Unpacking

1.With packaged unit on the floor, carton arrows should point upward.

2.Carefully remove staples from top of carton and fold back sides.

3.Carefully remove cabinet from carton by lifting out unit using finger holes in styrofoam side inset and place on work surface.

CAUTION: Do not attempt to lift this air curtain by its louver or damage may result.

4.Unscrew six (6) knurled nuts and remove air intake grille. (See Figure 3.)

5.Carefully disconnect motor electric cord and heater plug assembly and remove two wing nuts on blower base. (See Figure 4.)

STYROFOAM

SUPPORT

BLOCK

Figure 4 - Removing Motor/Blower Assembly

NOTE: Unit is shipped with styrofoam motor support block which must be discarded at this time.

6.To remove motor/blower assembly, lift from rear of motor housing to prevent damage and mis-alignment

to shaft and blower wheels.

NOTE: After unpacking unit, inspect carefully for any damage that may have occurred during transit. Check for loose, missing or damaged parts.

Figure 3 - Removing Air Intake Grille

General Safety Information

WARNING - TO REDUCE THE RISK OF FIRE, ELEC- TRIC SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the man- ufacturer. If you have questions contact the manufac- turer.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.

3.Installation work and electrical wiring must be done by qualified persons in accordance with all applicable codes and standards, including fire rated construction.

4.When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.

5.Make certain that the power source conforms to the

electrical requirements of the unit. Disconnect power before installing or servicing. If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of power. Failure to do

so could result in fatal electrical shock.

WARNING: DO NOT DEPEND UPON A THERMOSTAT OR OTHER SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE UNIT. ALWAYS DISCONNECT POWER AT THE MAIN CIRCUIT BREAKER AS DESCRIBED ABOVE. FAILURE TO DO SO COULD RESULT IN FATAL ELECTRIC SHOCK.

6.All wiring should be done by a qualified electrician, using copper wire only and in accordance with the National Electrical Code (NEC), all applicable code

and ordinances, and all sections of this manual. Any variance voids the warranty and may create unsafe conditions.

7.Special attention must be given to any grounding information pertaining to this product. To prevent the

risk of

electrocution, the unit must be securely

and a d e q u a t

ely grounded. This should be

accomplished by

connecting a

grounded conductor between the service

panel and the grounding lug or green leadwire provided in the wiring compartment. To ensure a proper ground, the grounding means must be tested

by a qualified electrician.

8.Do not insert fingers or foreign objects into the air curtain. Do not block or tamper with it in any manner while it is in operation. Do not touch it while in opera- tion or just after it has been turned off, as some parts may be hot enough to cause injury.

9.This product must NOT be used in potentially danger- ous locations such as flammable, explosive chemical laden, or wet atmospheres.

10.Do not attach ductwork to this product or attempt to use it as a make-up air heater. Such use voids the warranty and may create unsafe conditions.

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS AIR CURTAIN WITH ANY SOLID STATE SPEED CONTROL DEVICE.

2

Image 2
Contents Specifications and Performance DescriptionUnpacking General Safety InformationConnecting a Risk Electrocution, the unit must be securelyInstallation Mount cabinet on wall and securely tighten hardwareMaintenance OperationLow voltage Verify correct wire size Troubleshooting ChartMotor speed setting on high Position toggle switch to low Obstruction to blower wheel Remove obstructionReplacement Parts Replacement Parts List For Air Curtain Cabinets Replacement Parts List For Heater UnitsLimited Warranty Model Heater Motor Number Voltage Watts BTU/HR AmpsGro So could result in fatal electrical shockRisk ShouldClass 1 wiring is required Using template provided, determine mounting locaKnockout, using a suitable knockout connected to Before wiring be sure that available power supplyPlace motor/blower assembly on workbench Volt models only Replacement Parts Description Replacement Parts for 208V 3-PH Heaters QTY Limited Warranty Order to obtain any needed repair or replacementE3606-1425HFD, E3609-1425HFD Unpacking Plug Operation Troubleshooting Chart Replacement Parts Description Replacement Parts for 230V 3-PH Heaters QTY Limited Warranty E6006-2525HFD, E6009-2525HFD Number Voltage Watts BTU/HR Amps SizeThis Run proper size copper power supply conductors from Electric heater is equipped with a step-down transformerOperation Troubleshooting Chart Replacement Parts Description Replacement Parts for 460V 3-PH Heaters QTY Limited Warranty

E4806-1125HFD, E4212-1125HFD, E4206-1125HFD, E4209-1125HFD, E3812-1125HFD specifications

Marley Engineered Products has made significant strides in the engineering and manufacturing of cooling solutions, particularly with its series of high-performance fan coil units. The E3612-1125HFD, E4812-1125HFD, E3809-1125HFD, E3606-1125HFD, and E3812-1125HFD models stand out for their robust features and cutting-edge technologies that cater to diverse applications in both residential and commercial settings.

One of the primary features of these units is their compact and efficient design, allowing for ease of installation in tight spaces while maximizing airflow and cooling efficiency. Each model is equipped with a state-of-the-art fan motor that operates quietly and efficiently, ensuring minimal noise disruption in environments where comfort is paramount. The inclusion of advanced motor control technologies also enables these units to adjust their speed dynamically based on cooling demands, further enhancing energy efficiency.

The E3612-1125HFD, in particular, is designed for versatile applications, making it suitable for a range of environments, from small office buildings to large retail spaces. Its high cooling output is paired with low energy consumption, ensuring that operational costs are kept in check. Similarly, the E4812-1125HFD model features an even larger capacity, ideal for commercial spaces that require robust cooling solutions without compromising on energy efficiency.

Another significant characteristic across all models is their use of environmentally friendly refrigerants, meeting the latest regulatory standards to minimize environmental impact. Additionally, these units are designed with durability in mind, utilizing high-quality materials that enhance their longevity and reliability under varying operational conditions.

Maintenance is also simplified in these Marley Engineered Products units, with easy access to components for cleaning and servicing, ensuring that they remain operational and efficient over their lifespan. The user-friendly designs allow building operators to perform routine checks without needing specialized tools.

In summary, Marley Engineered Products' E3612-1125HFD, E4812-1125HFD, E3809-1125HFD, E3606-1125HFD, and E3812-1125HFD models represent the pinnacle of modern fan coil unit technology. With features that focus on performance, efficiency, and sustainability, these units are poised to meet the demands of today's diverse cooling applications, ensuring comfortable and energy-efficient environments.