Mr. Heater MH25LP / MH25NG Chapter Operator Maintenance Instructions, Troubleshooting, Inlet

Page 12

CHAPTER IV

OPERATOR MAINTENANCE

INSTRUCTIONS

1. TROUBLESHOOTING

A.Table 4 lists the common malfunctions which you may find during the operation or maintenance of your heater.

B.For additional information, refer to Honeywell Field Bulletin enclosed in the heater carton.

C.In the event results cannot be obtained after performing all listed solutions, call the factory.

2. ADJUSTING THE PILOT FLAME

The pilot flame should envelop 3/8 to 1/2 in. (10 to 13

mm)of the tip of the thermocouple or generator. Refer to Figure 11. To adjust:

PROPER FLAME

ADJUSTMENT3/8 TO 1/2 INCH (10-13 MILLIMETERS)

THERMOCOUPLE

Figure 11. Proper Flame Adjustment

A.Remove pilot adjustment cover screw. Refer to Figure 12.

B.Turn inner adjustment screw clockwise to

decrease or counterclockwise to increase pilot flame.

C.Always replace cover screw after adjustment and tighten firmly to ensure proper operation.

 

PRESSURE REGULATOR ADJUSTMENT

 

MANUAL GAS

(BENEATH COVER SCREW)

INSTALL LONG

 

CONTROL KNOB

 

SCREW IN

WRENCH

 

OUTSIDE CORNER

 

 

BOSS

 

 

 

STANDARD

 

 

PRESSURE

 

 

REGULATOR

 

 

(“A” MODEL)

 

GAS

STEP OPENING REGULATOR

(“C” MODEL)

INLET

 

 

PILOT GAS OUTLET

 

(PRESSURE TAPPING

 

DIRECTLY BENEATH)

PILOTSTAT

PILOT FLOW ADJUSTING SCREW

POWER UNIT

(BENEATH COVER SCREW)

Figure 12. Top View of Standard Capacity Gas Control

Model # MH25NG/LP

HS25NG/LP

12 Installation instructions and Owner’s Manual

Image 12
Contents GAS Fired INFRA-RED Workshop Heater What to do if YOU Smell GASTable of Contents Chapter Introduction EquipmentPurpose of Equipment Models Covered in this ManualHeater Dimensions and Orifice Sizes General InformationBTU Ratings and Supply Pressures NfpaChapter Heater Installation General Installation Information and RequirementsOnly Flue Side of Heater can be Elevated 30o Heater Side Reflector Must be HorizontalHeater Mounting Instructions Heater Mounting Information Connecting Heater to GAS Supply Piping InstallationGas Supply Requirements Piping RequirementsTypical Piping Installation Operating Safety Instructions Heater Startup Chapter Heater Operating InstructionsPressure Heater Shutdown Lighting of Pilot BurnerChapter Operator Maintenance Instructions TroubleshootingAdjusting the Pilot Flame InletSymptoms Causes Solutions Replacing the GAS Valve UnitFrequency of Operator Checks Gas control knob Is hard to turn or push down, orIf Service is Required Chapter Replacement Parts ListPlease do not Return this Appliance to Your Store ALL Warranty Claims Require Proof of Purchase Keep this warranty Can 1-2.16-M81 Ansi Z83.6b-19931993-6b.Z83 Ansi M81-16.2-1 canGarantie cette Conservez Clature Description Nomen DE N ’ARTICLE N Rechange DE Pièces DES Liste V Chapitre Nécessaire EST Réparation UNE SIMagasin Votre À Appareil CET PAS Retournez NE GAZ DE Soupape LA DE Remplacement Solutions Causes SymptômesSi remplacée être doit gaz de commande La ’UTILISATEUR PAR Inspections DES FréquenceFlamme La de approprié Réglage .11 Figure DépannageVeilleuse la de Allumage .10 Figure Radiateur DU ArrêtDu dissipation la permettre pour minutes 5 Attendez Remarque Manuelle GAZ DE Commande DE Bouton Radiateur DU D’UTILISATION Notice III ChapitreGaz de soupape la de Composants .9 Figure Sécurité DE ConsignesTuyauterie la de type Installation .7 Figure Cm 7,6Câblage de Schéma .4 Figure Joint À Pâte DE Modérée Quantité UNE UtilisezGAZ EN L’ALIMENTATION À Radiateur DU Connexion Radiateur du montage de Directives .3 Figure Figure LA VoirRadiateur DU Montage DE InstructionsRadiateur DU Installation II Chapitre Relativement Exigences ET Généraux RenseignementsPuissance Orifices des tailles et radiateur du Dimensions .2 Tableau ’alimentation pressions et BTU en Puissances .1 TableauGénéraux Renseignements NfpaIntroduction I Chapitre Guide DU UtilisationGuide Présent LE Dans Décrits Modèles ’ÉQUIPEMENT DE UtilisationMatières DES Table Garde EN MiseCarbone de monoxyde au Empoisonnement AvertissementsGAZ AU Alimenté Infrarouge À Telier D’ Teur Radi a GAZ DE Odeur D’UNE Présence EN

MH25LP / MH25NG specifications

The Mr. Heater MH25LP and MH25NG portable heaters are designed for anyone looking to efficiently heat small to medium-sized spaces, whether indoors or outdoors. These heaters are known for their reliability and effectiveness, making them popular choices for residential use, outdoor activities, and emergency heating scenarios.

The MH25LP is the propane model, while the MH25NG utilizes natural gas, providing versatility in fuel options to cater to different preferences and availability. Each unit is fitted with essential safety features, including an oxygen depletion sensor and an accidental tip-over shutdown system, ensuring peace of mind during use.

One of the main features of the Mr. Heater MH25 series is its impressive heating capacity. The units can produce up to 25,000 BTU per hour, sufficient for heating spaces up to 600 square feet, making them ideal for workshops, garages, cabins, and various outdoor activities. The adjustable heat settings allow users to customize the temperature to suit their comfort level, maximizing efficiency and reducing fuel consumption.

The design of the MH25 heaters emphasizes user convenience. Both models are lightweight and portable, which allows for easy transportation from one location to another. They come equipped with comfortable carrying handles, enhancing their usability for outdoor events, camping trips, or simply moving from room to room.

Another significant feature of the Mr. Heater MH25 series is the sophisticated combustion technology employed. The heaters utilize a radiant heating system that effectively warms objects and people in the room rather than just the air, leading to faster heating times and a more comfortable environment. Additionally, the units are designed with a sturdy and durable construction that ensures longevity, withstanding the rigors of outdoor use.

The units are also designed to operate quietly, making them an excellent choice for environments where noise levels need to be kept to a minimum, such as in personal workshops or while camping.

Overall, the Mr. Heater MH25LP and MH25NG are powerful, safe, and portable heating solutions that provide reliable warmth and comfort in various settings. Their combination of efficient heating, portable design, and safety features makes them an essential tool for anyone needing reliable heating solutions. Whether for everyday use or special events, these heaters stand out as dependable options to keep warm.