Marley Engineered Products E4206-1325HFD, E6009-2325HFD Unpacking, General Safety Information

Page 2

Unpacking

1.With packaged unit on the floor, carton arrows should point upward.

2.Carefully remove staples from top of carton and fold back sides.

3.Carefully remove cabinet from carton by lifting out unit using finger holes in styrofoam side inset and place on work surface.

CAUTION: Do not attempt to lift this air curtain by its louver or damage may result.

4.Unscrew six (6) knurled nuts and remove air intake grille. (See Figure 3.)

Figure 3 - Removing Air Intake Grille

5.Carefully disconnect motor electric cord and heater plug assembly and remove two wing nuts on blower base. (See Figure 4.)

STYROFOAM

SUPPORT

BLOCK

Figure 4 - Removing Motor/Blower Assembly

NOTE: Unit is shipped with styrofoam motor support block which must be discarded at this time.

6.To remove motor/blower assembly, lift from rear of motor housing to prevent damage and mis-alignment

to shaft and blower wheels.

NOTE: After unpacking unit, inspect carefully for any damage that may have occurred during transit. Check for loose, missing or damaged parts.

General Safety Information

WARNING - TO REDUCE THE RISK OF FIRE, ELEC- TRIC SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the man- ufacturer. If you have questions contact the manufac- turer.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.

3.Installation work and electrical wiring must be done by qualified persons in accordance with all applicable codes and standards, including fire rated construction.

4.When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.

5.Make certain that the power source conforms to the electrical requirements of the unit. Disconnect power before installing or servicing. If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of power. Failure to do

so could result in fatal electrical shock.

WARNING: DO NOT DEPEND UPON A THERMOSTAT OR OTHER SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE UNIT. ALWAYS DISCONNECT POWER AT THE MAIN CIRCUIT BREAKER AS DESCRIBED ABOVE. FAILURE TO DO SO COULD RESULT IN FATAL ELECTRIC SHOCK.

6.All wiring should be done by a qualified electrician, using copper wire only and in accordance with the National Electrical Code (NEC), all applicable code and ordinances, and all sections of this manual. Any variance voids the warranty and may create unsafe conditions.

7.Special attention must be given to any grounding information pertaining to this product. To prevent the

risk of

electrocution, the

unit must be securely

 

 

and

a d e q u a t ely

gro

unded.

This

should

be

 

accomplished by

 

 

 

 

connecting

a

grounded conductor between the service

 

 

 

 

panel and the grounding lug or

green

leadwire

 

 

 

provided in the wiring compartment. To ensure a proper ground, the grounding means must be tested by a qualified electrician.

8.Do not insert fingers or foreign objects into the air curtain. Do not block or tamper with it in any manner while it is in operation. Do not touch it while in opera- tion or just after it has been turned off, as some parts may be hot enough to cause injury.

9.This product must NOT be used in potentially danger-

ous locations such as flammable, explosive chemical laden, or wet atmospheres.

10.Do not attach ductwork to this product or attempt to use it as a make-up air heater. Such use voids the warranty and may create unsafe conditions.

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS AIR CURTAIN WITH ANY SOLID STATE SPEED CONTROL DEVICE.

2

Image 2
Contents Model Heater Motor Specifications and PerformanceDescription Number Voltage Watts BTU/HR AmpsGeneral Safety Information UnpackingInstallation Operation MaintenanceCleaning LubricationTroubleshooting Chart Symptom Possible Causes Corrective ActionReplacement Parts Key Replacement Parts List For Air Curtain CabinetsReplacement Parts List For Heater Units DescriptionHOW to Order Repair Parts Order to obtain any needed repair or replacement

E4806-1325HFD, E3606-1325HFD, E6006-2325HFD, E4209-1325HFD, E6009-2325HFD specifications

Marley Engineered Products is a recognized leader in the field of air movement and ventilation solutions. Their range of industrial fans and blowers delivers efficient cooling and heating solutions for various applications. Among their popular offerings are the E4206-1325HFD, E3806-1325HFD, E3809-1325HFD, E4806-1325HFD, and E4209-1325HFD models, each with distinctive features and technologies that cater to diverse operational needs.

The E4206-1325HFD fan is notable for its high-efficiency design, capable of delivering superior airflow while minimizing energy consumption. It incorporates a robust motor that ensures consistent performance in demanding environments. The design includes a corrosion-resistant housing, ensuring longevity even in challenging conditions, making it ideal for industrial applications.

On the other hand, the E3806-1325HFD model focuses on versatility and comes equipped with advanced sound-dampening technology. This feature ensures quieter operation, which is crucial for facilities where noise reduction is a priority. Additionally, this model is engineered for easy maintenance, with accessible components allowing for quick servicing without extensive downtime.

The E3809-1325HFD model stands out in terms of airflow capacity, delivering high volumes of air while remaining energy-efficient. Its aerodynamic blade design optimizes performance, ensuring that air is moved effectively across large spaces. This model is perfect for warehouses and manufacturing facilities that require powerful airflow to maintain optimal temperatures.

Moving on, the E4806-1325HFD is particularly recognized for its high-performance capabilities under extreme conditions. It features an advanced motor that operates efficiently at high speeds, ensuring robust airflow while remaining energy efficient. The fan's durable construction withstands harsh environments, making it suitable for industrial applications.

Lastly, the E4209-1325HFD combines multiple technologies to enhance its performance. It features a multi-speed motor, allowing users to adjust airflow based on specific requirements. This flexibility improves energy efficiency and operational effectiveness in varying scenarios. The fan’s compact design ensures it can be utilized in tight spaces without compromising performance.

In summary, Marley Engineered Products offers these fans as part of their commitment to quality, efficiency, and innovation. Each model is designed with distinct technologies and characteristics that address a wide array of heating and cooling needs across different industries.