STORAGE
Store the heater in a dry location free from fumes or dust.
At the end of each heating season, clean the heater as described in the MAINTENANCE section. Drain and flush the fuel tank with clean fuel. The manufacturer recommends completely filling the tank with fuel for extended storage to minimize condensation inside the tank.
SERVICING
A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:
•The flame is contained within the heater.
•The flame is essentially yellow.
•There is no strong disagreeable odor, eye burning or other physical discomfort.
•There is no smoke or soot internal or external to the heater.
•There are no unplanned or unexplained shut downs of the heater.
The parts lists and wiring diagram show the heater as it was constructed. Do not use a heater which is different from that shown. Heater performance is effected by air pressure setting. If there is any uncertainty about the air pressure setting, have it checked.
A heater which is not working right must be repaired, but only by a trained, experienced service person.
MODEL-MH50K
WIRING DIAGRAM
Mr. Heater Kerosene Forced Air Heater | 5 | Operating Instructions and Owner’s Manual |