Marley Engineered Products 994 manual Hanging FAN Motor and Making Electrical Connections

Page 4

HANGING FAN MOTOR AND MAKING ELECTRICAL CONNECTIONS

Lift motor with ball hanger assembly attached and position into ball hanger bracket, making sure slot in ball hanger locks onto ball hanger bracket’s ball locking stud. Connect motor leads to 120V, 60 cycle supply wiring in accordance with FIgures 5 and 13. Connect ground wire from supply to green ground wire on top of ball hanger. The white lead from the motor is connected to the white supply wire. The black lead from the motor is connected to the black supply wire to permit fan operation. Both the black and blue fan motor leads are connected to the black supply wire when a light kit is to be installed, permitting both fan and light operation. (See Figure 5.) Note that connections should be made outside the canopy. In some cases, it may be necessary to splice additional wire to existing wiring in order to make connections.

a

CAUTION !

1.Electrical connections should be in accordance with the National Electrical Code and/or all local codes that may apply.

2.To avoid possibility of serious injury or electrical shock, the installer must disconnect the electrical circuit supplying power to the fan outlet box prior to installing the ceiling fan.

3.Damp location ceiling fans must be installed in a GFCI protected circuit.

Once the electrical connections have been made, carefully position the leads with the connections pointed upwards inside the canopy or outlet box. Position the ground wire (green and bare connected wires) and the white connected wires on one side of the outlet box and/or canopy; the black connected wires on the opposite. Slide the canopy up to the ceiling making sure the canopy mounting screw heads pass through the key-way slots. Rotate the canopy towards the narrow end of the key-way and tighten the canopy mounting screws. See Fig. 5 & 6.

FIG. 5

WHITE CONNECTED WIRES

FIG. 6

120V. 60HZ. SUPPLY

OUTLET BOX APPROVED

 

 

FOR FAN SUPPORT

 

 

CEILING MATERIAL

CEILING

 

 

 

GREEN & BARE FIELD

 

BLUE

WIRE (GND.) CONNECTION

 

BLACK CONNECTED

BALL HANGER BRACKET

CHECK DOWNROD

 

WIRES

BALL HANGER SET

 

MOUNTING HUB SET

 

SCREW

CANOPY MOUNTING

 

SCREWS

SCREWS

BALL HANGER

 

 

CANOPY IN DOWN

 

BALL HANGER DOWNROD

POSITION

 

DOWNROD MOUNTING HUB

MOTOR HOUSING

 

SET SCREWS

 

 

TOP COVER

 

 

 

FIG. 7

FLUSH WITH

CEILING

CANOPY MOUNTING

SCREWS

ASSEMBLE SWITCH CUP TO FAN

1.Connect the switch cup plug to the fans connector plug, taking care to align the guides in each part. This ensures proper electrical circuit connection (matching lead colors).

2.Remove one screw from the switch cup mounting plate, and loosen the remaining two screws.

3.Position the switch cup onto fan’s remaining two switch cup mounting plate screws and twist to latch cup in place. With cup latched at extreme ends of latching cutouts, replace and secure the removed screw into the switch cup mounting plate through the cup’s screw hole. Tighten the other two screws loosened in Step 2.

4.Reconnect the supply power to the fan circuit. Make sure fan’s pull chain switch is in the off position (hub is not turning) following connection of the power and prior to performing the next steps.

SWITCH CUP

MOUNTING PLATE

SWITCH CUP

SECURING SCREWS

FAN

SWITCH CUP

FAN PULL CHAIN

SWITCH

CONNECTOR

PLUGS

— 4 —

Image 4
Contents Chart SeriesInstalling FAN Ball Hanger Mounting Bracket Assembling Ball Hanger to Motor Assembly Hardware bagAssemble Switch CUP to FAN Hanging FAN Motor and Making Electrical ConnectionsBlade Assembly Instructions Do not AttemptFAN Operation Reversible OperationLubrication Light KitsGeneral Installation Options Option #1 Fan and light controlled at unitHOW to Order Repair Parts Important Facts about OUR Foam Packaging

994 specifications

Marley Engineered Products 994 is an innovative solution in the market for heating, ventilation, and air conditioning (HVAC) systems. Designed with cutting-edge technology and efficiency in mind, the 994 model is particularly recognized for its ability to provide reliable and uniform temperature control in a variety of environments.

One of the standout features of the Marley 994 is its fan-assisted convective heating design, which allows for quick and effective heat distribution throughout a space. This model is equipped with a high-performance fan that operates quietly and efficiently, significantly improving comfort levels in both residential and commercial settings. The fan's adjustable speed settings enable users to optimize airflow according to specific heating needs, making it a versatile choice for various applications.

In terms of technology, the Marley 994 incorporates advanced controls that enhance usability and efficiency. Its digital thermostat offers precise temperature management, allowing users to set and maintain their desired comfort levels effortlessly. The programmable timer feature provides added convenience, enabling users to schedule heating operations around their routine, thus saving energy and reducing operational costs.

The construction quality of the Marley 994 is another characteristic that sets it apart. It's designed with rugged materials to ensure durability and long-lasting performance, even in demanding environments. The unit is also lightweight and compact, which simplifies installation and integration into existing HVAC systems.

Moreover, the Marley 994 is engineered with safety in mind. It includes a variety of safety features, such as overheating protection and automatic shut-off mechanisms, to prevent accidents and ensure reliability during operation. This commitment to safety enhances its appeal for both homeowners and commercial facility managers.

Energy efficiency is a hallmark of the Marley 994, as it conforms to the latest energy standards and regulations. This model provides significant energy savings, which not only benefits users financially but also supports sustainability efforts.

Overall, Marley Engineered Products 994 combines high-performance heating capabilities with advanced technology, durable construction, and safety features, making it an exceptional choice for those seeking effective HVAC solutions. Its versatility and efficiency make it suitable for a wide range of applications, ensuring reliable comfort no matter the setting. As the demand for efficient heating solutions continues to rise, the Marley 994 stands out as a leader in the industry.