Mr. Heater MHVFB10LP installation instructions Placing Heater on Mounting Bracket

Page 7

Placing Heater on Mounting Bracket

1.Locate two horizontal slots on back pane of heater (see figure 19).

2.Place heater onto mounting bracket. Slide hori- zontal slots onto stand-out tabs on mounting bracket.

Horizontal Slots

Mounting Bracket mounted to wall

Mounting Screws

Figure 9

Installing Bottom Mounting Screws

WARNING: This appliance requires a 3/8” NPT (National Pipe Thread) inlet connection to the pres- sure regulator.

CAUTION: Never connect heater directly to the Propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and Propane/LP supply.­

The installer must supply an external regulator. The ex- ternal regulator will reduce the incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure heater regulator dam- age could occur. Install external regulator with the vent pointing down as shown in Figure 12. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of larger enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.­

Installation must include an equipment shutoff valve, union and plugged 1/8” NPT tap. Locate NPT tap within reach of test gauge hookup. NPT tap must be up- stream from heater (see figure 12).

1.

Locate two bottom mounting screw holes.

 

These holes are near bottom on back panel of

 

heater (see figure 9).

2.

Mark screws locations on wall.

3.

Remove heater from mounting bracket.

4.

If installing bottom mounting screw into hol-

 

low or solid wall, install wall anchors. Follow

 

steps 1 through 4 under Attaching to Wall using

 

Anchor. If installing bottom mounting screw into

 

wall stud, drill holes at marked locations using

 

9/64” drill bit.

5.

Re-place heater onto mounting bracket.

6.

Place spacers between bottom mounting holes

 

and wall anchor or drilled hole.

7.

Hold spacer in place with one hand. With the

 

other hand, insert mounting screw through

3/8” NPT Pipe Nipple

Ground Joint Union

Equipment

Shutoff Valve

From Gas Meter (4” W.C. to 10.5” W.C. Pressure)

3” Minimum

Pressure

Regulator

Heater

Cabinet

Test Gauge

Connection

Tee Joint

Reducer Bushing to 1/8” NPT

1/8” NPT Plug Tap

Tee Joint

 

 

 

Pipe Nipple

Sediment

Trap

Cap

 

 

 

 

 

 

 

bottom mounting hole and spacer. Place tip of

screw in opening of wall anchor or drilled hole.

8. Tighten both screws until heater is firmly se-

cured to wall. Do not over tighten.

Note: Do not re-place front panel at this time. Re- place front panel after making gas connections and checking for leaks.

CONNECTING TO GAS SUPPLY FOR PERMANENT INSTALLATION

WARNING: A qualified service person must con- nect heater to gas supply. Follow all local codes.­

Figure 12

*A CSA/AGA certified equipment shutoff valve with 1/8” NPT tap is an acceptable alternative to test gauge con- nection. Purchase the CSA/AGA certified equipment shutoff valve from your dealer. See Accessories, page 17.

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater fuel train.

CAUTION: Use pipe joint sealant that is resistant to LP-Gas

Install sediment trap in supply line as shown in figure 12. Locate sediment trap where it is within reach for

Unvented LP-Gas Fired Buddy Wall-Mount Heater

7

Installation Instructions and Owner’s Manual

Image 7
Contents MR. Heater Carbon Monoxide Poisoning PrecautionsPropane/LP Gas Unpacking Safety DeviceLocal Codes Ignition SystemVentilation from Inside Building Ventilation AIRVentilation from Outdoors Fastening Heater to Wall Installation Check GAS TypeFor Permanent Installation Locating HeaterAttaching to Wall Stud Placing Heater on Mounting Bracket Connecting to GAS Supply for Permanent InstallationTest pressure in Excess of ½ psig 3.5kPa Pressure Testing Heater Gas ConnectionsLighting Instructions For Your Safety Read Before LightingPilot Flame Pattern Cleaning and MaintenanceTo Turn OFF GAS to Appliance Inspecting BurnerCleaning Burner Pilot AIR Hole Inlet SpecificationsObserved SYMPTOM­ Possible CAUSE­ REMEDY­ TroubleshootingObserved SYMPTOM­ Possible CAUSE­ REMEDY­ Troubleshooting CON’TParts List Page Ansi Z21.11.2b-2004 Warranty Information

MHVFB10LP specifications

Mr. Heater MHVFB10LP is a powerful and efficient portable propane heater designed for optimal performance in a variety of outdoor and indoor applications. This innovative heating solution is ideal for individuals looking to warm large spaces, such as garages, workshops, and various outdoor events. With its user-friendly design and advanced technology, the MHVFB10LP delivers both comfort and convenience.

One of the standout features of the MHVFB10LP is its impressive heating capacity, providing up to 10,000 BTUs of heat. This output can effectively warm areas up to 225 square feet, making it an excellent choice for both small and moderately sized spaces. The heater has a high-efficiency rating, achieving a 99.9% fuel efficiency, which ensures that users get the most out of their propane supply.

The MHVFB10LP is equipped with an adjustable heat setting, allowing users to customize their heating experience as needed. Whether you need a gentle warmth or a significant boost in temperature, this heater can easily accommodate your requirements. Additionally, the radiant technology utilized in this heater provides warm, even heat across the given space, ensuring a comfortable environment.

Safety is paramount when it comes to heating solutions, and Mr. Heater has incorporated various safety features into the MHVFB10LP. The heater is designed with an automatic shut-off feature that activates if the unit is tipped over or if it detects a low oxygen level. This provides peace of mind for users, allowing them to focus on enjoying their space without undue concern.

The portability of the MHVFB10LP is another noteworthy characteristic. Weighing in at a manageable size, the unit features a convenient carrying handle, allowing users to easily transport it from one location to another. This makes it ideal for camping trips, tailgating events, and workshops alike.

Furthermore, the MHVFB10LP is designed for easy operation, featuring an integrated piezo igniter that allows for quick starts without the need for matches or lighter fluid. This ensures that users can enjoy warmth almost instantly.

In summary, the Mr. Heater MHVFB10LP is a versatile, efficient, and safe propane heater that meets the heating needs of a wide array of users. From its powerful heating capacity and adjustable settings to its safety features and portability, the MHVFB10LP stands out as an essential tool for comfort in both work and leisure activities. Whether you’re looking to ward off the chill on a cold day or need a reliable heat source for your outdoor adventures, this heater delivers exceptional performance.