Quadra-Fire DV-40 manual Safety Notices, Ansi NFPA-70

Page 4

SAFETY NOTICES

This stove should be installed only by a qualified installer. It is approved for installation in a bedroom. Bedroom installation in Canada requires that stove be hooked to a thermostat. The stove must be electrically grounded in accordance with local codes, or the latest edition of the National Electric Code. If no local codes exist, this stove should be installed following the current codes:

CAN/CGA-B149.1

Natural Gas Installation Code

CSA-C22.2 No. 3

Canadian Electrical Code

ANSI Z223.1

National Fuel Gas Code

ANSI NFPA-70

National Electrical Code

Manufactured (mobile) home installation must conform to the manufactured home construction and safety standard (UL307B, Title 24 CFR, Part 3280), or when such a standard is not applicable, the standard for manufactured home installations (ANSI A225.1/NFPA 501A).

The control compartment, burner, and circulating air passageways MUST be kept clean and clear to allow for adequate combustion and proper operation. Provide adequate clearances around air openings and adequate accessibility clearance for service and operation. NEVER obstruct the openings of the stove or the vent termination on the exterior of the building. NEVER vent the stove to other rooms or buildings; this stove must be vented ONLY to the outside. During installation, be sure to maintain minimum clearances to combustibles, as shown on page 14. Always contact your local building department or fire department prior to installing this stove. If required, obtain a permit before installing, and have the completed installation inspected. Failure to do this could jeopardize your homeowner’s insurance.

The area around the stove MUST be kept free from combustible materials, gasoline and other flammable vapors and liquids. This stove is hot during operation, and should be located out of heavy traffic areas and away from furniture and draperies. Clothing or other flammable material should not be placed on or near the stove. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Children should not be left unsupervised in the room when this stove is in operation. Never place anything on or near the heater, the thermostat or remote control can turn the stove on at any time.

If any part of this stove has been under water, DO NOT USE it!! Immediately call a qualified service technician to inspect the stove, and to replace any part of the control system or any gas control which has been under water.

This stove should NOT be modified under any circumstances. Any parts removed for servicing must be replaced before operating this stove. Installation and repair should only be done by a qualified service technician. The stove and its venting system should be inspected and cleaned annually by a qualified service technician. More frequent cleaning may be necessary due to excess lint and dust from carpeting, bedding material, etc. Be sure to turn off gas valve and pilot before cleaning this stove.

Install at least one smoke detector on each floor of your home to ensure your safety. They should be located away from the gas stove and close to the sleeping areas. Follow the smoke detector manufacturer’s placement and installation instructions, and be sure to maintain regularly. Your local

fire department may provide assistance in selecting smoke detectors, or contact the Consumer Product

Safety Commission, Washington, D.C. 20207.

See additional Safety Notices on next page.

 

Page 4

Image 4
Contents For Your Safety What to do if YOU Smell GASTable of Contents DV-40 Step Safety Label Found on PULL-OUT on Back of StoveSafety Notices Ansi NFPA-70Safety NOTICES, SpecificationsListings Natural GAS PropaneDimensions LEG ModelDV-40 Step LEG Adapter Assembly Instructions Unpacking the StoveDV40 Step Pedestal Installation Instructions Remote Control Thermostat InstallationBlower Power Cord Planning Your Installation Duravent Simpson DURA-VENT Parts List Number DescriptionBasic Kits Clearances to Combustibles HOW to USE Vent Graph Safety Precautions for the Installer Installation PrecautionsVenting Instructions Venting Horizontal Installation N T E R Or HHW2 Remove siding from Beneath Standoff Horizontal Installation Using GS Series Pipe Vertical TerminationsShingles Overlap TOP Edge of Flashing Vertical Terminations Cathedral Ceiling Installation Installation Into a Class a Metal Chimney Installation Into AN Existing Masonry Chimney TOP Adapter Step GAS Line Connection Appliance installer High Altitude OperationGAS Conversion Instructions for LP and NG Valve Regulator TowerBurner Orifice Replacement Conversion INSTRUCTIONS,Log replacement Conversion InstructionsLighting and pressure testing LOG InstallationConversion INSTRUCTIONS, LOG Installation Finished LOG SET Shutter Adjustment First FireLighting Instructions Located on PULL-UP AT Left Rear of StovePressure Testing Maintenance Cleaning and Inspection of Venting SystemCleaning the Burner Tubes Glass CleaningBlower Cleaning AND/OR Replacement For ReplacementSchematics Snap Disc Replacement Rear Heat ShieldAccessories Replacement PartsPilot Replacement Instructions Flame Troubleshooting FIG. aFlame Troubleshooting, Restrictor StrapTall Stringy Flame Single tall flame Many tall flamesPilot Troubleshooting Pilot Assembly Showing Flame Properly Adjusted GAS Stove Limited Lifetime Warranty For Your Records

DV-40 specifications

The Quadra-Fire DV-40 is a high-efficiency direct vent gas fireplace known for its advanced technology, aesthetic appeal, and superior heating capabilities. This versatile unit is designed to provide warmth and ambiance, making it an excellent addition to any home.

One of the standout features of the DV-40 is its direct vent system. This allows the fireplace to draw air from outside for combustion, ensuring that indoor air quality remains unaffected. This feature also makes the DV-40 a more efficient heating option, as it doesn’t deplete the oxygen levels inside the home. The balanced flue design means that the exhaust gases are vented outside while taking in fresh air, promoting a clean-burning operation.

With a BTU output ranging from 20,000 to 35,000, the DV-40 can effectively heat various spaces, making it suitable for different room sizes. Its ability to maintain consistent warmth adds to the comfort of any living environment. This unit also boasts an impressive thermal efficiency rating of up to 83 percent, translating to lower energy costs and reduced environmental impact.

The DV-40 features an aesthetically pleasing flame that can be customized according to the homeowner's preference. It offers a range of decorative options including ceramic logs, glass media, and stone, allowing users to create a unique and inviting focal point in their living room. The fireplace can be controlled via a convenient remote control that allows users to adjust heat settings and ignite the flames effortlessly.

From a safety perspective, the DV-40 incorporates advanced features such as a glass front that remains cool to the touch, ensuring peace of mind for families with children and pets. The unit is also equipped with a built-in safety shutoff system that triggers in the event of an overheating scenario.

In addition to its impressive performance and safety features, the Quadra-Fire DV-40 is designed for durability and ease of maintenance. Its robust construction ensures longevity while requiring minimal upkeep. The fireplace also adheres to various industry standards, providing assurance to consumers regarding its quality and safety.

In conclusion, the Quadra-Fire DV-40 combines modern technology, efficiency, and style. With its direct vent system, customizable aesthetic options, and superior heating capabilities, it stands out as an exceptional choice for homeowners looking to enhance their indoor spaces. Whether for cozy family gatherings or quiet evenings at home, the DV-40 is designed to deliver both function and elegance.