Napco Security Technologies GEM-DXRP3 Programming User Codes, Entering the User Program Mode

Page 22

PROGRAMMING USER CODES

Your Installer has programmed into your system a special User Program Code which can be used to not only Arm and Disarm the system, but also to enter the User Program Mode, where you can program other User Codes. The following explains how you will use this code to program or erase additional User Codes.

Entering the User Program Mode

1Enter your User Code, then press Ato enter the Function Mode.

2Answer NO (press F) until “17” (Activate Program) is displayed, then press YES (E) .

The display will scroll the following: “P” (Program mode); 4 digits identifying software versions; then “UP” (User Program). The keypad lights will flash while in the User Program Mode.

Programming / Reprogramming a User Code

1Press A, followed by the the 2 digits of the user number to be programmed ( Example: for User 4, enter 04).

2Press A, followed by the new User Code. Note: User Codes may be up to 6 digits in length. For User Codes shorter than 6 digits, use G0for remaining digits.

3Press Arepeatedly until “UP” is displayed.

4Press J to save the new User Code. Note: Duplicate Codes are not allowed; therefore a duplicate Code entered in the LCD

Window will erase when J is pressed. Repeat Steps 1 through 4 for each User Code to be programmed.

Erasing a User Code

To erase a User Code, press A, the 2-digit user number, Afollowed by G0until “UP” is displayed, then J.

Example: Erase User 3’s User Code:

Press A03AG0G0G0G0G0G0(“UP” will display) J.

Reviewing a Programmed User Code

To review a User Code, press A, the 2-digit user number and Ato step through and review each digit of code.

22

Image 22
Contents GEM-DXRP3 Keypad Introduction Important Test Your System WeeklyTable of Contents Keypad Controls & Indicators Numerical Keys 1-9, 0. Used to ButtonArea Button G. Selects Emergency Buttons. OptionalPriority Arming Setting the Alarm Arming When LeavingArming the System Selectively Bypassing ZonesManagers Mode Area Arming OptionalBypassing Interior Zones Protecting Yourself While on the PremisesInstant Protection ‰ Press D to activate Easy Exit on your system Alarm Indication / Silencing an Alarm Turning OFF the AL ARM Disarming When ReturningDisarming the System Fire Protection Fire-Zone TroubleFamily Rehearsal Preparing a Fire Escape PlanImportant! Read Carefully Floorplan Limitations of Fire Alarm Warning System Keypad Functions System troubles. For GEM-P9600/3200 panels only Keypad Functions Keypad Functions Keypad Functions Communicator Features Central Station MonitoringExit-Delay Restart Advanced FeaturesSecurity Bypass/Unbypass Programming / Reprogramming a User Code Entering the User Program ModeProgramming User Codes Erasing a User CodeExiting the User Program Mode Programming ExampleGlossary Closing Window Optional. aMore up to eight independent subsystems areas Glossary System Trouble Error Codes Trouble System Trouble Action Indication Condition06-NN 12-NN E19-00 Troubleshooting What do I do if For more infoNapco Limited Warranty Without charge to the original purchaser or user

GEM-DXRP3 specifications

Napco Security Technologies has established itself as a key player in the security industry, and one of its most notable offerings is the GEM-DXRP3 control panel. This versatile and user-friendly security system is designed for residential and commercial applications, delivering exceptional performance and reliability.

The GEM-DXRP3 operates as a wireless security system, leveraging advanced radio frequency (RF) technology to provide seamless communication between the control panel and peripheral devices. This eliminates the need for extensive wiring, making installation quicker and less disruptive, and allows for greater flexibility in terms of device placement. Its range of up to 2,500 feet in open areas ensures comprehensive coverage, accommodating diverse property layouts.

One of the standout features of the GEM-DXRP3 is its compatibility with a broad array of sensors and detectors. The system supports various devices, including door/window contacts, motion detectors, and glass break sensors, allowing users to tailor their security setup to their specific needs. Utilizing Napco's proprietary sensor technology, the panel ensures reliable detection and minimal false alarms.

The GEM-DXRP3 is equipped with a built-in keypad, providing users with easy access to system functions. This intuitive interface simplifies arming and disarming processes and enables quick adjustments to settings. Additionally, the system supports remote monitoring capabilities, allowing users to control and manage their security setup from virtually anywhere, enhancing convenience and peace of mind.

Another significant characteristic is its integrated Z-Wave technology, which adds home automation features. Users can control compatible smart devices, such as lights and thermostats, directly from the security panel or remotely via a mobile app. This integration not only enhances security but also improves energy efficiency and overall home convenience.

The GEM-DXRP3 is designed with scalability in mind. It accommodates a variety of expansion modules, allowing users to increase their security capacity as needed. This makes it an ideal solution for both small residential properties and larger commercial sites.

Durability and reliability are hallmarks of the GEM-DXRP3. With robust hardware and advanced firmware, the system is built to withstand various environmental conditions while providing consistent performance. Whether you're looking to secure a home or a business, Napco Security Technologies' GEM-DXRP3 remains a top choice, combining advanced features, ease of use, and reliability for superior security management.