Temperature and Humidity Ranges
If you check the following tables, you can use your air conditioner more efficiently.
If the air conditioner is used at... Then...
Heating capacity | The air conditioner may stop operating for the reason of protection. | ||
|
| ||
Low temperatures | Water may leak and some malfunction may occur if the heat exchanger freezes. | ||
|
| ||
Protection mechanism | Water may condense and drip from the surface of the indoor unit if you don’t use | ||
the air conditioner for an extended period of time. |
| ||
|
| ||
|
|
|
|
|
|
|
|
Operation | Outdoor Temperature | Indoor Temperature | Indoor Humidity |
|
|
|
|
Heating | 27°C or less | - | |
Cooling | 16°C to 32°C approx. | 80% or less | |
Dehumidifying | 16°C to 32°C approx. | - |
If the outdoor temperature is as low as 0°C, the heating capacity drops up to 70~80% depending on the operating condition.
If you use the air conditioner in temperatures over 32°C (indoor temperature), the cooling capacity may drop.
Operating Recommendations
When you use your air conditioner, it is recommended that you read the following:
Topic | Recommendation |
|
|
|
|
Common | Airconditioner should be used only in the single closed room. Effective airconditioner operation |
|
| can be guarantee if all windows and doors in the room are closed. |
|
|
|
|
Heating capacity | The heat pump inside the air conditioner absorbs heat from outside air and brings itindoors. |
|
| If the temperature of the outside air drops, the air conditioner heats less. If the room is not warm |
|
| enough, use an additional heating appliance. |
|
|
|
|
Warm air circulation | The air conditioner circulates warm air to heat your room. It will take some time to warm |
|
| the air in your room entirely after the air conditioner turns on. |
|
| Therefore, turn the air conditioner on in advance. |
|
|
|
|
Frost | When you select the Heat mode, frost may form in the outdoor unit due to low temperature |
|
| and high humidity. |
|
| If this happens: |
|
| The heating operation is stopped. |
|
| The air conditioner defrosts automatically for about 7 minutes. After about 7 minutes, |
|
| the air conditioner starts operating again normally. |
|
|
|
|
High indoor and | If both the indoor and outdoor temperatures are high when you select the Heat mode, |
|
outdoor temperatures | the fan and the compressor of the outdoor unit may stop periodically. |
|
| This is normal; wait until the air conditioner turns on again. |
|
|
|
|
Power failure | If a power failure occurs when the air conditioner is operating, the air conditioner will turn off. |
|
| When the power returns, the air conditioner will start up again automatically. |
|
|
|
|
Protection mechanism | When the air conditioner is started immediately after being plugged in or stopped, |
|
| the normal operation starts up after 3 minutes for the reason of protection. |
|
|
|
|
Cooling operation | TheindoorunitmaynotgettheselectedfanspeedsuchasMediumandLowundercoolingoperationatverylow |
|
| outdoortemperaturesfortheprotectionoftheindoorunitfromiceorfrost. |
|
| DuringLowfanspeedoperation,coolingperformancewillbereduced. |
|
| IftheroomdoesnotbecooleddownwhenusingLowfanspeedoperation,pleaseadjusttheindoorunit’sfanspeed. |
|
|
|
|
Silence Mode | When you operate Silence Mode in cooling and heating, fan speed will decrease to make noise quieter. | |
| As a result, the performance of the unit may be reduced. | |
|
| |
|
|
|