stoves feature a unique bay front design, which offers a stunning view of the flames while maximizing the overall heat radiated into the room. The large viewing area is enhanced by the ceramic glass door, which is not only stylish but also durable and resistant to high temperatures.

Efficiency is a significant attribute of both the FG21SP-LP and FG21SP-NG models. With a high efficiency of up to 82%, these stoves convert a large percentage of fuel into usable heat, minimizing waste and reducing energy costs over time.

One of the standout technologies employed in these stoves is the Quadra-Fire’s innovative heat management system. This system ensures effective heat distribution while maintaining a steady and reliable performance. Additionally, both models come equipped with a variable-speed blower that enhances heat circulation, optimizing comfort throughout the space.

Maintenance is made simple with the FG21SP series, thanks to features such as easy access to the interior for cleaning and inspections. The attractive design, combined with the robust construction and user-friendly features, sets the Quadra-Fire FG21SP-LP and FG21SP-NG apart from other gas stoves in the market.

In conclusion, the Quadra-Fire FG21SP-LP and FG21SP-NG gas stoves deliver on performance, efficiency, and aesthetic appeal, making them excellent choices for anyone looking to upgrade their home heating system. With their modern design and array of features, these stoves not only provide warmth but also serve as beautiful focal points in any room.